Fluke 707Ex Искробезопасный калибратор петли тока
Выпуск прекращен
Ключевые особенности
- High performance intrinsically safe loop calibrator for use in potentially explosive environments
- Is certified in accordance with ATEX directive (Ex II 2 G Ex ia IIC T4) in Zones 1 and 2 and to operate in accordance with Factory Mutual N.I. Class 1, Division 2 areas Group A-D
- Features large display and simple, quick-click interface for easy one-handed operation
Эта продукция снята с производства
Fluke рекомендует:Fluke 707 Калибратор петли тока
Обзор прибора: Fluke 707Ex Искробезопасный калибратор петли тока
The fast one-handed tool for mA loop checks in Ex zones
The 707Ex is an intrinsically safe loop calibrator for use in explosion endangered areas. The Fluke 707Ex is certified in accordance with the ATEX directive (Ex II 2 G Ex ia IIC T4) in Zones 1 and 2.
Характеристики: Fluke 707Ex Искробезопасный калибратор петли тока
Specifications | ||
Current measurement | Range | 0 to 24 mA |
Resolution | 0.001 mA | |
Accuracy | 0.015% Rdg + 2 LSD | |
Current sourcing | Range | 0 to 20 mA or 4 to 20 mA |
Accuracy | 0.015% Rdg + 2 LSD | |
Drive capability | 700 Ω at 20 mA | |
Current simulation | Range | 0 to 20 mA or 4 to 20 mA |
Accuracy | 0.015% Rdg + 2 LSD | |
Loop power | While measuring mA, 24 V | |
Voltage measurement | Range | 0 to 28 V DC |
Resolution | 1 mV | |
Accuracy | 0.015% Rdg + 2 LSD | |
Environmental Specifications | ||
Operating temperature | -10ºC to 55ºC | |
Storage temperature | -40ºC to 60ºC | |
Humidity (without condensation) | 0 to 95% (0ºC to 30ºC); | |
0 to 75% (30ºC to 40ºC) | ||
0 to 45% (40ºC to 50ºC) | ||
Temperature coefficient | -10ºC to 18ºC, 28ºC to 55ºC, ±.005% of range per ºC | |
Safety Specifications | ||
Safety | CSA C22.2 No. 1010.1:1992 | |
EMC | EN50082-1:1992 and EN55022:1994 Class B | |
Maximum voltage | 30 V | |
ATEX certification | Ex II G Ex ia IIC T4 Zones 1 and 2, ZELM 02 ATEX 0120 X | |
CE certification | EN61010-1 and EN61326 | |
Mechanical and General Specifications | ||
Size | 152 x 70 x 41 mm | |
Weight | 224 g (350 g including holster) | |
Batteries | One 9V battery Alkaline | |
Warranty | 3 year | |
Shock & vibration | per MIL-T-28800 for a Class 2 Instrument | |
Display current and % of span | Yes | |
Auto step, auto ramp | Yes | |
Span check | Yes |
Модели: Fluke 707Ex Искробезопасный калибратор петли тока
Fluke 707Ex
Fluke 707Ex Intrinsically Safe Loop Calibrator
Includes:
- Alligator test clips
- Instruction manual (on CD-ROM)
- Protective holster with Flex-Stand™
- Safety designed test leads
- NIST- traceable calibration report and data
Руководства + Ресурсы: Fluke 707Ex Искробезопасный калибратор петли тока
- 707Ex | Руководство по эксплуатации
- 707Ex | Приложение к Руководству по эксплуатации
- 707Ex | Руководство по калибровке
- 707Ex | Приложение к руководству по калибровке
- 707Ex | Положение об энергозависимости памяти
- 707Ex | Паспорт безопасности
- 707Ex | Приложение к паспорту безопасности
- 707Ex CCD | Контрольные схемы