RPM4基準圧力モニター

  • RPM4 Reference Pressure Monitor

主な機能

  • 頑丈な近傍精密基準圧力モニター。読み取りの +/- 0.008 % という優れた不確実さ
  • 独立した水晶振動式基準圧力トランスデューサー・モジュール (Q-RPT) と個別の自己防御システム (SDS™)
  • 15 kPa (2.2 psi) 複合ゲージから最大 280 MPa (40,000 psi) のレンジ
  • RS232 および IEEE-488 通信、バッテリ・パックを利用可能。
  • 簡単な無償のフラッシュ・メモリを搭載

製品概要: RPM4基準圧力モニター

RPM4 Reference Pressure Monitor is different from traditional pressure monitors. State-of-the-art performance from very low pressure to 280 MPa (40,000 psi)… advanced on-board features… compact and rugged… full local and remote communications… RPM4 is the perfect solution in a wide variety of high end pressure calibration, testing and measurement applications.

Infinite Ranging™ and AutoRange™


Infinite Ranging gives RPM4 Reference Pressure Monitor unprecedented versatility in adapting to the specific range of operation. With the easy-to-use AutoRange function, a few simple key strokes or a single remote command string at the start of a test adapt every feature of the pressure monitor to optimize it for the range to be covered. Just enter the maximum pressure and the measurement mode. AutoRange then:

  • Selects and activates the most appropriate Q-RPT to cover the specified range and measurement mode.
  • Sets the pressure unit of measure. • Activates absolute, gauge or compound gauge measurement.
  • Adjusts display resolution to the appropriate level for the range.
  • Adjusts overpressure alarms to the actual range of operation.
  • Reduces measurement uncertainty proportionally to the selected range (premium class Q-RPTs only).


Note: The use of RPM4’s Infinite Ranging and AutoRange feature is recommended to optimize operation for a specific range but is not required to obtain “% of reading measurement specifications.

SDS™ Q-RPT self defense system


All Q-RPT modules up to 7 MPa (1 000 psi) include the unique Self Defense System™ (SDS). SDS valves automatically isolate and vent the module's Q-RPT when it is not in use or an overpressure is about to occur. With SDS, any Q-RPT module can be left connected to pressure up to 10 MPa (1 500 psi) without needing to isolate or disconnect it.

Advanced on-board functions


RPM4 pressure monitors provides a variety of advanced on-board pressure data functions including:

  • Special data such as pressure average over time, rate of change, hi/lo, freeze, deviation from set point.
  • Differential mode directly measures the difference between two Q-RPTs including taring at the line pressure.
  • Parallel measurement uses two Q-RPTs redundantly as one.
  • Leak check measures average pressure rate of change over a user set time period.
  • AutoTest automates calibration routines with tolerance testing and data logging.

Quartz reference pressure transducer (Q-RPT) modules


RPM4's outstanding pressure measurement specifications are made possible by Fluke Calibration’s exclusive quartz reference pressure transducer (Q-RPT) modules.

Q-RPTs measure pressure by measuring the change in the natural oscillating frequency of a quartz crystal with pressure induced stress. To be qualified for use in a Q-RPT module, each transducer is individually evaluated and characterized using primary pressure standards. Only transducers exhibiting required levels of linearity, repeatability and stability are selected. A proprietary compensation model, derived from more than 15 years experience with thousands of quartz pressure transducers, is applied to optimize the metrological characteristics needed in a transfer standard. Standard and premium class Q-RPT modules are available to best fit your performance and budgetary requirements.

A unique dynamic compensation for atmospheric pressure system uses an independent on-board barometer to provide seamless switching between absolute, gauge and compound gauge modes at any time. The barometer is used only to measure the small variations in atmospheric pressure that occur during gauge mode operation so its absolute error and drift over time do not contribute to measurement uncertainty. Q-RPT modules offer the advantages of:

  • % of reading measurement uncertainty with AutoRange span turndown available
  • Negligible warm up time
  • No gas species dependence
  • Quartz element isolated from test medium
  • Low sensitivity to orientation


Q-PRTs and ranges

 


Q-RPT Designation

SI Version

US Version

Measurement MODE(s) Supported

Operating Media

SDSTM Self Defense System
 Maximum Range [kPa] Absolute Maximum Range [kPa] Gauge Maximum Range [psi] Absolute Maximum Range [psi] Gauge
A280M-L280 000280 00040 00040 000
Absolute, Gauge and Compound Gauge

Gas Stndard
Oil available

Not available
A200M-L200 000200 00030 00030 000
A140M-L140 000140 00020 00020 000
A100M-L100 000100 00015 00015 000
A70M70 00070 00010 00010 000
Gas Standard
Oil available
 Gas only
A40M40 00040 000 6 000 6 000
A20M20 00020 000 3 000 3 000
A14M14 00014 000 2 000 2 000
A10M10 00010 000 1 500 1 500
Included
A7M7 0007 000 1 000 1 000
A3.5M3 5003 500 500 500
Gas only
A2M2 0002 000 300 300
A1.4M1 4001 400 200 200
A700K700700 100 100
A350K350250 50 35
A200K200100 30 15
A160K16060238
A100K11010 16 1.5
BA100K1110
--- 
16
---
G200K
---
200 
---
30
Gauge only
G100K
---
100 
---
15
BG15K2
---
15 
---
2.2
G15K
---
15 
--- 
2.2


1 BA100K is a barometer with a low point of 70 kPa (10 psia).
2 BG15K is bidirectional gauge from - 15 to + 15 kPa (- 2.2 to + 2.2 psi).

Compatible with PPC4 Automated Pressure Controller


RPM4 can be used as an external reference pressure measurement device for a Fluke Calibration PPC4, fully automated, pressure controller/calibrator. One RPM4 can be connected to PPC4 by 9-pin RS232 cable. The RPM4's Q-RPT(s) become part of the PPC4 system and are managed by the PPC4 transparently to the user. There is only one test connection for the PPC4 system's full range of operation.

仕様: RPM4基準圧力モニター

General
Power supply specifications85-264 VAC, 50/60 Hz,
up to 25 VA and 12 VDC @ 9 Ahr
Battery Charger:100-240 VAC, 50/60 Hz 
Standard operating temperature range15-35 ° C
vibrationCompatible with MIL-T-28800D
Weight (typical value)5 kg (11 lb)
SizeHeight 10 cm x Width 22.7 cm x Depth 24 cm (3.9 in x 8.9 in x 9.5 in)
Battery Charger:Height 8 cm x Width 22.5 cm x Depth 20 cm (3.1 in. X 8.9 in x 7.9 in)
Communication portRS232 (COM1, COM2), IEEE-488.2
action modeAbsolute pressure, gauge pressure, compound gauge pressure, differential pressure
Pressure rangeVacuum ~ 280 MPa (40,000 psi)
Liquid usedQ-RPT less than A7M: Gas only
and everything else: Gas or oil
ProofreadingA2LA certified calibration report attached
Pressure connection pipingUp to A70M: 1/8 in NPT F
A70M and above: DH500 (equivalent to AE250C)
CE markAvailable (requires specification)
Measured pressure (Q-RPT)
Warm up timeコールド起動からは30分の温度安定時間を推奨
分解能最大1 ppm、ユーザー調節可能
1 年間の予測安定度1すべてのレンジおよびクラスで読み値の± 0.005
確度 2A10M(1,500 psi)までのQ-RPT
標準クラス:読み値の ± 0.008 %、読み値の ± 0.005 %、または Q-RPT スパンの 0.0024 % のいずれか大きい方4
プレミアム・クラス:読み値の ± 0.005 %、オートレンジ・スパンの読み値の ± 0.0015 %、または Q-RPT スパンの 0.0005 % のいずれか大きい方5
測定の不確かさ 3A10M(1,500 psi)までのQ-RPT
標準クラス:読み値の ± 0.010 % または Q-RPT スパンの 0.0030 % のいずれか大きい方4
プレミアム・クラス:読み値の ± 0.008 %、オートレンジ・スパンの 0.0024 %、または Q-RPT スパンの 0.0007 % のいずれか大きい方5
確度 2A14M~A140M(2,000~20,000 psi)のQ-RPT
読み値の± 0.012%またはQ-RPTスパンの0.0036%のいずれか大きい方4
測定の不確かさ 3A14M~A140M(2,000~20,000 psi)のQ-RPT
読み値の± 0.013%またはQ-RPTスパンの0.0039%のいずれか大きい方4
確度 2A200MN~A280M(30,000~40,000 psi)のQ-RPT
読み値の± 0.015%またはQ-RPTスパンの0.0045%のいずれか大きい方4
測定の不確かさ 3A200MN~A280M(30,000~40,000 psi)のQ-RPT
読み値の± 0.018%またはQ-RPTスパンの0.0054%のいずれか大きい方4
  1. AutoZero機能の定期使用を想定した場合の予測年間安定度リミット(k=2)。AutoZを使用しない絶対圧モードの予測年間安定度は±(Q-RPTスパンの0.005% + 読み値の0.005%)。A200MN~A280M(30,000~40,000 psi)のQRPT。
  2. 直線性、ヒステリシス、再現性を組み合わせた値。オンボード圧力計の分解能と短期安定度については、Axxx Q-RPTを使用したゲージ圧モードで± 1 Pa(0.00015 psi)を追加します。
  3. 精度、年間予測安定度、温度効果、校正の不確かさをISO「Guide to the Expression of Uncertainty in Measurement」に従って拡張(k=2)し組み合わせた場合の、印加圧力の真値からのQ-RPT指示値の最大偏差。
  4. Q-RPTスパンの100~30%では、読み値の%に測定圧力を掛けた値。Q-RPTスパンの30%では、読み値の%にQ-RPTスパンの30%を掛けた値。たとえば、QRPTが標準A160Kの場合、圧力測定の不確かさは、48 kPa(160 kPaスパンx 30%)までは0.010%に測定圧力を掛けた値、48 kPa未満では0.0048 kPa(160 kPaスパンx 30% x 0.01%)です。
  5. At 100-30% of the autorange span, the reading is% multiplied by the measured pressure. Below 30% of the autorange span, the reading% is multiplied by 30% of the autorange span. If the autorange span is less than 30% of the maximum Q-RPT span, then% of the reading is multiplied by the measured pressure, or% of the reading is multiplied by 9% of the Q-RPT span, whichever is greater. .. For example, if the Q-RPT is premium A160K and the autorange span is 160 kPa, the uncertainty of pressure measurement will be the measured pressure x 0.008% up to 48 kPa (160 kPa autorange span x 30%). Less than 48 kPa is 0.0038 kPa (160 kPa span x 30% x 0.008%). When the autorange span is 100 kPa (greater than 30% of the maximum Q-RPT span of 160 kPa), the uncertainty of pressure measurement is the measured pressure x up to 30 kPa (100 kPa autorange span x 30%). It is 0.008%, and less than 30 kPa is 0.0025 kPa (100 kPa span x 30% x 0.008%). When the autorange span is 30 kPa (less than 30% of the maximum Q-RPT span of 160 kPa), the uncertainty of pressure measurement is measured pressure x 0.008 up to 14.4 kPa (160 kPa autorange span x 9%). If it is less than 14.4 kPa, it will be 0.0012 kPa (160 kPa maximum Q-RPT span x 9% x 0.008%).

This point of contact in Japan for products Co., Ltd. a leading Giken has become. Click here for the Japanese data sheet .

モデル: RPM4基準圧力モニター

RPM4 mhhhac/mlllac

基準圧力モニター


ここで、
mhhhac は Hi Q-RPT の仕様です。
c は Q-RT のクラスです(s = 標準、p = プレミアム)

mlllac は Lo Q-RPT の仕様とクラスです。Lo Q-RPT がない場合は、空白のままにします。

使用可能な Q-RPT については、「特徴」の Q-RPT およびレンジの表を参照してください。

RPM4 04

-1 米国単位版 -2 SI 単位版


RPM4 05

CE マーク


RPM4 06

特別校正


RPM4 07

特殊試験液、Hi Q-RPT(液体を指定)


RPM4 08

特殊試験液、低 Q-RPT(液体を指定)


RPM4 09

-1 特殊構成、エアー・データ(A160K/A160K、A350K/A160Kのみ)


RPM4-LP
Low Pressure Monitor, -15 to 15 kPa (-60 to 60 inH2O)

3990-803

手動圧力制御パック、最大 3000 psi(207 bar)


RPM4-BAROM-1

基準圧力モニター


空気浮力補正および大気圧加算による絶対圧用、改良気圧測定

RPM4

基準圧力モニター、外部Q-RPT用または絶対モードAutoZ用(部品番号3072483)