TiX560 Infrared Camera with a Wide Angle Lens
Discontinued
Key features
- Distance to Spot 382:1
- 180 ° articulating lens for those tough shots
- Industry’s largest 5.7 inch LCD touchscreen for a 320x240 infrared camera
- Temperature measurements up to 1200 °C
- LaserSharp® Auto Focus – utilizing precision laser technology, focus on your target with pinpoint accuracy and get the correct image and temperature measurements
- Interchangeable smart lenses – no calibration required
- Capture images or radiometric video with remote control
This product is discontinued or reclassified
Fluke suggests:Fluke TiX580 Infrared Camera
Product overview: TiX560 Infrared Camera with a Wide Angle Lens
Designed for professional industrial inspections and building diagnostics, the TiX560 combined with the wide angle lens provides a wider field of vision allowing you to see more in tight spaces or view large areas in one glance.
Specifications: TiX560 Infrared Camera with a Wide Angle Lens
Key Features | |
IFOV with standard lens (spatial resolution) | 1.31 mRad |
Detector resolution | 320 x 240 (76,800 pixels) |
Field of view | 24 °H x 17 °V |
Minimum focus distance | 15 cm (approx. 6 in) |
IFOV with wide-angle lens | 2.62 mRad |
Field of view | 46 °H x 34 °V |
Minimum focus distance | 15 cm (approx. 6 in) |
SuperResolution | On camera and in software |
Image sharpening | Yes |
LaserSharp® Auto Focus | Yes, for consistently in-focus images. Every. Single. Time. |
Laser distance meter | Yes, calculates distance to the target for precisely focused images and displays distance on screen |
Advanced manual focus | Yes |
Streaming video (remote display) | Via USB or WiFi |
Touchscreen display (capacitive) | 14.4 cm (5.7 in) diagonal landscape color VGA (640 x 480) LCD with backlight |
Wireless connectivity | Yes, to PC, iPhone® and iPad® (iOS 4s and later), Android™ 4.3 and up, and WiFi to LAN (where available) |
Fluke Connect™ app compatible | Yes (where available) |
Fluke Connect™ tool compatible | Yes (where available). Connects wirelessly to select Fluke Connect™ enabled tools. Five simultaneous connections supported. |
IR-Fusion® technology | Yes |
AutoBlend™ mode | Yes |
Picture-In-Picture (PIP) | Yes |
Continuous AutoBlend™ | Set AutoBlend™ level across continuum |
Rugged, ergonomic design for one-handed use | Rotatable (articulating lens) 240 degrees |
Thermal sensitivity (NETD) | ≤ 0.045 °C at 30 °C target temp (45 mK) |
Filter mode (NETD improvement) | ≤ 0.03 °C at 30 °C target temp (30 mK) |
Level and span | Smooth auto and manual scaling |
Touchscreen adjustable level / span | Yes. Span and level can be easy and quickly set by simply touching the screen. |
Fast auto toggle between manual and auto modes | Yes |
Fast auto-rescale in manual mode | Yes |
Minimum span (in manual mode) | 2.0 °C (3.6 °F) |
Minimum span (in auto mode) | 3.0 °C (5.4 °F) |
Built-in digital camera (visible light) | 5 megapixel industrial performance |
Frame rate | 60 Hz or 9 Hz versions |
Laser pointer | Yes |
LED light (torch) | Yes |
Digital zoom | 2x, 4x, 8x |
Data Storage and Image Capture | |
Extensive memory options | Removable micro SD memory card, on-board flash memory, save-to-USB capability, direct download via USB-to-PC connection |
Post-capture image editing (on camera) | Yes. Conduct on camera analysis for in-field results. |
Advanced text annotation | Yes. Including standard shortcuts as well as user programmable options. |
File formats | Non-radiometric (.bmp) or (.jpeg) or fully radiometric (.is2); no analysis software required for non-radiometric (.bmp, .jpg and .avi) files |
Memory review | Thumbnail view navigation and review selection |
Software | SmartView® software, Fluke Connect™ (where available), and SmartView® Mobile App - full analysis and reporting software |
Export file formats with SmartView® software | BMP, DIB, GIF, JPE, JFIF, JPEG, JPG, PNG, TIF, and TIFF |
Voice annotation | 60 seconds maximum recording time per image; reviewable playback on camera; Bluetooth headset provided |
IR-PhotoNotes™ | Yes |
Text annotation | Yes |
Video recording | Standard and radiometric |
File formats video | Non-radiometric (MPEG - encoded .AVI) and fully radiometric (.IS3) |
Remote control and operation (for special and advanced applications) | Yes |
Auto capture (temperature and interval) | Yes |
Battery | |
Batteries (field-replaceable, rechargeable) | Two lithium ion smart battery packs with five-segment LED display to show charge level |
Battery life | Three hours continuous use per battery pack |
Battery charge time | 2.5 hours to full charge |
Battery charging system | Two-bay battery charger or in-imager charging. Optional 12 V automotive charging adapter |
AC operation | AC operation with included power supply (100 V AC to 240 V AC, 50/60 Hz) |
Power saving | User selectable sleep and power off modes |
Temperature Measurement | |
Temperature measurement range (not calibrated below -10 °C) | '-20 °C to +1200 °C (-4 °F to +2192 °F) |
Accuracy | ± 2 °C or 2 % (at 25 °C nominal, whichever is greater) |
On-screen emissivity correction | Yes (both value and table) |
On-screen reflected background temperature compensation | Yes |
On-screen transmission correction | Yes |
Color Palettes | |
Standard palettes | 8: Ironbow, Blue-Red, High Contrast, Amber, Amber Inverted, Hot Metal, Grayscale, Grayscale Inverted |
Ultra Contrast™ palettes | 8: Ironbow Ultra, Blue-Red Ultra, High Contrast Ultra, Amber Ultra, Amber Inverted Ultra, Hot Metal Ultra, Grayscale Ultra, Grayscale Inverted Ultra |
General Specifications | |
Color alarms (temperature alarms) | High-temperature and low-temperature |
Infrared spectral band | 7.5 μm to 14 μm (long wave) |
Operating temperature | -10 °C to +50 °C (14 °F to 122 °F) |
Storage temperature | -20 °C to +50 °C (-4 °F to 122 °F) without batteries |
Relative humidity | 10 % to 95 % non-condensing |
Center-point temperature measurement | Yes |
Spot temperature | Hot and cold spot markers |
User-definable spot markers | 3 user-definable spot markers |
Center box | Expandable-contractible measurement box with MIN-MAX-AVG temp |
Safety | IEC 61010-1: Overvoltage Category II, Pollution degree 2 |
Electromagnetic compatibility | IEC 61326-1: Basic EM Environment CISPR11, Group 1, Class A |
Australian RCM | IEC/61326-1 |
US FCC | CFR 47, Part 15 Subpart B |
Vibration | 0.03 g2/Hz (3.8 grms), 2.5g IEC 68-2-6 |
Shock | 25 g, IEC 68-2-29 |
Drop | Engineered to withstand 1 meter (3.4 feet) drop with standard lens |
Size (H x W x L) | 27.3 cm x 15.9 cm x 9.7 cm (10.8 in x 6.3 in x 3.8 in) |
Weight (battery included) | 1.5 kg (3.3 lb) |
Enclosure rating | IP54 (protected against dust, limited ingress; protection against water spray from all directions) |
Warranty | Two-years (standard), extended warranties are available |
Recommended calibration cycle | Two-years (assumes normal operation and normal aging) |
Supported languages | Czech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, and Turkish |
Models: TiX560 Infrared Camera with a Wide Angle Lens
FLK-TiX560-Wide2-60Hz-Kit
Fluke TiX560-Wide2-60Hz-Kit
Includes:
- TiX560 FC 60Hz thermal imager with standard infrared lens
- Wide Angle Infrared Smart Lens
- Ac power supply and battery pack charger (including universal ac adapters)
- Two, rugged lithium ion smart battery packs
- USB cable
- HDMI video cable
- Bluetooth headset (where available)
- Rugged, hard carrying case
- Adjustable neck and hand strap
- Flash drive with SmartView® Software and user manuals
- Warranty registration card and calibration certificate
FLK-TiX560-Wide2-9Hz-Kit
Fluke TiX560-Wide2-9Hz-Kit
Includes:
- TiX560 FC 9Hz thermal imager with standard infrared lens
- Wide Angle Infrared Smart Lens
- Ac power supply and battery pack charger (including universal ac adapters)
- Two, rugged lithium ion smart battery packs
- USB cable
- HDMI video cable
- Bluetooth headset (where available)
- Rugged, hard carrying case
- Adjustable neck and hand strap
- Flash drive with SmartView® Software and user manuals
- Warranty registration card and calibration certificate
Manuals + resources: TiX560 Infrared Camera with a Wide Angle Lens
- Saving measurements with AutoRecord™ measurements
- How to email a measurement using the Fluke Connect app
- What is Fluke Connect®
- Connecting multiple tools at the same time with Fluke Connect®
- Performing predictive maintenance with Fluke Connect™
- How to create an equipment baseline with EquipmentLog™ history
- Measuring from a safe distance using the Fluke Connect™ app
- Fluke Infrared Cameras: LaserSharp® Auto Focus
- Identifying intermittent conditions with TrendIt™ graphs
- Introduction to 789FC
- How to save measurements to EquipmentLog™ history
- Share equipment health with EquipmentLog™ history
- How to share measurements on equipment using the Fluke Connect™ app
- Using ShareLive™ video call to share live measurements and video
- How to record measurements and graphs
- Ti400 LaserSharp<sup>®</sup> Auto Focus
- Viewing and graphing three phase measurements
- Measurement history in one place using EquipmentLog™ history
- Understanding the Relevance of Emissivity to Temperature Measurement Calculation on Your Fluke Ti400 Ti300 Ti200
- What IR-Fusion® Technology with AutoBlend™ Mode can do for You