Fluke TiX560 Infrared Camera
Key features
- Advanced 320 x 240 infrared camera with large LCD touchscreen
- Provides large 5.7-inch responsive LCD touchscreen with 150% more viewing area than 3.5-inch screen
- Features a 240° rotating screen to navigate hard to reach objects
- Provides temperature measurements from -20 °C to +1200 °C (-4 °F to +2192 °F)
Product overview: Fluke TiX560 Infrared Camera
The Fluke TiX560 Infrared Camera offers troubleshooting agility in tight spaces
With the TiX560 camera you can easily maneuver over, under, and around objects with the 240° rotating screen and still view at a comfortable angle. This will help you capture critical infrared details without straining your neck. You can capture and process images faster and analyze images in the field on the 5.7 inch responsive touchscreen LCD with on-camera analytics. Save time by editing emissivity, background temp, transmissivity, palettes, color alarms, adjusting IR-Fusion, and enabling/disabling markers all on the camera.
Brings quality in focus
With the TiX560 you can instantly get an in-focus image of your target with precision accuracy with Fluke's exclusive LaserSharp® Auto Focus technology and built-in laser distance meter. This helps ensure that you get a quality image and accurate temperature measurements of the exact target you're inspecting. The TiX560 is compatible with interchangeable Fluke 2x and 4x telephoto, wide angle, and macro smart lenses that require no calibration.
Connect to increased productivity with Fluke Connect
You can to see, save and share images with multiple remote users from the field simultaneously, with ShareLive™ video call in Fluke Connect® and connect to the largest selection of wireless test and measurement tools. Combine measurements from multiple Fluke Connect-enabled tools into one IS2 image. And you can organize your measurements by asset in one location with EquipmentLog™ history and make better decisions faster.
Other useful features:
- Works with optional field-installable smart lenses for greater flexibility in additional applications
- Provides 4x the pixel data with on-camera SuperResolution to create a 640 x 480 resolution image
- Offers light and ergonomic handling with neck and hand strap for all day use
- Features LaserSharp® Auto Focus to produce consistently in-focus images for more accurate temperature measurements
- Includes a built-in laser distance meter that calculates the distance to your designated target up to 30 meters (100 feet)
- Enables quick and easy in-field analysis with IR-Fusion® blending technology and advanced touchscreen functions including continuous level and span adjustment and filter mode for improved thermal sensitivity
- Offers Fluke Connect® App compatibility to share results with remote users via a smart phone and connect to the largest network of wireless test and measurement tools (Fluke Connect not available in all countries)
- Captures images or radiometric video with remote control
- Includes Fluke Connect® SmartView® desktop software to optimize thermal images, perform analytics, quickly generate customizable reports, and export images to the format of your choice in the cloud*
*Fluke Connect® SmartView® analysis and reporting software is available in all countries but Fluke Connect system is not. Please check availability with your authorized Fluke representative.
Specifications: Fluke TiX560 Infrared Camera
Key Features | |
IFOV with standard lens (spatial resolution) | 1.31 mRad |
Detector resolution | 320 x 240 (76,800 pixels) |
Field of view | 24 °H x 17 °V |
Minimum focus distance | 15 cm (approx. 6 in) |
IFOV with optional telephoto lens | 0.65 mRad |
Field of view | 12 °H x 9 °V |
Minimum focus distance | 45 cm (approx. 18 in) |
IFOV with optional wide-angle lens | 2.62 mRad |
Field of view | 46 °H x 34 °V |
Minimum focus distance | 15 cm (approx. 6 in) |
SuperResolution* | On camera and in software |
Image sharpening | Yes |
LaserSharp® Auto Focus | Yes, for consistently in-focus images. Every. Single. Time. |
Laser distance meter | Yes, calculates distance to the target for precisely focused images and displays distance on screen |
Advanced manual focus | Yes |
Streaming video (remote display) | Via USB or WiFi |
Touchscreen display (capacitive) | 14.4 cm (5.7 in) diagonal landscape color VGA (640 x 480) LCD with backlight |
Wireless connectivity | Yes, to PC, iPhone® and iPad® (iOS 4s and later), Android™ 4.3 and up, and WiFi to LAN (where available) |
Fluke Connect™ app compatible | Yes (where available) |
Fluke Connect™ tool compatible | Yes (where available). Connects wireless to select Fluke Connect™ enabled tools. Five simultaneous connections supported. |
IR-Fusion® technology | Yes |
AutoBlend™ mode | Yes |
Picture-In-Picture (PIP) | Yes |
Continuous AutoBlend™ | Set AutoBlend™ level across continuum |
Rugged, ergonomic design for one-handed use | Rotatable (articulating lens) 240 degrees |
Thermal sensitivity (NETD) | ≤ 0.045 °C at 30 °C target temp (45 mK) |
Filter mode (NETD improvement) | ≤ 0.03 °C at 30 °C target temp (30 mK) |
Level and span | Smooth auto and manual scaling |
Touchscreen adjustable level / span | Yes. Span and level can be easy and quickly set by simply touching the screen. |
Fast auto toggle between manual and auto modes | Yes |
Fast auto-rescale in manual mode | Yes |
Minimum span (in manual mode) | 2.0 °C (3.6 °F) |
Minimum span (in auto mode) | 3.0 °C (5.4 °F) |
Built-in digital camera (visible light) | 5 megapixel industrial performance |
Frame rate | 60 Hz or 9 Hz versions |
Laser pointer | Yes |
LED light (torch) | Yes |
Digital zoom | 2x, 4x, 8x |
Data Storage and Image Capture | |
Extensive memory options | Removable micro SD memory card, on-board flash memory, save-to-USB capability, direct download via USB-to-PC connection |
Image capture, review, save mechanism | One-handed image capture, review, and save capability |
Post-capture image editing (on camera) | Yes. Conduct on camera analysis for in-field results. |
Advanced text annotation | Yes. Including standard shortcuts as well as user programmable options. |
File formats | Non-radiometric (.bmp) or (.jpeg) or fully radiometric (.is2); no analysis software required for non-radiometric (.bmp, .jpg and .avi) files |
Memory review | Thumbnail view navigation and review selection |
Software | SmartView® software, Fluke Connect™ (where available), and SmartView® Mobile App - full analysis and reporting software |
Export file formats with SmartView® software | BMP, DIB, GIF, JPE, JFIF, JPEG, JPG, PNG, TIF, and TIFF |
Voice annotation | 60 seconds maximum recording time per image; reviewable playback on camera |
IR-PhotoNotes™ | Yes |
Text annotation | Yes |
Video recording | Standard and radiometric |
File formats video | Non-radiometric (MPEG - encoded .AVI) and fully radiometric (.IS3) |
Remote control and operation (for special and advanced applications) | Yes |
Auto capture (temperature and interval) | Yes |
Battery | |
Batteries (field-replaceable, rechargeable) | Two lithium ion smart battery packs with five-segment LED display to show charge level |
Battery life | Three hours continuous use per battery pack |
Battery charge time | 2.5 hours to full charge |
Battery charging system | Two-bay battery charger or in-imager charging. Optional 12 V automotive charging adapter |
AC operation | AC operation with included power supply (100 V AC to 240 V AC, 50/60 Hz) |
Power saving | User selectable sleep and power off modes |
Temperature Measurement | |
Temperature measurement range (not calibrated below -10 °C) | '-20 °C to +1200 °C (-4 °F to +2192 °F) |
Accuracy | ± 2 °C or 2 % (at 25 °C nominal, whichever is greater) |
On-screen emissivity correction | Yes (both value and table) |
On-screen reflected background temperature compensation | Yes |
On-screen transmission correction | Yes |
Color Palettes | |
Standard palettes | 8: Ironbow, Blue-Red, High Contrast, Amber, Amber Inverted, Hot Metal, Grayscale, Grayscale Inverted |
Ultra Contrast™ palettes | 8: Ironbow Ultra, Blue-Red Ultra, High Contrast Ultra, Amber Ultra, Amber Inverted Ultra, Hot Metal Ultra, Grayscale Ultra, Grayscale Inverted Ultra |
General Specifications | |
Color alarms (temperature alarms) | High-temperature and low-temperature |
Infrared spectral band | 7.5 μm to 14 μm (long wave) |
Operating temperature | -10 °C to +50 °C (14 °F to 122 °F) |
Storage temperature | -20 °C to +50 °C (-4 °F to 122 °F) without batteries |
Relative humidity | 10 % to 95 % non-condensing |
Center-point temperature measurement | Yes |
Spot temperature | Hot and cold spot markers |
User-definable spot markers | 3 user-definable spot markers |
Center box | Expandable-contractible measurement box with MIN-MAX-AVG temp |
Safety | IEC 61010-1: Overvoltage Category II, Pollution degree 2 |
Electromagnetic compatibility | IEC 61326-1: Basic EM Environment CISPR11, Group 1, Class A |
Australian RCM | IEC/61326-1 |
US FCC | CFR 47, Part 15 Subpart B |
Vibration | 0.03 g2/Hz (3.8 grms), 2.5g IEC 68-2-6 |
Shock | 25 g, IEC 68-2-29 |
Drop | Engineered to withstand 1 meter (3.4 feet) drop with standard lens |
Size (H x W x L) | 27.3 cm x 15.9 cm x 9.7 cm (10.8 in x 6.3 in x 3.8 in) |
Weight (battery included) | 1.5 kg (3.3 lb) |
Enclosure rating | IP54 (protected against dust, limited ingress; protection against water spray from all directions) |
Warranty | Two-years (standard), extended warranties are available |
Recommended calibration cycle | Two-years (assumes normal operation and normal aging) |
Supported languages | Czech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, and Turkish |
* Coming soon via firmware upgrade |
Models: Fluke TiX560 Infrared Camera
Includes:
- Thermal imager with standard infrared lens
- Ac power supply and battery pack charger (including universal ac adapters)
- Two, rugged lithium ion smart battery packs
- USB cable
- HDMI video cable
- Bluetooth headset (where available)
- Rugged, hard carrying case
- Adjustable neck and hand strap
Includes:
- Thermal imager with standard infrared lens
- Ac power supply and battery pack charger (including universal ac adapters)
- Two, rugged lithium ion smart battery packs
- USB cable
- HDMI video cable
- Bluetooth headset (where available)
- Rugged, hard carrying case
- Adjustable neck and hand strap
Manuals + resources: Fluke TiX560 Infrared Camera
- TiX500, TiX501, TiX520, TiX560, TiX580 | Users manual
- TiX500, TiX501, TiX520, TiX560, TiX580 | Users manual supplement
- Radio Frequency Data Class A | Instruction sheet
- Thermal Imagers | Safety sheet
- TiX500, TiX501, TiX520, TiX560, TiX580 | Quick reference guide
- TiX500, TiX501, TiX520, TiX560, TiX580 | Statement of memory volatility
- TiX500, TiX520, TiX560, TiX580 | Safety sheet
- TiX500, TiX520, TiX560, TiX580 | Safety sheet supplement
- LaserSharp® Auto Focus
- How to email a measurement using the Fluke Connect app
- Connecting the T3000 FC with the Fluke Connect™ app
- Measuring from a safe distance using the Fluke Connect™ app
- Fluke Infrared Cameras: LaserSharp® Auto Focus
- Share equipment health with EquipmentLog™ history
- Ti400 LaserSharp<sup>®</sup> Auto Focus
- Viewing and graphing three phase measurements
- Measurement history in one place using EquipmentLog™ history
- Understanding the Relevance of Emissivity to Temperature Measurement Calculation on Your Fluke Ti400 Ti300 Ti200
- What IR-Fusion® Technology with AutoBlend™ Mode can do for You
- MultiSharp™ Focus