Fluke Ti480 PRO Infrared Camera
Key features
- Increased sensitivity to visualize temperature differences
- Easier to visualize and diagnose issues with sharper onscreen images, multiple rectangle markers and 9 color palettes
- More intuitive visual interface, improved, user-tested, touch screen interface
- More flexibility to visualize target, tiny-to-large with interchangeable smart lenses - no calibration required, 2x and 4x telephoto, wide angle and macro lens compatibility
Product overview: Fluke Ti480 PRO Infrared Camera
Increased sensitivity
Capturing and displaying temperature variances makes all the difference when diagnosing problems. The Fluke Ti480 PRO Infrared Camera has increased thermal sensitivity to capture minute differences and the latest Fluke technology for on-screen clarity to make it easy to visual issues in the field. With the enhanced measurement accuracy and the wider dynamic temperature range—up to 1000 °C with NETD as low as 50 mK—technicians can collect precise information for making informed decisions that boost the company’s return on investment.
Sharper onscreen images, multiple rectangle markers, and 9 color palettes
The Ti480 PRO features sharp on-screen images with clear visual color differentiation to speed troubleshooting. It displays deviations from standard temperatures using multiple Delta-T markers, allowing users to choose one as a reference point and the others to display a value as a difference. Multiple rectangle markers in-camera identify min/max temperatures for an area of the equipment or an equipment array. The camera distinguishes heat differences more easily with a new palette and a wider array of yellows and greens in the display.
Interchangeable smart lenses
The 640 x 480 resolution Ti480 PRO features improved, more intuitive touchscreen user interface to speed detection and diagnoses of issues. It is also compatible with all Fluke infrared smart lenses, which include macro, telephoto, and wide-angle options to capture virtually any target. And Fluke smart lenses are interchangeable between compatible cameras without calibration, making it easy to change and share lenses.
The PRO Series takes focus to a new level of clarity with MultiSharp™ Focus that rapidly takes multiple images and combines them to produce one in-focus image. The advanced focusing system enables users to capture an automated, focused image of multiple targets at once, delivering the image clarity needed by professional thermographers and maintenance managers to produce top-quality results and avoid costly rework.
Connected reporting
As part of the Fluke Connect® reliability platform, the wireless Ti480 PRO allows users to upload infrared images from anywhere and combine them with measurement data from multiple Fluke Connect test tools to create and share comprehensive reports from the job site via email and collaborate in real time with other colleagues, increasing productivity in the field.
What's in the box:
- Thermal camera with standard infrared lens
- AC power supply and battery pack charger (including universal AC adapters)
- Two, rugged lithium ion smart battery packs
- USB cable
- HDMI video cable
- 4 GB micro SD card
- Rugged, hard carrying case
- Adjustable hand strap
- Available by free download Fluke Connect® SmartView® desktop software and users manual
Specifications: Fluke Ti480 PRO Infrared Camera
Key features | |
IFOV with standard lens (spatial resolution) | 0.93 mRad, D:S 1065:1 |
Detector resolution | 640 x 480 |
SuperResolution | Captures and combines 4x the data to create a 1280 x 960 (614,400 pixels) image |
Infrared Resolution | 307,200 pixels |
MultiSharp™ Focus | Yes, focused near and far, throughout the field of view |
LaserSharp® Auto Focus | Yes, for consistently in-focus images |
Laser distance meter | Yes, calculates distance to the target for precisely focused images and displays distance on screen |
Advanced manual focus | Yes |
Ruggedized touchscreen display | 3.5 inch (landscape) 640 x 480 LCD |
Rugged, ergonomic design for one-handed use | Yes |
Digital zoom | 2x and 4x |
Temperature measurement | |
Temperature measurement range (not calibrated below -10 °C) | ≤-20 °C to 1000 °C (-4 °F to 1832 °F) |
Accuracy | ±2 °C or 2% (at 25 °C nominal, whichever is greater) |
Thermal sensitivity (NETD)* | ≤0.05 °C at 30 °C target temp (50 mK) |
On-screen emissivity correction | Yes (both value and table) |
On-screen reflected background temperature compensation | Yes |
On-screen transmission correction | Yes |
*Best possible |
Wireless connectivity | |
To PC, iPhone® and iPad® (iOS 4s and later), Android™ 4.3 and up, and WiFi to LAN (where available) | |
Fluke Connect® app compatible | Yes*, connect your camera to your smartphone, and images taken automatically upload to the Fluke Connect app for saving and sharing |
Fluke Connect® Assets optional software | Yes*, assign images to assets and create work orders. Easily compare measurement types in one location |
Fluke Connect® Instant Upload | Yes*, connect your camera to your building’s WiFi network, and images taken automatically upload to the Fluke Connect system for viewing on your smartphone or PC |
Fluke Connect® tool compatible | Yes*, connects wirelessly to select Fluke Connect enabled tools and displays measurements on camera screen |
IR-Fusion® technology | |
Adds the context of the visible details to your infrared image | |
AutoBlend™ mode | Min, Mid, Max IR plus full visible on camera; continously variable in software |
Picture-In-Picture (PIP) | Yes |
Built-in digital camera (visible light) | 5 MP |
Lenses | ||
Standard lens | IFOV (spatial resolution) | 0.93 mRad, D:S 1065:1 |
Field of view | 34 °H x 24 °V | |
Minimum focus distance | 15 cm (approx. 6 in) | |
IR-Fusion® technology | Picture-In-Picture and full screen | |
Optional 2x telephoto smart lens | IFOV (spatial resolution) | 0.46 mRad, D:S 1529:1 |
Field of view | 17 °H x 12 °V | |
Minimum focus distance | 45 cm (approx. 18 in) | |
IR-Fusion® technology | Picture-In-Picture and full screen | |
Optional 4x telephoto smart lens | IFOV (spatial resolution) | 0.23 mRad, D:S 2941:1 |
Field of view | 6 °H x 4.5 °V | |
Minimum focus distance | 1.5 cm (approx. 60 in) | |
IR-Fusion® technology | N/A | |
Optional wide-angle smart lens | IFOV | 1.85 mRad, D:S 377:1 |
Field of view | 48 °H x 34 °V | |
Minimum focus distance | 15 cm (approx. 6 in) | |
IR-Fusion® technology | Full screen |
Level and span | Smooth auto and manual scaling |
Fast auto toggle between manual and auto modes | Yes |
Fast auto-rescale in manual mode | Yes |
Minimum span (in manual mode) | 2.0 °C (3.6 °F) |
Minimum span (in auto mode) | 3.0 °C (5.4 °F) |
Data storage and image capture | |
Extensive memory options | Removable 4 GB micro SD memory card, 4 GB internal flash memory, save to USB flash drive capability, upload to Fluke Cloud™ for permanent storage |
Image capture, review, save mechanism | One-handed image capture,review, and save capability |
Image file formats | Non-radiometric (.bmp) or (.jpeg) or fully-radiometric (.is2); no analysis software required for non-radiometric (.bmp, .jpg and .avi) files |
Memory review | Thumbnail and fullscreen review |
Software | SmartView® software - full analysis and reporting software and Fluke Connect® system |
Export file formats with SmartView® software | Bitmap (.bmp), GIF, JPEG, PNG, TIFF |
Voice annotation | 60 seconds maximum recording time per image; reviewable playback on camera, optional bluetooth headset available but not required |
IR-PhotoNotes™ | Yes (5 images) |
Text annotation | Yes |
Video recording | Standard and radiometric |
File formats video | Non-radiometric (MPEG - encoded .AVI) and fully-radiometric (.IS3) |
Streaming video (remote display) | Yes, see the live stream of the camera display on your PC, smartphone, or TV monitor. Via USB, WiFi hotspot, or WiFi network to SmartView® software on a PC; via WiFi hotspot to the Fluke Connect® app on a smartphone; or via HDMI to a TV monitor |
Remote control operation | Yes, through SmartView® software or Fluke Connect® mobile app |
Auto capture (temperature and interval) | Yes |
Battery | |
Batteries (field-replaceable, rechargeable) | Two lithium ion smart battery packs with five-segment LED display to show charge level |
Battery life | 2-3 hours per battery (*Actual life varies depending on settings and usage) |
Battery charge time | 2.5 hours to full charge |
Battery charging system | Two-bay battery charger or in-imager charging. Optional 12 V automotive charging adapter |
AC operation | AC operation with included power supply (100 V AC to 240 V AC, 50/60 Hz) |
Power saving | User selectable sleep and power off modes |
Color palettes | |
Standard palettes | 9: Rainbow, Ironbow, Blue-Red, High Contrast, Amber, Amber Inverted, Hot Metal, Grayscale, Grayscale Inverted |
Ultra Contrast™ palettes | 9: Rainbow, Ironbow, Blue-Red, High Contrast, Amber, Amber Inverted, Hot Metal, Grayscale, Grayscale Inverted |
General specifications | |
Frame rate | 60 Hz or 9 Hz versions |
Laser pointer | Yes |
LED light (torch) | Yes |
Color alarms (temperature alarms) | High temperature, low temperature, and isotherms (within range) |
Center-point temperature measurement | Yes |
Spot temperature | Hot and cold spot markers |
User-definable spot markers | 3 user-definable spot markers |
Center box | Expandable-contractible measurement box with MIN-MAX-AVG temp display |
Infrared spectral band | 7.5 μm to 14 μm (long wave) |
Operating temperature | -10 °C to +50 °C (14 °F to 122 °F) |
Storage temperature | -20 °C to +50 °C (-4 °F to 122 °F) |
Relative humidity | 10% to 95% non-condensing |
Safety | IEC 61010-1: Overvoltage category II, Pollution Degree 2 |
Electromagnetic compatibility | IEC 61326-1: Basic EM environment. CISPR 11: Group 1, Class A |
Australian RCM | IEC 61326-1 |
US FCC | CFR 47, Part 15 Subpart B |
Vibration | 0.03 g2/Hz (3.8 g), 2.5 g IEC 60068-2-6 |
Shock | 25 g, IEC 60068-2-29 |
Drop | Engineered to withstand 2 meter (6.5 feet) drop with standard lens |
Size (H x W x L) | 27.7 x 12.2 x 16.7 cm (10.9 x 4.8 x 6.5 in) |
Weight (battery included) | 1.04 kg (2.3 lb) |
Enclosure rating | IEC 60529: IP54 (protected against dust, limited ingress; protection against water spray from all directions) |
Warranty | Two-years (standard), extended warranties are available |
Recommended calibration cycle | Two-years (assumes normal operation and normal aging) |
Supported languages | Czech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, and Turkish |
Models: Fluke Ti480 PRO Infrared Camera
Includes:
- Thermal imager with standard infrared lens
- AC power supply and battery pack charger (including universal AC adapters)
- Two, rugged lithium ion smart battery packs
- USB cable
- HDMI video cable
- 4 GB micro SD card
- Rugged, hard carrying case
- Adjustable hand strap
- Available by free download Fluke Connect® SmartView® desktop software and users manual
Includes:
- Thermal imager with standard infrared lens
- AC power supply and battery pack charger (including universal AC adapters)
- Two, rugged lithium ion smart battery packs
- USB cable
- HDMI video cable
- 4 GB micro SD card
- Rugged, hard carrying case
- Adjustable hand strap
- Available by free download Fluke Connect® SmartView® desktop software and users manual
Is it possible to scan the equipment through a glass barrier, knowing that the distance is estimated at 45 meters?
How long has camera been in service.
Manuals + resources: Fluke Ti480 PRO Infrared Camera
- Ti300 PRO, Ti300+, Ti400 PRO, Ti401 PRO, Ti450 PRO, Ti450SF6, Ti480 PRO | Users manual
- Thermal Imagers | Safety sheet
- Ti300 PRO, Ti300+, Ti400 PRO, Ti400+, Ti401 Pro, Ti450 PRO, Ti450 SF6, Ti480 PRO | Statement of memory volatility
- Ti300 PRO, Ti400 PRO, Ti450 PRO, Ti450 SF6, Ti480 PRO | Safety sheet
- Ti300 PRO,Ti300+, Ti400 PRO,Ti401 PRO, Ti450 PRO, Ti450 SF6, Ti480 PRO | Quick reference guide