Fluke TiX580 Infrared Camera
Compare products: thermal cameras
Key features
- Rugged, superbly engineered 640 x 480 thermal imaging camera
- Provides large 5.7-inch responsive LCD touchscreen with 150% more viewing area than 3.5-inch screen
- Features 240° rotating screen for unmatched shooting flexibility
- Provides 4x the pixel data with on-camera SuperResolution to create a 1280 x 960 resolution image
- Subject to Export Control
Product overview: Fluke TiX580 Infrared Camera
Unmatched shooting flexibility
Sometimes the infrared images you need to capture are the ones that are almost impossible to take. With a full 180-degree articulating lens and 5.7 inch touchscreen, the Fluke TiX580 Infrared Camera allows thermographers to easily navigate over, under, and around objects to preview and capture images with ease. The cameras are ideal for predictive maintenance, R&D, oil and gas, and utility applications where flexibility and higher resolution are essential.
On-board advanced analytics
The Fluke TiX580 Infrared Camera features Fluke IR-Fusion® technology with Picture-in-Picture, full visible light, and AutoBlend™ modes for easier identification and reporting of problems. On-board advanced analytics allow users to adjust or enhance images right on the camera without additional software. Also included is Fluke SmartView® software, which provides a suite of advanced tools to view, optimize, annotate, and analyze infrared images, and generate fully customizable professional reports.
Responsive LCD touchscreen
The TiX580 features a 5.7 inch responsive LCD touchscreen—the largest in its class with 150 percent more viewing area compared to a 3.5 inch screen. The large screen enables thermographers to quickly identify issues while still in the field as well as easily edit images directly on the camera, eliminating time in the office; time better spent solving the problem.
On-camera boosted resolution
SuperResolution mode boosts resolution four times so the normal 320 x 240 (76,800 pixel) resolution of the images captured increases to 640 x 480 (307,200 pixels) revealing even greater detail to better identify problems that might have been missed with lower resolution cameras. Optional telephoto and wide-angle lenses add versatility to meet a wide variety of applications.
Accurate temperature measurement
Out of focus images may produce inaccurate temperature measurements that can be off by as much as 20 degrees making it easy to miss potential problems. To ensure consistently in-focus images, the cameras feature LaserSharp® Auto Focus, exclusive to Fluke, which uses a built-in laser distance meter to pinpoint the target, and accurately calculate and display the distance.
Wireless connectivity and reporting
The Fluke TiX580 Infrared Camera is part of the Fluke Connect® system which allows technicians to wirelessly transmit measurement data from their test tools to their smart phones and tablets for secure storage on the cloud and universal team access from the field. Fluke Connect with ShareLive™ video call enables teams to easily share and access infrared inspections on the go and look at trends over time.
What's in the box:
- Thermal imager with standard infrared lens
- AC power supply and battery pack charger (including universal AC adapters)
- Two, rugged lithium ion smart battery packs
- USB cable
- HDMI video cable
- Bluetooth headset (where available)
- Rugged, hard carrying case
- Adjustable neck and hand strap
- Available by free download Fluke Connect® SmartView® desktop software and users manual
Specifications: Fluke TiX580 Infrared Camera
Key features | |
IFOV with standard lens (spatial resolution) | 0.93 mRad, D:S 1065:1 |
Detector resolution | 640 x 480 (307,200 pixels) |
SuperResolution | Yes, on camera and in software. Captures and combines 4x the data to create a 1280 x 960 image |
MultiSharp™ Focus | Yes, focused near and far, throughout the field of view |
LaserSharp® Auto Focus | Yes, for consistently in-focus images. Every. Single. Time. |
Laser distance meter | Yes, calculates distance to the target for precisely focused images and displays distance on screen |
Advanced manual focus | Yes |
Touchscreen display (capacitive) | 5.7 inch (14.4 cm) landscape 640 x 480 LCD |
Rugged, ergonomic design | 240 ° rotatable (articulating) lens |
Digital zoom | 2x, 4x, and 8x |
Pre-calibrated Lenses | wide angle, 2x telephoto, 4x telephoto and 25 micron/macro |
Temperature measurement | |
Temperature measurement range (not calibrated below -10 °C) | -20 °C to 1000 °C (-4 °F to 1832 °F) |
Accuracy | ±2 °C or 2% (at 25 °C nominal, whichever is greater) |
Thermal sensitivity (NETD)* | ≤ 0.05 °C at 30 °C target temp (50 mK) |
On-screen emissivity correction | Yes (both value and table) |
On-screen reflected background temperature compensation | Yes |
On-screen transmission correction | Yes |
Live line marker | Yes |
*Best possible |
Wireless connectivity | |
To PC, iPhone® and iPad® (iOS 4s and later), Android™ 4.3 and up, and WiFi to LAN (where available) | |
Fluke Connect® app compatible | Yes, connect your camera to your smartphone, and images taken automatically upload to the Fluke Connect app for saving and sharing |
Fluke Connect Assets optional software | Yes, assign images to assets and create work orders. Easily compare measurement types - whether mechanical, electrical or infrared images - in one location. |
Fluke Connect Instant Upload | Yes, connect your camera to your building's WiFi network, and images taken automatically upload to the Fluke Connect system for viewing on your smartphone or PC |
Fluke Connect tool compatible | Yes, connects wirelessly to select Fluke Connect enabled tools and displays measurements on camera screen. Five simultaneous connections supported. |
Fluke Connect SmartView desktop software | Yes |
IR-Fusion® technology | |
Adds the context of the visible details to your infrared image | |
AutoBlend™ mode | Continuously variable |
Picture-In-Picture (PIP) | 100%, 75%, 50%, 25% IR |
Built-in digital camera (visible light) | 5 MP |
Lenses | ||
Standard lens | IFOV (spatial resolution) | 0.93 mRad, D:S 1065:1 |
Field of view | 34 °H x 24 °V | |
Minimum focus distance | 15 cm (approx. 6 in) | |
IR-Fusion® technology | Picture-in-picture and full screen | |
Optional 2x telephoto smart lens | IFOV | 0.33 mRad. D:S is 2145.1 |
Field of view | 12 °H x 8.5 °V | |
Minimum focus distance | 45 cm (approx. 18 in) | |
IR-Fusion® technology | Picture-in-picture and full screen | |
Optional wide-angle smart lens | IFOV | 1.85 mRad, D:S is 525:1 |
Field of view | 48 °H x 34 °V | |
Minimum focus distance | 15 cm (approx. 6 in) | |
IR-Fusion® technology | Full screen |
Level and span | |
Smooth auto and manual scaling | |
Touchscreen adjustable level/span | Yes. Span and level can be easily and quickly set by simply touching the screen |
Fast auto toggle between manual and auto modes | Yes |
Fast auto-rescale in manual mode | Yes |
Minimum span (in manual mode) | 2.0 °C (3.6 °F) |
Minimum span (in auto mode) | 3.0 °C (5.4 °F) |
Data storage and image capture | |
Extensive memory options | Removable 4 GB micro SD memory card, 4 GB internal flash memory, save to USB flash drive capability, upload to Fluke Cloud for permanent storage. |
Image file formats | Non-radiometric (.bmp, .jpeg), or fully radiometric (.is2); no analysis software required for non-radiometric (.bmp, .jpg) files |
Memory review | Thumbnail and fullscreen review |
Software | Fluke Connect SmartView software - full analysis and reporting software and Fluke Connect system |
Export file formats with Fluke Connect software | Bitmap (.bmp), GIF, JPEG, PNG, TIFF |
Voice annotation | 60 seconds maximum recording time per image; reviewable playback on camera |
IR-PhotoNotes™ | Yes (5 images) |
Advanced text annotation | Yes. Including standard shortcuts as well as user programmable options |
Video recording | Standard and radiometric |
File formats video | Non-radiometric (MPEG - encoded .AVI) and fully-radiometric (.IS3) |
Remote display viewing | Yes, see the live stream of the camera display on your PC, smartphone, or TV monitor. Via USB, WiFi hotspot, or WiFi network to Fluke Connect SmartView software on a PC; via WiFi hotspot to the Fluke Connect app on a smartphone; or via HDMI to a TV monitor |
Remote control operation | Yes, through Fluke Connect SmartView desktop software or Fluke Connect mobile app |
Auto capture (temperature and interval) | Yes |
MATLAB® and LabVIEW® tool boxes | Integrate camera data, infrared video and images into these software platforms to support R&D analysis |
Battery | |
Batteries (field-replaceable, rechargeable) | Two lithium ion smart battery packs with five-segment LED display to show charge level |
Battery life | 2-3 hours per battery (Actual life varies depending on settings and usage) |
Battery charge time | 2.5 hours to full charge |
Battery charging system | Two-bay battery charger or in-imager charging. Optional 12 V automotive charging adapter |
AC operation | AC operation with included power supply (100 V AC to 240 V AC, 50/60 Hz) |
Power saving | User selectable sleep and power off modes |
Color palettes | |
Standard palettes | 8: Ironbow, Blue-Red, High Contrast, Amber, Amber Inverted, Hot Metal, Grayscale, Grayscale Inverted |
Ultra Contrast™ palettes | 8: Ironbow Ultra, Blue-Red Ultra, High Contrast Ultra, Amber Ultra, Amber Inverted Ultra, Hot Metal Ultra, Grayscale Ultra, Grayscale Inverted Ultra |
General specifications | |
Frame rate | 60 Hz or 9 Hz versions |
Laser pointer | Yes |
LED light (torch) | Yes |
Color alarms (temperature alarms) | High temperature, low temperature, and isotherms (within range) |
Center-point temperature measurement | Yes |
Spot temperature | Hot and cold spot markers |
User-definable spot markers | 3 user-definable spot markers |
Center box | Expandable-contractible measurement box with MIN-MAX-AVG temp display |
Infrared spectral band | 7.5 μm to 14 μm (long wave) |
Operating temperature | -10 °C to +50 °C (14 °F to 122 °F) |
Storage temperature | -20 °C to +50 °C (-4 °F to 122 °F) |
Relative humidity | 10% to 95% non-condensing |
Safety | IEC 61010-1: Overvoltage category II, Pollution Degree 2 |
Electromagnetic compatibility | IEC 61326-1: Basic EM environment. CISPR 11: Group 1, Class A |
Australian RCM | IEC 61326-1 |
US FCC | CFR 47, Part 15 Subpart B |
Vibration | 0.03 g2/Hz (3.8 g), 2.5 g IEC 60068-2-6 |
Shock | 25 g, IEC 60068-2-29 |
Drop | 25 g, IEC 68-2-29/Engineered to withstand 1 meter (3.3 feet) drop with standard lens |
Size (H x W x L) | 27.3 x 15.9 x 9.7 cm (10.8 x 6.3 x 3.8 in) |
Weight (battery included) | 1.54 kg (3.4 lb) |
Enclosure rating | IEC 60529: IP54 (protected against dust, limited ingress; protection against water spray from all directions) |
Warranty | Two-years (standard), extended warranties are available |
Recommended calibration cycle | Two-years (assumes normal operation and normal aging) |
Supported languages | Czech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, and Turkish |
Models: Fluke TiX580 Infrared Camera
Includes:
- Thermal imager with standard infrared lens
- AC power supply and battery pack charger (including universal AC adapters)
- Two, rugged lithium ion smart battery packs
- USB cable
- HDMI video cable
- Bluetooth headset (where available)
- Rugged, hard carrying case
- Adjustable neck and hand strap
- Available by free download Fluke Connect® SmartView® desktop software and users manual
Includes:
- Thermal imager with standard infrared lens
- AC power supply and battery pack charger (including universal AC adapters)
- Two, rugged lithium ion smart battery packs
- USB cable
- HDMI video cable
- Bluetooth headset (where available)
- Rugged, hard carrying case
- Adjustable neck and hand strap
- Available by free download Fluke Connect® SmartView® desktop software and users manual
Is this camera used for methane leak detection and quantification of measurement taken?
While capturing the radiometric videos, the recording stopped by itself unpredictably like sometimes, it recorded continuously for more than 40 mins, at other time it stopped at 20 mins only. Please help to figure out the reason.
Hi, Uregent Please is it possible to use headset Bluetooth with camera TIX580 9 HZ in Algeria? Please how to activate it. Thank you Best regards. 00213 5 53 62 25 73
Manuals + resources: Fluke TiX580 Infrared Camera
- TiX500, TiX501, TiX520, TiX560, TiX580 | Users manual
- TiX500, TiX501, TiX520, TiX560, TiX580 | Users manual supplement
- Thermal Imagers | Safety sheet
- TiX500, TiX501, TiX520, TiX560, TiX580 | Quick reference guide
- TiX500, TiX501, TiX520, TiX560, TiX580 | Statement of memory volatility
- TiX500, TiX520, TiX560, TiX580 | Safety sheet
- TiX500, TiX520, TiX560, TiX580 | Safety sheet supplement