Kit Combo HVAC per il termometro ad infrarossi con schermo VT04
Non più disponibile
Caratteristiche principali
VT04 Visual IR Thermometer features:
- Unlimited applications – See data sheet for powerful applications and details
- Built-in digital camera – Every Fluke Visual IR Thermometer has a built-in digital camera
- Exclusive thermal heat map blending overlay – With one button, blend digital images and thermal heat maps to instantly show the exact location of the issue
- No training required - Fully automatic with built-in intelligence
- True pocket size design – Less than half the size of an average infrared camera
- SmartView® reporting software – Store up to 10,000 images per Gb on included SD card and make professional reports on included professional software
- Automatic hot and cold spot trackers
- Breakthrough affordability – Fraction of the cost of infrared cameras that require costly training and software
- Powerful resolution with PyroBlend® Plus optics:
- Best-in-class field of view: 28 ° x 28 ° (40% wider for tight spaces)
- 4 times sharper images
- Alarm and time lapse features:
- Hi/Lo temperature alarm– Find hot spots in seconds with the alarm feature
- Time lapse image capture– Automatically monitor equipment over time
- Automated monitoring alarm – Automatically capture images after an alarm has been triggered
902 HVAC Clamp Meter features:
- Designed for HVAC applications with capacitance, DC Current (µA), and temperature measurements
- Small body and jaws fit perfectly in your hand and into tight places
- Handy 'Display Hold' button keeps measurements on the display
- Meter controls are positioned so current measurements can be done with one hand (index finger on clamp opening lever and thumb on rotary switch)
- Large, backlit display is easy-to-see in less than ideal conditions
- Auto shut-off maximizes battery life so the meter works when you need it
- Three year warranty
116 Digital Multimeter features:
- Built-in thermometer for HVAC applications
- Microamps to test flame sensors
- Low input impedance: helps prevent false readings due to ghost voltage
- Large white LED backlight to work in poorly lit areas
- Resistance, continuity, frequency and capacitance
- Min/Max/Average with elapsed time to record signal fluctuations
- Compact ergonomic design for one-handed operation
- Compatible with optional magnetic hanger (ToolPak™)
- CAT III 600 V safety rated
Questo prodotto non è più disponibile o è stato riclassificato
Fluke suggerisce:Termometro ad infrarossi con schermo Fluke VT04
Descrizione generale del prodotto: Kit Combo HVAC per il termometro ad infrarossi con schermo VT04
Risparmiate denaro e acquistate il VT04, il multimetro a pinza Fluke 902 e il multimetro digitale Fluke 116. Insieme, questi strumenti offrono ai tecnici HVAC tutto il necessario per la ricerca guasti e la diagnostica dei problemi difficili da individuare.
Dati tecnici: Kit Combo HVAC per il termometro ad infrarossi con schermo VT04
Termometro ad infrarossi con schermo Fluke VT04
Caratteristiche principali | |
Fotocamera digitale integrata | Sì |
Sovrapposizione di mappe termiche | Sì, 5 modalità di sovrapposizione |
Sistema di risoluzione delle immagini | Ottica PyroBlend™ Plus: immagini *4 volte più nitide rispetto al modello VT02 |
Campo visivo (FOV) | 28 ° x 28 ° |
Allarmi per temperature alte/basse | Sì |
Cattura di immagini time lapse | Sì |
Allarme Auto-monitor | Sì |
Tipo di batterie | Ricaricabili agli ioni di litio |
Formazione | Nessuna formazione richiesta |
Ergonomia | Design sottile e compatto |
Marcatori di punti caldi e freddi | Sì |
Caratteristiche generali | |
Durata della batteria | Otto (8) ore |
Gamma di misura della temperatura | Da -10 °C a +250 °C (da 14 °F a 482 °F) |
Precisione di misura della temperatura | ± 2 °C oppure ± 2 % |
Misura di temperatura | Sì, punto centrale |
Dispositivo di memorizzazione (scheda micro SD) | Consente di memorizzare fino a 10.000 immagini per GB (scheda da quattro (4) GB inclusa) |
Banda dello spettro a infrarossi | Da 6,5 μm a 14 μm |
Livello e intervallo | Auto |
Meccanismo di messa a fuoco | Automatico, nessuna formazione necessaria grazie al software interno |
Opzioni di messa a fuoco: esclusive opzioni VICINO/LONTANO selezionabili dall'utente | VICINO < 23 cm; LONTANO > 23 cm |
Dimensioni | 21 x 7,5 x 5,5 cm < 300 g |
Formato file | Sulla scheda SD viene salvato il formato .is2. L'utente può creare report professionali o esportare immagini in SmartView® (BMP, DIB, GIF, SPE, FIF, SPEG, JPG, PNG, TIF e TIFF) |
Sicurezza e conformità | CFR47: 2009 Classe A. Parte 15 sottoparte B; CE: EN 61326:2006; IEC/EN 61010-1:2010 |
Garanzia | Due (2) anni |
Multimetro a pinza a vero valore RMS HVAC Fluke 902
Specifiche | ||
Tensione DC | Gamma | 0 – 600,0 V |
Precisione | 1% ± 5 punti | |
Tensione AC (a vero valore RMS) | Gamma | 0 – 600,0 V |
Precisione | 1% ± 5 punti (50/60 Hz) | |
Corrente AC (a vero valore RMS) | Gamma | 0 – 600,0 A |
Precisione | 2,0% ± 5 punti (50/60 Hz) | |
Corrente DC | Gamma | 0 - 200,0 µA |
Precisione | 1% ± 5 punti | |
Resistenza | Gamma | 0 – 9999 Ω |
Precisione | 1,5% ± 5 punti | |
Continuità | ≤ 30 Ω | |
Temperatura¹ | Gamma | Da -10 °C a 400 °C (da -14 °F a 752 °F) |
Precisione | ± 1,0% + 0,8 °C (± 1,0% + 1,5 °F) tipica | |
Gamma | Da -40 °C a -10 °C (da -40 °F a -14 °F) | |
Precisione | ± 5,0% + 1,5 °C (± 5,0% + 3,3 °F) tipica | |
Capacità | Gamma | 1-1000 µF |
Precisione | 1,9% ±2 punti | |
1. L'errore non include gli errori delle termocoppie tipo K | ||
Specifiche generali e meccaniche | ||
Peso | 0,7 kg | |
Dimensioni | 10,75 x 4,25 x 2,44 in | |
Tipo di batterie | (2) batterie alcaline AA |
Multimetro digitale Fluke 116
Specifiche tecniche | ||
Tensione massima tra qualsiasi terminale e la massa | 600 V | |
Protezione da sovratensioni | Picco da 6 kV per IEC 61010-1 600 VCAT III, grado di inquinamento 2 | |
Display | Digitale: 6.000 punti, aggiornamenti: 4 al secondo | |
Istogramma | 33 segmenti, aggiornamento ogni 32 secondi | |
Temperatura operativa | Da -10 °C a +50 °C | |
Temperatura di stoccaggio | Da -40 °C a 60 °C | |
Tipo di batterie | Batteria alcalina da 9 volt, NEDA 1604A/ IEC 6LR61 | |
Durata della batteria | 400 ore tipica, senza retroilluminazione | |
Specifiche di precisione | ||
DC in millivolt | Gamma/risoluzione | 600,0 mV / 0,1 mV |
Precisione | ± ([% della misura] + [punti]): 0,5% + 2 | |
Volt CC | Gamma/risoluzione | 6,000 V / 0,001 V 60,00 V / 0,01 V 600,00 V / 0,1 V |
Precisione | ± ([% della misura] + [punti]): 0,5% + 2 | |
Auto-V | Gamma/risoluzione | 600,0 V / 0,1 V |
Precisione | 2,0% + 3 (DC, da 45 Hz a 500 Hz) 4,0% + 3 (da 500 Hz a 1 kHz) | |
Vero valore RMS millivolt¹ AC | Gamma/risoluzione | 600,0 mV / 0,1 mV |
Precisione | 1,0% + 3 (DC, da 45 Hz a 500 Hz) 2,0% + 3 (da 500 Hz a 1 kHz) | |
Vero valore RMS volt¹ AC | Gamma/risoluzione | 6,000 V / 0,001 V 60,00 V / 0,01 V 600,0 V / 0,1 V |
Precisione | 1,0% + 3 (DC, da 45 Hz a 500 Hz) 2,0% + 3 (da 500 Hz a 1 kHz) | |
Continuità | Gamma/risoluzione | 600 Ω / 1 Ω |
Precisione | Segnale acustico attivato a < 20 Ω, disattivato a > 250 Ω; rileva circuiti aperti o cortocircuiti a partire da 500 μs. | |
Ohm | Gamma/risoluzione | 600,0 Ω / 0,1 Ω 6,000 kΩ / 0,001 kΩ 60,00 kΩ / 0,01 kΩ 600,0 kΩ / 0,1 kΩ 6,000 MΩ / 0,001 MΩ |
Precisione | 0,9% + 1 | |
Gamma/risoluzione | 40,00 MΩ / 0,01 MΩ | |
Precisione | 5% + 2 | |
Test diodi | Gamma/risoluzione | 2,00 V / 0,001 V |
Precisione | 0,9% + 2 | |
Capacità | Gamma/risoluzione | 1000 nF / 1 nF 10,00 μF / 0,01 μF 100,0 μF / 0,1 μF 9999 μF / 1 μF 100 μF to 1000 μF |
Precisione | 1,9% + 2 | |
Gamma/risoluzione | > 1000 μF | |
Precisione | 5% + 20% | |
Capacità Lo-Z | Gamma | Da 1 nF a 500 μF |
Precisione | 10% + 2 tipica | |
Temperatura² | Gamma/risoluzione | Da -40 °C a 400 °C / 0,1 °C |
Precisione | 1% + 10² | |
Gamma/risoluzione | Da -40 °F a 752 °F / 0,2 °F | |
Precisione | 1% + 18² | |
μamp AC a vero valore RMS (da 45 Hz a 500 Hz) | Gamma/risoluzione | 600,0 μA / 0,1 μA |
Precisione | 1,0% + 2 | |
μamps DC | Gamma/risoluzione | 600,0 μA / 0,1 μA |
Precisione | 1,0% + 2 | |
Hz (ingresso V o A) | Gamma/risoluzione | 99,99 Hz / 0,01 Hz 999,99 Hz / 0,1 Hz 9,999 Hz / 0,001 Hz 50,00 Hz / 0,01 Hz |
Precisione | 0,1% + 2 | |
1. Tutte le gamme di tensione AC eccetto Auto-V/LoZ sono specificate dall'1% al 100% della gamma. Auto-V LoZ è specificata da 0,0 V. 2. L'incertezza (precisione) della temperatura non include l’errore della sonda della termocoppia. 3. La frequenza è accoppiata AC, da 5 Hz a 50 kHz per la tensione AC. La frequenza è accoppiata DC, da 45 Hz a 5 kHz per la corrente AC. 4. Gamma di temperatura/Risoluzione: da -40 °F a 752 °F / 0.2 °F. | ||
Specifiche generali e meccaniche | ||
Dimensioni | 167 x 84 x 46 mm | |
Peso | 550 g | |
Garanzia | 3 anni |
Modelli: Kit Combo HVAC per il termometro ad infrarossi con schermo VT04
Fluke VT04-HVAC-Kit
Fluke VT04 Visual IR Thermometer HVAC Combo Kit
Include:
- Termometro ad infrarossi con schermo VT04
- Multimetro a pinza 902 a vero valore RMS HVAC
- Multimetro digitale 116, progettato specificamente per i professionisti del settore HVAC