Fluke BK120 SmartTrace™ Breaker Finder and 107 Pocket Digital Multimeter

Model#:Fluke BK120/107 KitPart#:5587530
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 85.6ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • Fluke BK120 SmartTrace™ Breaker Finder and 107 Pocket Digital Multimeter
  • Fluke BK120 circuit breaker finder and transmitter
  • Front of Fluke 107 Multimeter
  • Video Player is loading.
    Current Time 0:00
    Duration 1:18
    Loaded: 0%
    Stream Type LIVE
    Remaining Time 1:18
     
    1x
      • Chapters
      • descriptions off, selected
      • en (Main), selected
    1. Fluke BK120 SmartTrace™ Breaker Finder and 107 Pocket Digital Multimeter
    2. Fluke BK120 circuit breaker finder and transmitter
    3. Front of Fluke 107 Multimeter
    4. Fluke BK120 Breaker Finder with NCV Mode

    Key features

    Read more
    Out of stock
    $227.99
    FREE Shipping
    30-day Returns

    Product overview: Fluke BK120 SmartTrace™ Breaker Finder and 107 Pocket Digital Multimeter

    Presenting the perfect pair of tools for both seasoned electrical professionals and DIY enthusiasts - The BK120 with 107 DMM

    The Fluke BK120 with NCV mode

    This versatile device simplifies electrical tasks, circuit tracing, and troubleshooting for electricians, homeowners, and maintenance professionals. The BK120 features a Breaker Finder and Transmitter, ensuring accurate circuit breaker identification, eliminating uncertainty, and ultimately saving valuable time. It's suitable for use in CAT III 150 V environments and boasts a comfortable and ergonomic design.

    Key Features:

    • Dual Sensitivity: Detects AC voltage in low and high voltage situations, enhancing safety
    • Built-in GFCI Tester
    • Bright flashlight
    • Low battery indicator
    • Auto sleep mode

    Fluke 107 Pocket Digital Multimeter

    The Fluke 107 is a compact, rugged digital multimeter that fits in your pocket. It's ideal for quick troubleshooting, offering reliable measurements for AC/DC voltage, current, resistance, capacitance, diode, frequency, and duty-cycle. With a CAT III 600V safety rating, it ensures your safety on the job.

    Key Features:

    • AC and DC voltage
    • AC and DC current
    • Resistance
    • Capacitance
    • Diode
    • Frequency and duty-cycle

    Specifications: Fluke BK120 SmartTrace™ Breaker Finder and 107 Pocket Digital Multimeter

    Fluke BK120 SmartTrace™ Breaker Finder

     BK120 TransmitterBK120 Receiver
    Safety ratingCAT III 150 VCAT III 150 V
    Rated operating voltage110 V AC to 125 V AC at 6 mA
    Rated frequency50/60 Hz
    GFCI test
    Wiring check
    Wiring indication1 red, 2 green
    Breaker finder indicationVisual and audio
    NCV detection90 V AC to 240 V AC, 50/60 Hz
    Dual sensitivity
    Visual and audio indications
    Flashlight
    Auto power off
    Low battery indication
    Power supplyLine powered2 AAA

    Fluke 107 Pocket Digital Multimeter

    Accuracy is available for one year after calibration, operating from 18 °C to 28 °C and relative humidity from 0% to 75%. The format of the accuracy specification is: ± ([% of reading] + [least significant digit])

    Precision specifications
    AC voltage
    (40 Hz to 500 Hz)1
    RangeResolutionAccuracy
    6.000 V
    60.00 V
    600.0 V
    0.001 V
    0.01 V
    0.1 V
    1.0 % + 3
    DC voltage6.000 V
    60.00 V
    600.0 V
    0.001 V
    0.01 V
    0.1 V
    0.5 % + 3
    Exchange millivolts600.0 mV0.1 mV3.0 % + 3
    Diode test22.000 V0.001 V10 %
    Resistance
    (ohm)
    400.0 Ω
    4.000 kΩ
    40.00 kΩ
    400.0 kΩ
    4.000 MΩ
    40.00 MΩ
    0.1 Ω
    0.001 kΩ
    0.01 kΩ
    0.1 kΩ
    0.001 MΩ
    0.01 MΩ
    0.5 % + 3
    0.5 % + 2
    0.5 % + 2
    0.5 % + 2
    0.5 % + 2
    1.5% + 3
    Capacitor350.00 nF
    500.0 nF
    5.000 μF
    50.00 μF
    500.0 μF
    1000 μF
    0.01 nF
    0.1 nF
    0.001 μF
    0.01 μF
    0.1 μF
    1 μF
    2 % + 5
    2 % + 5
    5 % + 5
    5 % + 5
    5 % + 5
    5 % + 5
    Frequency4 Hz
    (10 Hz – 100 kHz)
    50.00 Hz
    500.0 Hz
    5.000 kHz
    50.00 kHz
    100.0 kHz
    0.01 Hz
    0.1 Hz
    0.001 kHz
    0.01 kHz
    0.1 kHz
    0.1 % + 3
    Duty cycle41 % to 99 %0.10 %1 % typical case5
    AC current
    (40 Hz - 200 Hz)
    4.000 A
    10.00 A
    0.001 A
    0.01 A
    1.5 % + 3
    DC4.000 A
    10.00 A
    0.001 A
    0.01 A
    1.5 % + 3
    1. All AC current, frequency, and duty cycle are specified from 1% to 100% of the range. Input values below 1% of range are not specified.
    2. Typically, the open circuit test voltage is 2.0 V and the short circuit current is < 0.6 mA.
    3. The parameters do not include errors due to test lead capacitance and capacitor substrate (up to 1.5 nF in the 50 nF range).
    4. All AC current, frequency, and duty cycle are specified from 1% to 100% of the range. Input values below 1% of range are not specified.
    5. Typically, the frequency is 50 Hz or 60 Hz and the duty cycle is 10% to 90%.
    FeaturesOverload protectionInput impedance (nominal value)Common mode rejection ratioNormal mode rejection ratio
    AC voltage600 V 1>10 MΩ <100 pF 2>60 dB at 50 Hz or 60 Hz at DC current
    Exchange millivolts600 mV>1M, <100 pF>80 dB at 50 Hz or 60 Hz
    DC voltage600 V 1>10 MΩ <100 pF>100 dB at 50 Hz or 60 Hz at DC current>60 dB at 50 Hz or 60 Hz
    1. Up to 6 x 105 V Hz
    2. For medium voltage (alternating current), the input impedance is approximately 1 MΩ.
    General technical indicators
    The highest voltage applied to any terminal and ground600 V
    Display (LCD)6000 counts, updated three times per second
    Type of batteryTwo AAA batteries (NEDA 24A, IEC LR03)
    Battery lifeAt least 200 hours
    Temperature
    Operating temperature0 °C to 40 °C
    Storage temperature-30 °C to 60 °C
    Relative humidity
    Working humidityNo condensation below 10 °C
    ≤ 90 % at 10 °C to 30 °C; ≤ 75 % at 30 °C to 40 °C
    Working humidity, 40 MΩ range≤ 80 % at 10 °C to 30 °C; ≤ 70 % at 30 °C to 40 °C
    Altitude
    Working elevation2000 m
    Storage altitude12,000 m
    Temperature coefficient0.1 X (specified accuracy) / °C (<18 °C or >28 °C)
    Current input fuse protection11A, 1000V fast-melting type, must use Fluke designated parts
    Volume (height x width x length)142 mm x 69 mm x 28 mm
    Weight200 g
    Protection levelIEC 60529: IP 40
    SafetyIEC 61010-1: 600 V CAT III, pollution degree 2
    Electromagnetic environmentIEC 61326-1: Portable
    Electromagnetic compatibilityApplicable only in Korea. Class A equipment (industrial broadcasting and communication equipment)1
    1 This product meets the requirements of industrial (Class A) electromagnetic wave equipment, which should be noted by the seller or user. The device is suitable for use in a work environment, not a home environment.

    Models: Fluke BK120 SmartTrace™ Breaker Finder and 107 Pocket Digital Multimeter

    Fluke BK120/107 Kit

    Fluke BK120 SmartTrace™ Breaker Finder and 107 Pocket Digital Multimeter

    Part#: 5587530

    Includes:

    • BK120
      • Breaker Finder Receiver
      • Transmitter
      • Batteries
      • Quick Reference guide
    • 107 Pocket Digital Multimeter
      • Fluke 107 palm-sized digital multimeter
      • (1 pair) TL75 Hard Point™ Test Leads
      • (2) AAA batteries (installed)
      • SmartStrap™ intelligent magnetic, multi-purpose lanyard
      • 1-year warranty
    • bvseo_sdk, p_sdk, 3.2.1
    • CLOUD, getContent, 60.56ms
    • QUESTIONS, PRODUCT
    • bvseo-msg: HTTP status code of 404 was returned;
    • bvseo_sdk, p_sdk, 3.2.1
    • CLOUD, getReviews, 22.14ms
    • REVIEWS, PRODUCT
    • bvseo-msg: HTTP status code of 404 was returned;
    Please enable cookies to view product reviews.