Detector resolution | 640 x 480 (307,200 pixels) | 120 x 90 (10,800 pixels) | |
Display | 5.7 inch touchscreen LCD, 640 x 480 pixel resolution | 3.5 inch (8.9 cm landscape) 320 x 240 touchscreen LCD | |
Field of view (FOV) | 34 °H × 24 °V | 50 °H x 38 °V | |
Focus system | LaserSharp® Auto Focus, auto focus and manual focus | Fixed focus | |
Frame rate | 60 Hz or 9 Hz versions | 9 Hz | |
IFOV (spatial resolution) | 0.93 mRad | 7.6 mRad | |
IR-Fusion® Technology | AutoBlend continuous 0 % to 100 % | AutoBlend continuous 0 % to 100 % | |
Optional lenses | Wide angle, 2x and 4x telephoto, macro | | |
Temperature measurement range | -20 °C to +1000 °C (-4 °F to +1832 °F) | -20 °C to +400 °C (-4 °F to +752 °F) | |
Thermal Sensitivity | 50mK | 60mK | |
Minimum focus distance | With standard lens: 15 cm (6 in); with optional lenses: from 15 cm (6 in) to 1.5 m (5 ft) | | |
Wireless connectivity | Fluke Connect™ app compatible. Wireless connectivity to PC, iPhone® and iPad® (iOS 4s and later), Android™ 4.3 and up, and WiFi to LAN¹ | | |
Design | 240° rotating screen | | |
Thermal sensitivity (NETD) - best possible | 50mK | | |
Built-in digital camera (visible light) | 5 MP resolution for image and video recording | | |
Thermal sensitivity (NETD) | ≤ 0.05 °C at 30 °C target temp (50 mK) | | |