Fluke TiS60 Infrared Camera
Key features
- Fixed focus point and shoot infrared camera with 260x195 resolution (50,700 pixels)
- Captures quality images at a distance with a D:S of 417:1
- Offers five presets of IR-Fusion® with AutoBlend and PIP to help find problems fast
- Features standard and radiometric video recording
- Includes a built-in laser pointer
- Displays images on a 3.5 inch, 320x240 LCD
- Provides a temperature measurement range from -20 °C to 550 °C (–4 °F to 1022 °F)
- Digitally documents critical information along with the infrared image using IR-PhotoNotes™ or voice annotation
- Captures visible light images with built-in 5 megapixel industrial performance digital camera
- Includes a smart battery system that allows you to easily monitor your battery charge level with five-segment LED display
- Allows real-time communication by email from your smart phone with Fluke Connect®*
- Stores thousands of images—4 GB internal memory and included 4 GB micro SD card
Product overview: Fluke TiS60 Infrared Camera
Fluke TiS60 is the ultimate all-around industrial high-performance infrared camera
The Fluke TiS60 is a great choice for electrical, process control, HVAC, and building system troubleshooting. It is built rugged so you can take it anywhere. Capture more data on each target with standard and radiometric video. For example, capture the location of the equipment or the motor nameplate with the infrared image, using IR-PhotoNotes™ or voice annotation. Monitor high temperature processes up to +550 °C (1022 °F) and stream video to a PC or smartphone.
Its 260x195 resolution and distance-to-spot ratio of 417:1 help you capture quality images at a distance. And you can use IR-Fusion® AutoBlend™ and picture-in-picture (PIP) to blend a visible light image with an infrared image of the same target at five different levels to more easily locate problems. Plus, you can store thousands of images on the TiS60 with 4 GB internal memory and 4 GB more on the included micro SD card.
Collaborate from the field with Fluke Connect® connectivity
Because the TiS60 is Fluke Connect-enabled, you can share images in real-time¹ across teams and save time by creating and emailing reports from the jobsite. Capture multiple measurements and save them to the cloud with WiFi upload and free storage for up to 5GB with Fluke Cloud™.
See more and do more with Fluke Connect® SmartView® IR Analysis Reporting Software
Use Fluke Connnect SmartView software to analyze images from the TiS60 with graphical tools to quantify the severity of problems. When you're done analyzing you can easily generate a professional report complete with thermal images with the easy-to-follow report wizard to guide you step by step.
¹ Within your provider's wireless service area; Fluke Connect is not available in all countries
Specifications: Fluke TiS60 Infrared Camera
Key Features | |
IFOV (spatial resolution) | 2.4 mRad |
Detector resolution | 260x195 |
Field of view | 35.7 ° x 26.8 ° |
Distance to spot | 417:1 |
Wireless connectivity | Yes |
Fluke Connect® app compatible | Yes (where available) |
IR-Fusion® Technology | |
AutoBlend™ mode | 5 presets (0%, 25%, 50%, 75%, 100%) |
Picture-In-Picture (PIP) | 5 presets (0%, 25%, 50%, 75%, 100%) |
Focus system | Fixed focus, Minimum focus distance 0.45 m (1.5 ft) |
Ruggedized display | 3.5 inch (landscape) 320x240 LCD |
Rugged, ergonomic design for one-handed use | Yes |
Thermal sensitivity (NETD) | ≤ 0.08 °C at 30 °C target temp (80 mK) |
Temperature measurement range (not calibrated below -10 °C) | -20 °C to +550 °C (–4 °F to 1022 °F) |
Level and span | Smooth auto and manual scaling |
Fast auto toggle between manual and auto modes | Yes |
Fast auto-rescale in manual mode | Yes |
Minimum span (manual mode) | 2.5 °C |
Minimum span (auto mode) | 5 °C |
Built-in digital camera (visible light) | 5 MP |
Frame rate | 9 Hz |
Laser pointer | Yes |
Data storage and Image Capture | |
Extensive SD memory system | Internal 4 GB memory and 4 GB removable micro SD card |
Image capture, review, save mechanism | One-handed image capture, review, and save capability |
Image file formats | Non-radiometric (.bmp) or (.jpeg) or fully-radiometric (.is2); No analysis software required for non-radiometric (.bmp, .jpg) files |
Instant upload | Instantly upload captured images to Fluke Connect server with the use of a WiFi connection |
Memory review | Thumbnail review |
Software | SmartView® software - full analysis and reporting software and Fluke Connect® (where available) |
Export file formats with SmartView® software | BMP, DIB, GIF, JPE, JFIF, JPEG, JPG, PNG, TIF, and TIFF |
Voice annotation | Yes, Bluetooth Headset (sold separately) |
IR-PhotoNotes™ | Yes (3 images) |
Standard video recording | Yes |
Radiometric video recording | Yes |
Video file formats | Non-radiometric (MPEG - encoded .AVI) and fully radiometric (.IS3) |
Streaming video (remote display) | Yes |
Battery | |
Batteries (field-replaceable, rechargeable) | Two lithium ion smart battery packs with five-segment LED display to show charge level |
Battery life | Four+ hours |
Battery charge time | 2.5 hours to full charge |
Battery charging system | Two-bay battery charger or in-imager charging |
AC operation | AC operation with included power supply (100 V AC to 240 V AC, 50/60 Hz) |
Temperature Measurement | |
Accuracy | ±2 °C or 2% (at 25 °C nominal, whichever is greater) |
On-screen emissivity correction | Yes (both value and table) |
On-screen reflected background temperature compensation | Yes |
On-screen transmission correction | Yes |
Color Palettes | |
Standard palettes | 8: Ironbow, Blue-Red, High-Contrast, Amber, Amber Inverted, Hot Metal, Grayscale, Grayscale Inverted |
Ultra Contrast™ palettes | 8: Ironbow Ultra, Blue-Red Ultra, High-Contrast Ultra, Amber Ultra, Amber Inverted Ultra, Hot Metal Ultra, Grayscale Ultra, Grayscale Inverted Ultra |
General Specifications | |
Color alarms (temperature alarms) | High temperature, low temperature, Isotherms |
Infrared spectral band | 7.5 μm to 14 μm |
Operating temperature | -10 °C to +50 °C (14 °F to 122 °F) |
Storage temperature | -20 °C to +50 °C (-4 °F to 122 °F) |
Relative humidity | 10% to 95%, non-condensing |
Center-point temperature measurement | Yes |
Spot temperature | Yes |
User-definable spot markers | 3 |
Center box | Expandable-contractible measurement box with MIN-MAX-AVG temp |
Safety standards | EN 61010-1: CAT none, pollution degree 2, EN 60825-1: Class 2, EN 60529, EN 62133 (lithium battery) |
Electromagnetic compatibility | EN 61326-1:2006, EN 55011: Class A, EN 61000-4-2, EN 61000-4-3 |
C Tick | IEC/EN 61326-1 |
US FCC | EN61326-1; FCC Part 5, EN 55011: Class A, EN 61000-4-2, EN 61000-4-3 |
Vibration and shock | 2G, IEC 68-2-6 and 25G, IEC 68-2-29 |
Drop | Engineered to withstand 2 m (6.5 ft) drop |
Size (H x W x L) | 26.7 x 10.1 x 14.5 cm (10.5 x 4.0 x 5.7 in) |
Weight (battery included) | Fixed focus .72 kg (1.6 lb), Manual focus .77 kg (1.7 lb) |
Enclosure rating | IP54 (protected against dust, limited ingress; protection against water spray from all directions) |
Warranty | Two-years (standard), extended warranties are available |
Recommended calibration cycle | Two-years (assumes normal operation and normal aging) |
Supported languages | Czech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, and Turkish |
Models: Fluke TiS60 Infrared Camera
Includes:
- Thermal imager
- AC charger/power supply with mains adapters for battery charging and AC operation
- Two-bay smart battery charger and 2 lithium ion smart batteries
- USB cable
- Micro SD Card
- Adjustable hand strap
- Rugged, hard carrying case
- Soft transport bag
- Statement of factory calibration
- Quick start guide
- Safety sheet
Manuals + resources: Fluke TiS60 Infrared Camera
- TiS10, TiS20, TiS40, TiS45, TIS50, TiS60, TiS65, TiS75 | Users manual
- TiS10, TiS20, TiS40, TiS45, TIS50, TiS60, TiS65, TiS75 | Users manual supplement
- TiS10, TiS20, TiS40, TiS45, TiS50, TiS55, TiS60, TiS65 | Quick reference guide
- TiS10, TiS20, TiS40, TiS45, TiS50, TiS55, TiS60, TiS65, TiS75 | Statement of memory volatility
- TiS10, TiS20, TiS40, TiS45, TiS50, TiS55, TiS60, TiS65, TiS75 | Safety sheet