Fluke 27 II Rugged Digital Multimeter
Compare products: digital multimeters
- Fluke 113 Digital Multimeter
- Fluke 114 Electrical Multimeter
- Fluke 115 Field Technicians Digital Multimeter
- Fluke 116 Digital HVAC Multimeter
- Fluke 117 Electrician's Multimeter with Non-Contact Voltage
- Fluke 175 True-RMS Digital Multimeter
- Fluke 177 True-RMS Digital Multimeter
- Fluke 179 True-RMS Digital Multimeter
- Fluke 87V Industrial Multimeter
- Fluke 87V MAX True-rms Digital Multimeter
- Fluke 88V Deluxe Automotive Multimeter
- Fluke 83V Average Responding Industrial Multimeter
- Fluke 287 True-RMS Electronics Logging Multimeter
- Fluke 289 True-RMS Data Logging Multimeter
- Fluke 233 Remote Display Digital Multimeter
- Fluke 279 FC True-rms Thermal Multimeter
- Fluke 28 II Rugged Digital Multimeter
- Fluke 28 II Ex Intrinsically Safe True RMS Digital Multimeter
Key features
- Measure up to 1000 V AC and DC
- Measure up to 10 A (20 A for 30 seconds)
- 10,000 μF capacitance range
- Frequency to 200 kHz
- Extended AC voltage bandwidth – 40 Hz to 30 kHz
- Resistance, continuity and diode test
- Min/Max and average recording to capture variations automatically
Sale ends soon.
Shop now!
DAYS
HR
MIN
SEC
A$1,042.80
Product overview: Fluke 27 II Rugged Digital Multimeter
The standard for rugged
The Fluke 27 II Digital Multimeter define a the standard for operating in harsh conditions with the features and accuracy to troubleshoot most electrical problems. Both meters have IP 67 (waterproof and dustproof) rating, MSHA approvals, extended operating temperature range of -15 °C to +55 °C (5 °F to 131 °F, -40 °C for up to 20 minutes) and 95% humidity, and have been designed and tested to withstand a 3 m (10 ft) drop. The Fluke 20 Series Multimeters are built to work in the toughest environments.
What's in the box:
- Fluke 27 II Rugged Digital Multimeter
- Holster
- (1 pair) Test Leads
- (1 pair) Alligator Clips
- 3 AA batteries (installed)
- Quick reference guide
Specifications: Fluke 27 II Rugged Digital Multimeter
Accuracy Specifications | ||
DC voltage | Range | 0.1 mV to 1000 V |
Accuracy | 0.1% + 1 | |
AC voltage | Range | 0.1 mV to 1000 V |
Accuracy | 0.5% + 3 | |
DC current | Range | 0.1 μA to 10 A |
Accuracy | 0.2% + 4 | |
AC current | Range | 0.1 μA to 10 A |
Accuracy | 1.5% + 2 | |
Resistance | Range | 0.1 Ω to 50 MΩ |
Display counts | 6000 | |
Capacitance | 1 nF to 9999 μF | |
Frequency | 0.5 Hz to 199.99 kHz | |
Compliance | CAT IV 600 V , CAT III 1000V | |
IP rating | IP 67 | |
Power | Three AA batteries | |
Battery life | 800 hours | |
General Specifications | ||
Display | Bar graph/backlight | Yes/Yes |
Data storage | Min/Max/Avg | Yes |
Reading hold | Yes | |
Other features | Relative readings (zero) | Yes |
Battery type | Three AA batteries | |
Warranty and protection | Safety rating | CAT IV 600 V/CAT III 1000 V |
Mine safety | MSHA Approved | |
External protection | Rubber holster | |
Drop test | 10 feet drop test | |
Dustproof/waterproof | Yes, IP 67 rated | |
Warranty | Limited lifetime | |
Size (H x W x L) with holster | 6.35 x 10.0 x 19.81 cm (2.5 x 3.93 x 7.8 in) | |
Weight with holster | 698.5 g (1.54 lb) |
Models: Fluke 27 II Rugged Digital Multimeter
Fluke 27 II
Fluke 27 II Rugged Digital Multimeter
Includes:
- Holster
- Test Leads
- Alligator Clips
- Printed getting started manual
- CD ROM manual
- 3 AA batteries