Fluke i1010 AC/DC Current Clamp
Fluke i1010 AC/DC Current Clamp is rated out of 5 by 3.
Key features
- The Fluke i1010 AC/DC current clamp is a battery-powered Hall-effect probe that extend the current ranges of Fluke tools, measuring DC current from 1 A to 1000 A and AC current from 1 A to 600A.
- Provides accurate current reading without breaking the circuit.
- Compatible with most Fluke multimeters.
- CAT III 600 V safety rating
Product overview: Fluke i1010 AC/DC Current Clamp
Fluke current clamps extend the current ranges of Fluke tools. The Fluke i1010 AC/DC current clamp is highly reliable, measures 1 A to 1000 A and provides accurate current reading without breaking the circuit. This clamp measures both ac and dc current with a large jaw, battery-powered Hall-effect probe that gives access to difficult to reach areas. Compatible with most Fluke multimeters.
Specifications: Fluke i1010 AC/DC Current Clamp
Specifications | |
Measurement type | Hall sensor |
Nominal current range | 600 A, AC 1000 A, DC |
Continuous current range | 1 A - 600 A, AC 1 A - 1000 A, DC |
Maximum non-desctructive current | 1000 A |
Lowest measureable current | 0.5 A |
Basic accuracy | 2% + 0.5 A (% reading + floorspec) |
Useable frequency | DC - 10 kHz |
Output level(s) | 1 mV/A |
Zero error adjustment | Yes |
Safety Specifications | |
Safety | CAT III, 600 V |
Maximum voltage | 600 V |
Mechanical and General Specifications | |
Warranty | 1 year |
Battery life | 9 V, 60 h |
Maximum conductor diameter | 30 mm 2 x 25 mm |
Output cable length | 1.6 m |
Shrouded banana plugs | Yes |
Models: Fluke i1010 AC/DC Current Clamp
Fluke i1010
Fluke i1010 AC/DC Current Clamp
dear please i have fluke 289 and i want to purchase ac/dc current clamp i1010, does i1010 compatibility with Avometer fluke 289 , we can record the reading and take all features in fluke 289
Yes, the Fluke i1010 AC/DC Current Clamp compatible with the Fluke 289.
Date published: 2024-09-01
It fit with the 117 multimeter?
Rated 5 out of 5 by MR Smith from Quite frankly the best I have owned the Fluke i1010 since it came out, and require all of my technicians to own one and keep it in good condition. Honestly, it's slicker than boiled okra.
Date published: 2023-10-26
Rated 5 out of 5 by DKHsfl from Well crafted upgrade In leu of repairing my aged Fluke 80i-1010 I was offered an i1010 current clamp. I could not be more pleased with the design and construction of the clamp jaws and battery arrangement. We have used it extensively in the last few months to monitor servo installation and aid RVAT troubleshooting. As an added benefit the high visibility yellow and red makes it easier to find in the bottom of my instrument bag.
Date published: 2016-12-07