Fluke 115 Field Technicians Digital Multimeter
Compare products: digital multimeters
- Fluke 113 Digital Multimeter
- Fluke 114 Electrical Multimeter
- Fluke 116 Digital HVAC Multimeter
- Fluke 117 Electrician's Multimeter with Non-Contact Voltage
- Fluke 175 True-RMS Digital Multimeter
- Fluke 177 True-RMS Digital Multimeter
- Fluke 179 True-RMS Digital Multimeter
- Fluke 87V Industrial Multimeter
- Fluke 87V MAX True-rms Digital Multimeter
- Fluke 88V Deluxe Automotive Multimeter
- Fluke 83V Average Responding Industrial Multimeter
- Fluke 287 True-RMS Electronics Logging Multimeter
- Fluke 289 True-RMS Data Logging Multimeter
- Fluke 233 Remote Display Digital Multimeter
- Fluke 279 FC True-rms Thermal Multimeter
- Fluke 27 II Rugged Digital Multimeter
- Fluke 28 II Rugged Digital Multimeter
- Fluke 28 II Ex Intrinsically Safe True RMS Digital Multimeter
Key features
- Compact True-rms digital multimeter for field service
- Includes: meter, holster, TL75 test lead set
- Easy one-handed operation of the meter
- Min/Max/Average to record signal fluctuations
Sale ends soon.
Shop now!
DAYS
HR
MIN
SEC
A$388.30
Product overview: Fluke 115 Field Technicians Digital Multimeter
Compact true-rms meter for field service technicians
The Fluke 115 field technician’s digital multimeter measures True-rms voltage and current with plus resistance, continuity, frequency, and capacitance to meet the needs of a wide variety of field service technicians.
The 115 digital multimeter offers the users one-handed operation and a backlit display. The large, easy-to-read digits offer a 6000-count resolution. The 115 provides Min/Max/Average with elapsed time to record signal fluctuations. It also measures:
- AC and DC voltage to 600V,
- AC and DC current to 10 A (20 A overload for 30-seconds max).
What's in the box:
- Digital multimeter
- Holster
- Installed 9V battery
- TL75 test lead set
- Quick Reference Guide
Specifications: Fluke 115 Field Technicians Digital Multimeter
Specifications | ||
Accuracy Specifications | ||
DC millivolts | Range/resolution | 600.0 mV / 0.1 mV |
Accuracy | ± ([% of reading] + [counts]): 0.5% + 2 | |
DC volts | Range/resolution | 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V |
Accuracy | ± ([% of reading] + [counts]): 0.5% + 2 | |
AC millivolts1 True RMS | Range/resolution | 600.0 mV / 0.1 mV |
Accuracy | 1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz) | |
AC volts1 True RMS | Range/resolution | 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V |
Accuracy | 1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz) | |
Continuity | Range/resolution | 600 Ω / 1 Ω |
Accuracy | Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of 500 μs or longer. | |
Ohms | Range/resolution | 600.0 Ω / 0.1 Ω 6.000 kΩ / 0.001 kΩ 60.00 kΩ / 0.01 kΩ 600.0 kΩ / 0.1 kΩ 6.000 MΩ / 0.001 MΩ |
Accuracy | 0.9% + 1 | |
Range/resolution | 40.00 MΩ / 0.01 MΩ | |
Accuracy | 5% + 2 | |
Diode test | Range/resolution | 2.00 V / 0.001 V |
Accuracy | 0.9% + 2 | |
Capacitance | Range/resolution | 1000 nF / 1 nF 10.00 μF / 0.01 μF 100.0 μF / 0.1 μF 9999 μF / 1 μF 100 μF to 1000 μF |
Accuracy | 1.9% + 2 | |
Range/resolution | > 1000 μF | |
Accuracy | 5% + 20% | |
Lo-Z capacitance | Range | 1 nF to 500 μF |
Accuracy | 10% + 2 typical | |
AC amps True RMS (45 Hz to 500Hz) | Range/resolution | 6.000 A / 0.001 A 10.00 A / 0.01 A |
Accuracy | 1.5% + 3 20 A overload for 30-seconds max | |
DC amps | Range/resolution | 6.000 A / 0.001 A 10.00 A / 0.01 A |
Accuracy | 1.0% + 3 20 A overload for 30-seconds max | |
Hz (V or A input)2 | Range/resolution | 99.99 Hz / 0.01 Hz 999.9 Hz / 0.01 Hz 9.999 kHz / 0.001 kHz 50.00 kHz / 0.01 kHz |
Accuracy | 0.1% + 2 | |
1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V. 2. Frequency is AC coupled, 5Hz to 30 kHz for AC voltage. 2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe. 2. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current. 2. Temperature Range/Resolution: -40℉ to 752℉ / 0.2℉. |
General Specifications | |
Maximum voltage between any terminal and earth ground | 600 V |
Safety | IEC 61010-1: Pollution Degree 2 IEC 61010-2-033: CAT III 600V |
Display | Digital: 6,000 counts, updates 4 per second |
Bar graph | 33 segments, updates 32 per second |
Operating temperature | -10℃ to + 50℃ |
Storage temperature | -40℃ to + 60℃ |
Battery type | 9 volt Alkaline, IEC 6LR61 |
Battery life | 400 hours typical, without backlight |
Size | 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in) |
Weight | 550 g |
Warranty | 3 years |
Models: Fluke 115 Field Technicians Digital Multimeter
FLUKE-115
Fluke 115 Digital Multimeter
Includes:
- Holster
- Installed 9V battery
- TL75 test lead set
- User manual