Fluke 393 FC Solar Clamp Meter CAT III 1500 V

  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 128.03ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • 393 FC CAT III 1500 V True-rms Clamp Meter
  • The Fluke 393 clamp meter has a very thin jaw for cramped combiner boxes, but still clamps around a 34 mm cable.
  • Fluke 393 FC clamp calculates and dsiplay dc power (kVA) enerated by a solar panel
  • Measurements sent to a smartphone and the cloud via Fluke Connect software.
  • Video Player is loading.
    Current Time 0:00
    Duration 0:00
    Loaded: 0%
    Stream Type LIVE
    Remaining Time 0:00
     
    1x
      • Chapters
      • descriptions off, selected
      • en (Main), selected
    1. 393 FC CAT III 1500 V True-rms Clamp Meter
    2. The Fluke 393 clamp meter has a very thin jaw for cramped combiner boxes, but still clamps around a 34 mm cable.
    3. Fluke 393 FC clamp calculates and dsiplay dc power (kVA) enerated by a solar panel
    4. Measurements sent to a smartphone and the cloud via Fluke Connect software.
    5. Fluke 393 FC CAT III 1500 V True-rms Clamp Meter

    Key features

    • Measure safely with CAT III 1500 V rated clamp meter
    • Thin jaw for access to cables in crowded combiner boxes
    • Sturdy IP54 rated for outdoor use and solar installation
    • Work efficiently with dc power measurement, audio polarity and visual continuity
    In stock
    A$1,541.10
    Tax included where applicable
    Genuine Fluke Product
    Free shipping

    Product overview: Fluke 393 FC Solar Clamp Meter CAT III 1500 V

    Fluke Solar Solutions

    The 393 FC CAT III 1500 V True-rms Clamp Meter with iFlex is designed for solar photovoltaic (PV) installation technicians and maintenance professionals who work in high voltage dc environments: PV arrays, wind power, electric railways, data centers battery banks for uninterruptible power supplies. The clamp will measure up to 1500 V dc, 1000 V ac, and up to 999.9 A dc or ac through the clamp jaw. The included iFlex flexible current probe extended ac current measurements up to 2500 amps. This clamp has a thin jaw, giving you access to cables in crowded combiner boxes. Test leads are designed with your work in mind, and are also rated to CAT III 1500 V dc.

     

    Key functions of the solar clamp meter:

    • IP54 rated, ideal for work outdoors including PV panel testing
    • DC power measurement, showing readings in kVA
    • Audio Polarity indicator helps prevent accidental miswires
    • Visual Continuity turns provide a bright green light in the display, ideal when working in dark and noisy environments
    • Logging and reporting of test results via Fluke Connect software
    • When measuring ac current the included iFlex flexible current probe gives you unparalleled access to cable is tight spaces.  The iFlex probe can be twisted through extremely small spaces and provide accurate current measurements.


    The world's first CAT III 1500 V true-RMS solar clamp meter

    What's in the box:

    • Fluke 393 FC CAT III 1500 V TRMS clamp meter
    • Test leads, CAT III 1500 V rated, right angle plugs, with safety caps
    • iFlex 18 inch flexible current probe
    • TPAK magnetic hanging strap
    • Premium carrying case
    • 3-year warranty

    Specifications: Fluke 393 FC Solar Clamp Meter CAT III 1500 V

    Specifications:   
    General   
    Maximum voltage between any Terminal and Earth Ground  
    AC1000 V  
    DC1500 V  
    Batteries2 AA IEC LR6 alkaline  
    DisplayDual display with backlight  
    Automatic Power Off20 minutes  
    Electrical   
    Accuracy   
    Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 %. Accuracy specifications take the form of: ±([% of Reading] + [Number of Least Significant Digits]).
    Temperature CoefficientsAdd 0.1 x specified accuracy for each °C > 28 °C or < 18 °C
    AC Current: Jaw   
    Range999.9 A  
    Resolution0.1 A  
    Accuracy2 % + 5 digits (10 Hz to 100 Hz) 
     2.5 % + 5 digits (100 Hz to 500 Hz) 
    Crest Factor (50/60 Hz)2.5 @600.0 A  
     3.0 @500.0 A  
     1.42 @999.9 A  
     Add 2 % for C.F. >2  
    AC Current: Flexible Current Probe   
    Range999.9 A  
     2500 A  
    Resolution0.1 A (≤999.9 A)  
     1 A (≤2500 A)  
    Accuracy3 % RD + 5 digits (10 Hz to 500 Hz) 
    Crest Factor (50/60Hz)2.5 @1400 A  
     3.0 @1100 A  
     1.42@2500 A  
     Add 2 % for C.F. >2  
    Position Sensitivity   
    NEC symbol
    Distance from Optimumi2500-10 Flexi2500-18 FlexError
    A0.5 in (12.7 mm)1.4 in (35.6 mm)±0.5 %
    B0.8 in (20.3 mm)2.0 in (50.8 mm)±1.0 %
    C1.4 in (35.6 mm)2.5 in (63.5 mm)±2.0 %
    Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.
        
    DC Current   
    Range999.9 A  
    Resolution0.1 A  
    Accuracy2 % RD + 5 digits[1]  
     [1] When using the ZERO (B) function to compensate for offsets.
    AC Voltage   
    Range600.0 V  
     1000 V  
    Resolution0.1 V (≤600.0 V)  
     1 V (≤1000 V)  
    Accuracy1 % RD + 5 digits (20 Hz to 500 Hz) 
    DC Voltage   
    Range600.0 V  
     1500 V  
    Resolution0.1 V (≤600.0 V)  
     1 V (≤1500 V)  
    Accuracy1 % RD + 5 digits  
    mV dc   
    Range500.0 mV  
    Resolution0.1 mV  
    Accuracy1 % RD + 5 digits  
    Amps Frequency: Jaw   
    Range5.0 Hz to 500.0 Hz  
    Resolution0.1 Hz  
    Accuracy0.5 % RD + 5 digits  
    Trigger Level5 Hz to 10 Hz, ≥10 A  
     10 Hz to 100 Hz, ≥5 A  
     100 Hz to 500 Hz, ≥10 A  
    Amps Frequency: Flexible Current Probe   
    Range5.0 Hz to 500.0 Hz  
    Resolution0.1 Hz  
    Accuracy0.5 % RD + 5 digits  
    Trigger Level5 Hz to 20 Hz, ≥25 A  
     20 Hz to 100 Hz, ≥20 A  
     100 Hz to 500 Hz, ≥25 A  
    Voltage Frequency   
    Range5.0 Hz to 500.0 Hz  
    Resolution0.1 Hz  
    Accuracy0.5 % RD + 5 digits  
    Trigger Level5 Hz to 20 Hz, ≥5 V  
     20 Hz to 100 Hz, ≥5 V  
     100 Hz to 500 Hz, ≥10 V  
    DC Power   
    Range600.0 kVA (600.0 V dc range)  
     1500 kVA (1500 V dc range)  
    Resolution0.1 kVA  
     1 kVA  
    Accuracy2 % RD + 2.0 kVA  
     2 % RD + 20 kVA  
    Resistance   
    Range600.0 Ω  
     6000 Ω  
     60.00 kΩ  
    Resolution0.1 Ω (≤600.0 Ω)  
     1 Ω (≤6000 Ω)  
     0.01 kΩ (≤60.00 kΩ)  
    Accuracy1 % RD + 5 digits  
    Capacitance   
    Range100.0 μF  
     1000 μF  
    Resolution0.1 μF (≤100.0 μF)  
     1 μF (≤1000 μF)  
    Accuracy1 % RD + 5 digits  
    Inrush Trigger Level5 A  
    Mechanical   
    Size (L x W x H)281 mm x 84 mm x 49 mm  
    Weight (with batteries)520 g  
    Jaw Opening34 mm  
    Flexible Current Probe Diameter7.5 mm  
    Flexible Current Probe Cable Length   
    (head to electronics connector)1.8 m  
    Environmental   
    Operating Temperature-10 °C to 50 °C  
    Storage Temperature-40 °C to 60 °C  
    Operating HumidityNon condensing (<10°C)  
     ≤90 % RH (at 10 °C to 30 °C)  
     ≤75 % RH (at 30 °C to 40 °C)  
     ≤45 % RH (at 40 °C to 50 °C)  
    Operating Altitude2000 m  
    Storage Altitude12 000 m  
    Ingress Protection (IP) RatingIEC 60529: IP54 non-operating  
    Electromagnetic Compatibility (EMC)   
    InternationalIEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 CISPR 11: Group 1, Class A
     Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.
    Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances.
    Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments.
    Korea (KCC)Class A equipment (Industrial Broadcast & Communications Equipment)
     Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
    USA (FCC)47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
    Safety   
    GeneralIEC 61010-1, Pollution Degree 2 
    MeasurementIEC 61010-2-032: CAT III 1500 V / CAT IV 600 V 
     IEC 61010-2-033: CAT III 1500 V / CAT IV 600 V 
    Wireless Radio   
    Radio frequency certificationFCC ID: T68-FBLE, IC: 6627A-FBLE 
    Wireless Radio Frequency Range2400 MHz to 2483.5 MHz  
    Output Power<100 mW  
    SIMPLIFIED EU DECLARATION OF CONFORMITY  
    Hereby, Fluke declares that the radio equipment contained in this Product is in compliance with Directive 2014/53/EU.
    The full text of the EU declaration is available at the following Internet address:  
    www.fluke.com/en-us/declaration-of-conformity   

    Models: Fluke 393 FC Solar Clamp Meter CAT III 1500 V

    393 FC
    393 FC CAT III 1500 V True-rms Clamp Meter with iFlex

    Find a distributor

    Included:

    • Fluke 393 FC CAT III 1500 V True-rms Clamp Meter with iFlex
    • Test leads, CAT III 1500 V rated, right angle plugs, with safety caps
    • iFlex 18 inch flexible current probe
    • TPAK magnetic hanging strap
    • Premium carrying case
    • 3-year warranty
    • bvseo_sdk, p_sdk, 3.2.1
    • CLOUD, getContent, 129.51ms
    • QUESTIONS, PRODUCT
    • bvseo-msg: HTTP status code of 404 was returned;
    • bvseo_sdk, p_sdk, 3.2.1
    • CLOUD, getReviews, 23.93ms
    • REVIEWS, PRODUCT
    • bvseo-msg: HTTP status code of 404 was returned;
    Please enable cookies to view product reviews.