Kit combinado Fluke 3000 FC/TPAK - Inclui medidor e suporte magnético
Características principais
The Fluke 3000 FC has features and functions needed to troubleshoot your equipment and plant.
- True-rms AC voltage and current for accurate measurements on non-linear loads
- Large digit display with analog bargraph
- Display backlight for work in dark areas
- Capacitance
- Records minimum and maximum values to aid in troubleshooting
- Free your hands with the magnetic hanger included in this combo kit
- 3 year warranty
- Plus, the Fluke Connect wireless enabled modules measure AC, DC and AC+DC voltage, AC and DC current, plus temperature, all of which display on the Fluke 3000 FC Series Wireless Multimeter. Choose a standard clamp or flexible clamp to measure AC current. Mix and match modules to suit your unique measurement needs. Read the primary measurement on the main display and up to three modules at any one time. Modules are available separately or as part of Fluke Connect kits
Descrição do produto: Kit combinado Fluke 3000 FC/TPAK - Inclui medidor e suporte magnético
Agora compatível com o aplicativo móvel Fluke Connect®
O Multímetro Fluke 3000 Série FC coloca ferramentas de teste sem fio, não o seu corpo, próximos de quadros elétricos em funcionamento. Melhore a segurança e a eficiência usando esse testador.
Todos os registros, diretamente do campo de trabalho. O Multímetro Sem fio True-RMS Fluke 3000 FC com aplicativo Fluke Connect e chamada de vídeo ShareLive™.
Com sua precisão, confiabilidade e facilidade de uso, o Multímetro Sem fio Fluke 3000 FC é a solução ideal para técnicos profissionais. Testado independentemente para uso seguro nos ambientes CAT IV 600V/ CAT III 1.000 V, o Fluke 3000 FC tem todos os recursos que você precisa para solucionar problemas e reparar muitas falhas em sistemas elétricos e eletrônicos.
O Fluke 3000 FC fornece medições de tensão e corrente True-RMS, resolução de 6000 contagens, variação manual e automática e fornece medições de frequência, capacidade, resistência, continuidade e diodo. Além disso, o Fluke 3000 FC fornece uma precisão básica mais alta de 0,09%, um visor digital mostrando até três medições a partir dos módulos remotos, e uma iluminação de fundo totalmente branca.
Trabalhe em segurança próximo de quadros elétricos usando menos equipamentos de proteção pessoal
O Multímetro Sem fio True-RMS Fluke 3000 FC e as ferramentas de teste sem fio Fluke Connect colocam as ferramentas, e não o seu corpo, próximo de quadros elétricos em funcionamento. É simples. Apenas desenergize o gabinete, abra o quadro usando equipamento de proteção pessoal e conecte os módulos remotos, sejam módulos de tensão, pinças amperimétricas e loops de corrente flexíveis ou termômetros. Em seguida, faça a leitura dos resultados no Multímetro Sem fio 3000 FC a partir de uma distância segura. Você pode exibir a medição do medidor, além das leituras de até 3 módulos sem fio, enquanto reduz o risco de arco elétrico ao separar você de situações de medições perigosas.
Melhor ainda, o Multímetro Sem fio Fluke 3000 Série FC pode enviar dados de medição para seu smartphone, para que você possa salvar e compartilhar medições de campo com sua equipe a qualquer momento, de qualquer lugar.
Não fique em situações desagradáveis ao procurar eventos inter-relacionados
Tempo é tudo ao tentar encontrar a causa de um problema complexo. Frequentemente, você precisa fazer uma medição em um local e ver a atividade em outra parte do sistema ao mesmo tempo. Nós resolvemos esse problema com o Fluke Connect - conecte seus módulos remotos em um local e, depois, faça suas medições a até 20 metros de distância com o multímetro Fluke 3000 FC. Você poderá ver a interação entre seus pontos de ensaio remoto em uma única tela, em tempo real. Você pode até mesmo baixar os dados para um PC para fazer outras análises.
Outros recursos do Fluke Connect e do Multímetro 3000 FC.
- Adicione seu laptop e passe de registrar para analisar e diagnosticar.
- Faça registros ao longo do tempo usando os módulos sem fio Fluke Connect e monitore as alterações de carga do circuito por uma hora, um turno ou uma semana.
- Use o adaptador USB sem fio Fluke Connect para coletar os dados registrados dos módulos remotos passando por um módulo em funcionamento e baixando os dados registrados.
- Execute análises com seu PC e compartilhe os resultados usando o armazenamento Fluke Cloud™ e a chamada de vídeo ShareLive™. Visualize dados ou gráficos para obter informações de cada um dos membros da equipe.
Especificações: Kit combinado Fluke 3000 FC/TPAK - Inclui medidor e suporte magnético
AC Voltage | |||
Range¹ / resolution | 600.0 mV / 0.1 mV 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V 1000 V / 1 V | ||
Accuracy2 3 4 | 45 Hz to 500 Hz | 1.0% + 3 | |
500 Hz to 1 kHz | 2.0% + 3 | ||
1. AC voltage ranges are specified from 1% of range to 100% of range. 2. Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V. 3. For non-sinusoidial waveforms, add ± (2% of reading + 2% full scale) typical, for crest factor up to 3. 4. Do not exceed 107 V-Hz. | |||
DC Voltage, Continuity, Resistance, Diode Test and Capacitance | |||
mV | Range / resolution | 600.0 mV / 0.1 mV | |
Accuracy | 0.09% + 2 | ||
V | Range / resolution | 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V 1000 V / 1 V | |
Accuracy | 0.09% + 2 0.15% + 2 | ||
))) | Range / resolution | 600 Ω / 1 Ω | |
Accuracy | Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer. | ||
Ω | Range / resolution | 600.0 Ω / 0.1 Ω 6.000 kΩ / 0.001 kΩ 60.00 kΩ / 0.01 kΩ 60.00 kΩ / 0.1 kΩ 600.0 kΩ / 0.001 MΩ 50.00 MΩ / 0.01 MΩ | |
Accuracy | 0.5% + 2 0.5% + 1 1.5% + 3 | ||
Diode test | Range / resolution | 2.000 V / 0.001 V | |
Accuracy | 1% + 2 | ||
µF | Range / resolution | 1000 nF / 1 nF 10.00 μF / 0.01 μF 100.0 μF / 0.1 μF 9999 μF1 / 1 μF | |
Accuracy | 1.2% + 2 10% typical | ||
1. In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2% + 2. | |||
AC and DC Current | |||
mA AC (45 Hz to 1 kHz) | Range1 / resolution | 60.00 mA / 0.01 mA 400.0 mA3 / 0.1 mA | |
Accuracy | 1.5% + 3 | ||
mA DC2 | Range1 / resolution | 60.00 mA / 0.01 mA 400.0 mA3 / 0.1 mA | |
Accuracy | 0.5% + 3 | ||
1. All AC current ranges are specified from 5% of range to 100% of range. 2. Input burden voltage (typical): 400 mA input 2 mV/mA. 3. 400.0 mA accuracy specified up to 600 mA overload. | |||
Frequency | |||
Range / resolution | 99.99 Hz / 0.01 Hz 999.9 Hz / 0.1 Hz 9.999 kHz / 0.001 kHz 99.99 kHz / 0.01 kHz | ||
Accuracy1 | 0.1% + 1 | ||
1. Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps. | |||
Input Characteristics | |||
Overload protection | 1100 V RMS | ||
Input impedance (nominal) | > 10 MΩ < 100 pF | ||
Common mode rejection ratio (1 kΩ unbalance) | > 120 dB at DC, 50 Hz or 60 Hz | ||
Normal mode rejection | > 60 dB at 50 Hz or 60 Hz | ||
Overload protection | 1100 V RMS | ||
Input impedance (nominal) | > 10 MΩ < 100 pF | ||
Common mode rejection ratio (1 kΩ unbalance) | > 60 dB, DC to 60 Hz | ||
Normal mode rejection | > 60 dB at 50 Hz or 60 Hz | ||
Overload protection | 1100 V RMS | ||
Input impedance (nominal) | > 10 MΩ < 100 pF | ||
Common mode rejection ratio (1 kΩ unbalance) | > 120 dB at DC, 50 Hz or 60 Hz | ||
Normal mode rejection | > 60 dB at 50 Hz or 60 Hz | ||
Open Circuit Test Voltage | |||
Overload protection | 1100 V RMS | ||
Input impedance (nominal) | < 2.7 V DC | ||
Full scale voltage to 6 MΩ Full scale voltage 50 MΩ | < 0.7 V DC < 0.9 V DC | ||
Typical short circuit current | < 350 mA | ||
Overload protection | 1100 V RMS | ||
Input impedance (nominal) | < 2.7 V DC | ||
Full scale voltage to 6 MΩ Full scale voltage 50 MΩ | 2.000 V DC | ||
Typical short circuit current | < 1.1 mA | ||
mA Function | |||
Overload protection | Fused, 44/100 A, 1000 V FAST Fuse | ||
Overload | 600 mA overload for 2 minutes maximum, 10 minutes rest minimum | ||
MIN/MAX Recording Accuracy | |||
DC functions | ± 12 counts for changes > 350 mS in duration. | ||
AC functions | ± 40 counts for changes > 900 mS in duration. | ||
General Specifications | |||
Maximum voltage between any terminal and earth ground | 1000 V DC or AC RMS | ||
Ω fuse protection from A inputs | 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only | ||
Display (LCD) | Update rate | 4/sec | |
Volts, amps, ohms | 6000 counts | ||
Frequency | 10,000 counts | ||
Capacitance | 1,000 counts | ||
Battery type | Three AA Alkaline batteries, NEDA 15A IEC LR6 | ||
Battery life | 250 hours minimum | ||
RF communications | 2.4 GHZ ISM Band | ||
RF communication range | Open air, unobstructed | Up to 20m | |
Obstructed, sheetrock wall | Up to 6.5m | ||
Obstructed, concrete wall, or steel electrical enclosure | Up to 3.5m | ||
Temperature | Operating | -10°C to 50°C | |
Storage | -40°C to 60°C | ||
Temperature coefficient | 0.1 X (specified accuracy) / °C (< 18°C or > 28°C) | ||
Relative humidity | 0% to 90% (0°C to 35°C) 0% to 75% (35°C to 40°C) 0% to 45% (40°C to 50°C) | ||
Altitude | Operating | 2,000 m | |
Storage | 12,000 m | ||
Electromagnetic compatibility EMI, RFI, EMC, RF | EN 61326–1:2006, EN 61326–2–2:2006 ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489 V1.8.1:2008 FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249 FCCID : FCC: T68–FDMMBLE IC: 6627A–FDMMBLE | ||
Safety compliance | ANSI / ISA 61010–1 / (82.02.01): 3rd edition CAN / CSA-C22.2 No 61010-1-12: 3rd edition UL 61010–1: 3rd edition IEC / EN 61010–1:2010 | ||
Certifications | CSA, FCC, CE | ||
Ingress Protection (IP) rating | IP54 | ||
Pollution Degree | 2 | ||
Size (H x W x L) | 4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in) | ||
Weight | 340 g (12 oz) | ||
Warranty | Three years | ||
Not compatible with Fluke CNX test tools |
Modelos: Kit combinado Fluke 3000 FC/TPAK - Inclui medidor e suporte magnético
Includes:
- Fluke 3000 FC True-rms digital multimeter with backlight
- Fluke TL75 test leads
- Fluke C35 lightweight soft carrying case
- ToolPak™ magnetic meter hanger
- Installed batteries
- User's manual CD