Kit combinado Fluke 3000 FC/EDA2 - Inclui medidor e acessórios Deluxe

  • Fluke 3000 FC/EDA2 Combo Kit

Características principais

The Fluke 3000 FC has features and functions needed to troubleshoot your equipment and plant.

  • True-rms AC voltage and current for accurate measurements on non-linear loads
  • Large digit display with analog bargraph
  • Display backlight for work in dark areas
  • Capacitance
  • Records minimum and maximum values to aid in troubleshooting
  • Free your hands with the magnetic hanger included in this combo kit
  • 3 year warranty
  • Plus, the Fluke Connect wireless enabled modules measure AC, DC and AC+DC voltage, AC and DC current, plus temperature, all of which display on the Fluke 3000 FC Series Wireless Multimeter. Choose a standard clamp or flexible clamp to measure AC current. Mix and match modules to suit your unique measurement needs. Read the primary measurement on the main display and up to three modules at any one time. Modules are available separately or as part of Fluke Connect kits

Descrição do produto: Kit combinado Fluke 3000 FC/EDA2 - Inclui medidor e acessórios Deluxe

Agora compatível com o aplicativo móvel Fluke Connect®

O Multímetro Fluke 3000 Série FC coloca ferramentas de teste sem fio, não o seu corpo, próximos de quadros elétricos em funcionamento. Melhore a segurança e a eficiência usando esse testador.

Todos os registros, diretamente do campo de trabalho. O Multímetro Sem fio True-RMS Fluke 3000 FC com aplicativo Fluke Connect e chamada de vídeo ShareLive™.

Com sua precisão, confiabilidade e facilidade de uso, o Multímetro Sem fio Fluke 3000 FC é a solução ideal para técnicos profissionais. Testado independentemente para uso seguro nos ambientes CAT IV 600V/ CAT III 1.000 V, o Fluke 3000 FC tem todos os recursos que você precisa para solucionar problemas e reparar muitas falhas em sistemas elétricos e eletrônicos.

O Fluke 3000 FC fornece medições de tensão e corrente True-RMS, resolução de 6000 contagens, variação manual e automática e fornece medições de frequência, capacidade, resistência, continuidade e diodo. Além disso, o Fluke 3000 FC fornece uma precisão básica mais alta de 0,09%, um visor digital mostrando até três medições a partir dos módulos remotos, e uma iluminação de fundo totalmente branca.

Trabalhe em segurança próximo de quadros elétricos usando menos equipamentos de proteção pessoal

O Multímetro Sem fio True-RMS Fluke 3000 FC e as ferramentas de teste sem fio Fluke Connect colocam as ferramentas, e não o seu corpo, próximo de quadros elétricos em funcionamento. É simples. Apenas desenergize o gabinete, abra o quadro usando equipamento de proteção pessoal e conecte os módulos remotos, sejam módulos de tensão, pinças amperimétricas e loops de corrente flexíveis ou termômetros. Em seguida, faça a leitura dos resultados no Multímetro Sem fio 3000 FC a partir de uma distância segura. Você pode exibir a medição do medidor, além das leituras de até 3 módulos sem fio, enquanto reduz o risco de arco elétrico ao separar você de situações de medições perigosas.

Melhor ainda, o Multímetro Sem fio Fluke 3000 Série FC pode enviar dados de medição para seu smartphone, para que você possa salvar e compartilhar medições de campo com sua equipe a qualquer momento, de qualquer lugar.

Não fique em situações desagradáveis ao procurar eventos inter-relacionados

Tempo é tudo ao tentar encontrar a causa de um problema complexo. Frequentemente, você precisa fazer uma medição em um local e ver a atividade em outra parte do sistema ao mesmo tempo. Nós resolvemos esse problema com o Fluke Connect - conecte seus módulos remotos em um local e, depois, faça suas medições a até 20 metros de distância com o multímetro Fluke 3000 FC. Você poderá ver a interação entre seus pontos de ensaio remoto em uma única tela, em tempo real. Você pode até mesmo baixar os dados para um PC para fazer outras análises.

Outros recursos do Fluke Connect e do Multímetro 3000 FC.

  • Adicione seu laptop e passe de registrar para analisar e diagnosticar.
  • Faça registros ao longo do tempo usando os módulos sem fio Fluke Connect e monitore as alterações de carga do circuito por uma hora, um turno ou uma semana.
  • Use o adaptador USB sem fio Fluke Connect para coletar os dados registrados dos módulos remotos passando por um módulo em funcionamento e baixando os dados registrados.
  • Execute análises com seu PC e compartilhe os resultados usando o armazenamento Fluke Cloud™ e a chamada de vídeo ShareLive™. Visualize dados ou gráficos para obter informações de cada um dos membros da equipe.

Especificações: Kit combinado Fluke 3000 FC/EDA2 - Inclui medidor e acessórios Deluxe

AC Voltage
Range¹ / resolution 600.0 mV / 0.1 mV
6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
1000 V / 1 V
Accuracy2 3 445 Hz to 500 Hz1.0% + 3
500 Hz to 1 kHz2.0% + 3
1. AC voltage ranges are specified from 1% of range to 100% of range.
2. Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
3. For non-sinusoidial waveforms, add ± (2% of reading + 2% full scale) typical, for crest factor up to 3.
4. Do not exceed 107 V-Hz.
DC Voltage, Continuity, Resistance, Diode Test and Capacitance
mVRange / resolution600.0 mV / 0.1 mV
Accuracy0.09% + 2
VRange / resolution6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
1000 V / 1 V
Accuracy0.09% + 2
0.15% + 2
)))Range / resolution600 Ω / 1 Ω
AccuracyMeter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer.
ΩRange / resolution600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
60.00 kΩ / 0.1 kΩ
600.0 kΩ / 0.001 MΩ
50.00 MΩ / 0.01 MΩ
Accuracy0.5% + 2
0.5% + 1
1.5% + 3
Diode testRange / resolution2.000 V / 0.001 V
Accuracy1% + 2
µFRange / resolution1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF1 / 1 μF
Accuracy1.2% + 2
10% typical
1. In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2% + 2.
AC and DC Current
mA AC
(45 Hz to 1 kHz)
Range1 / resolution60.00 mA / 0.01 mA
400.0 mA3 / 0.1 mA
Accuracy1.5% + 3
mA DC2Range1 / resolution60.00 mA / 0.01 mA
400.0 mA3 / 0.1 mA
Accuracy0.5% + 3
1. All AC current ranges are specified from 5% of range to 100% of range.
2. Input burden voltage (typical): 400 mA input 2 mV/mA.
3. 400.0 mA accuracy specified up to 600 mA overload.
Frequency
Range / resolution99.99 Hz / 0.01 Hz
999.9 Hz / 0.1 Hz
9.999 kHz / 0.001 kHz
99.99 kHz / 0.01 kHz
Accuracy10.1% + 1
1. Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.
Input Characteristics
Overload protection1100 V RMS
Input impedance (nominal)> 10 MΩ < 100 pF
Common mode rejection ratio
(1 kΩ unbalance)
> 120 dB at DC, 50 Hz or 60 Hz
Normal mode rejection> 60 dB at 50 Hz or 60 Hz
Overload protection1100 V RMS
Input impedance (nominal)> 10 MΩ < 100 pF
Common mode rejection ratio
(1 kΩ unbalance)
> 60 dB, DC to 60 Hz
Normal mode rejection> 60 dB at 50 Hz or 60 Hz
Overload protection1100 V RMS
Input impedance (nominal)> 10 MΩ < 100 pF
Common mode rejection ratio
(1 kΩ unbalance)
> 120 dB at DC, 50 Hz or 60 Hz
Normal mode rejection> 60 dB at 50 Hz or 60 Hz
Open Circuit Test Voltage
Overload protection1100 V RMS
Input impedance (nominal)< 2.7 V DC
Full scale voltage to 6 MΩ
Full scale voltage 50 MΩ
< 0.7 V DC
< 0.9 V DC
Typical short circuit current< 350 mA
Overload protection1100 V RMS
Input impedance (nominal)< 2.7 V DC
Full scale voltage to 6 MΩ
Full scale voltage 50 MΩ
2.000 V DC
Typical short circuit current< 1.1 mA
mA Function
Overload protectionFused, 44/100 A, 1000 V FAST Fuse
Overload600 mA overload for 2 minutes maximum, 10 minutes rest minimum
MIN/MAX Recording Accuracy
DC functions± 12 counts for changes > 350 mS in duration.
AC functions± 40 counts for changes > 900 mS in duration.
General Specifications
Maximum voltage between any terminal and earth ground1000 V DC or AC RMS
Ω fuse protection from A inputs0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
Display (LCD)Update rate4/sec
Volts, amps, ohms6000 counts
Frequency10,000 counts
Capacitance1,000 counts
Battery typeThree AA Alkaline batteries, NEDA 15A IEC LR6
Battery life250 hours minimum
RF communications2.4 GHZ ISM Band
RF communication rangeOpen air, unobstructedUp to 20m
Obstructed, sheetrock wallUp to 6.5m
Obstructed, concrete wall, or steel electrical enclosureUp to 3.5m
TemperatureOperating-10°C to 50°C
Storage-40°C to 60°C
Temperature coefficient0.1 X (specified accuracy) / °C (< 18°C or > 28°C)
Relative humidity0% to 90% (0°C to 35°C)
0% to 75% (35°C to 40°C)
0% to 45% (40°C to 50°C)
AltitudeOperating2,000 m
Storage12,000 m
Electromagnetic compatibility
EMI, RFI, EMC, RF
EN 61326–1:2006, EN 61326–2–2:2006
ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
V1.8.1:2008
FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
FCCID : FCC: T68–FDMMBLE IC: 6627A–FDMMBLE
Safety complianceANSI / ISA 61010–1 / (82.02.01): 3rd edition
CAN / CSA-C22.2 No 61010-1-12: 3rd edition
UL 61010–1: 3rd edition
IEC / EN 61010–1:2010
CertificationsCSA, FCC, CE
Ingress Protection (IP) ratingIP54
Pollution Degree2
Size (H x W x L)4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in)
Weight340 g (12 oz)
WarrantyThree years
Not compatible with Fluke CNX test tools

Modelos: Kit combinado Fluke 3000 FC/EDA2 - Inclui medidor e acessórios Deluxe

FLK-3000 FC/EDA2
Fluke 3000 FC/EDA2 Combo Kit

Compre

Includes:

  • Fluke 3000 FC True-rms digital multimeter with backlight
  • Fluke TL910 electronic test probes
  • Fluke TL224 silicone test leads
  • Fluke AC280 heavy duty hook clips
  • Fluke C35 lightweight soft carrying case
  • ToolPak™ magnetic meter hanger
  • Installed batteries
  • User's manual CD