Multímetro Digital Fluke 113

  • Fluke 113 Digital Multimeter
  • Fluke 113 Digital Multimeter
  • Fluke 113 Digital Multimeter
  • Video Player is loading.
    Current Time 0:00
    Duration 0:42
    Loaded: 0%
    Stream Type LIVE
    Remaining Time 0:42
     
    1x
      • Chapters
      • descriptions off, selected
      • subtitles off, selected
      • en (Main), selected
    1. Fluke 113 Digital Multimeter
    2. Fluke 113 Digital Multimeter
    3. Fluke 113 Digital Multimeter
    4. How to choose the right multimeter

    Características principais

    Ler mais

    Descrição do produto: Multímetro Digital Fluke 113

    O multímetro digital Fluke 113 fornece aos utilizadores um meio para efetuar, de forma rápida e fácil, testes básicos de medição e ligação. Este medidor é fácil de utilizar e inclui as funções necessárias para reparar a maior parte dos problemas elétricos. O Fluke 113 apresenta melhorias significativas relativamente a outros multímetros digitais disponíveis no mercado, incluindo o modelo 7-600 da Fluke. Utilizando a função de medição de impedância baixa VCHEK™ LoZ da Fluke, os utilizadores conseguem testar tensão ou continuidade em simultâneo. As medições de impedância baixa LoZ também bloqueiam tensões fantasma induzidas por condutores próximos. *Tenha em atenção que as medições de impedância baixa LoZ apresentam uma carga baixa num circuito protegido por um RCD, o que pode provocar o disparo do RCD. A função Mín./Máx. permite-lhe registar as flutuações de sinal. O Fluke 113 permite efetuar testes de díodo e também inclui capacidades de seleção automática e manual de intervalos. Com caraterísticas como conformidade com as normas de segurança mais recentes, retroiluminação e um display de dimensões muito superiores para uma visualização mais fácil, este medidor é essencial em todas as caixas de ferramentas.

    Especificações: Multímetro Digital Fluke 113

    Specifications
    VCHEK1 2 3Range6.000 V / 60.00 V / 600.0 V
    Resolution0.001 V / 0.01 V/ 0.1 V
    AccuracyDC, 45 to 500 Hz: 2.0% + 3
    500 Hz to 1 kHz: 4.0% + 3
    Diode test4Range2.000 V
    Resolution0.001 V
    Accuracy2.0% + 3
    Continuity4AccuracyBeeper on < 20 Ω, off > 250 Ω detects opens or shorts of 500 μs or longer
    Ω4Range600.0 Ω / 6.000 kΩ / 60.00 kΩ
    Resolution0.1 Ω / 0.001 kΩ / 0.01 kΩ
    Accuracy0.9% + 2 / 0.9% + 1 / 0.9% + 1
    Capacitance4Range1000 nF / 10.00 μF / 100.0 μF / 9999 μF
    Resolution1 nF / 0.01 μF / 0.1 μF / 1 μF
    Accuracy1.9% + 2
    100 μF - 1000 μF: 1.9% + 2
    1000 μF: 5% + 20
    1. All VChek voltage ranges are specified from 60 counts to 100% of range. Because inputs below 60 counts are not specified, it is possible and normal for this and other true-rms meters to display non-zero readings when the test leads are disconnected from a circuit or are shorted together.
    2. Crest factor of ≤ 3 at 4000 counts, decreasing linearly to 1.5 at full scale.
    3. Minimum measureable input in VCHEK autorange is 3 VDC. For measurements below 3 VDC, push Range button twice to get to 6 VDC manual range.
    4. After measuring voltage, a wait time of 1 minute is required to maintain accuracy of ohms, capacitance, diode test, and continuity.
    Specifications
    Maximum voltage between any terminal and earth ground600 V
    Display3 3/4-digits, 6000 counts, updates 4/sec
    Operating temperature-10°C to 50°C (14°F to 122°F)
    Storage temperature-40°C to 60°C (-22°F to 140°F)
    Temperature coefficient0.1 x (specified accuracy) / °C (< 18°C or > 28°C)
    Operating altitude2,000 m
    Storage altitude10,000 m
    Relative humidity95% to 30°C
    75% to 40°C
    45% to 50°C
    Battery type9 Volt Alkaline, IEC 6F22
    Battery lifeAlkaline: 300 hours typical, without backlight
    Size (H x W x L)167.1 x 85.1 x 46.0 mm (6.58 x 3.35 x 1.81 in)
    Weight13.0 oz (404 g)
    SafetyIEC 61010-1: Pollution Degree 2
    IEC 61010-2-033: CAT IV 600V
    EMI regulationsComplies with FCC Part 15, Class B
    Specifications
    VCHEKInput impedance (nominal)~3 kΩ < 300 pF
    VCHEKCommon mode rejection ratio
    (1 kΩ unbalanced)
    > 60 dB at DC, 50 or 60 Hz
    ΩOpen circuit test voltage< 2.7 VDC
    Full scale voltage< 0.7 VDC
    Diode testOpen circuit test voltage2.7 VDC
    Full scale voltage2.000 VDC
    ΩShort circuit current< 350 μA
    Diode testShort circuit current< 1.0 mA

    Modelos: Multímetro Digital Fluke 113

    Fluke 113
    Fluke 113 Digital Multimeter

    Compre

    Includes:

    • Fluke TL75 test leads
    • Holster
    • Users manual
    • and 9 V battery (installed)