Multimetro digitale Fluke 283 FC CAT III 1500V

  • Fluke 283 FC 1500 V DC Digital Multimeter
  • Fluke 283 FC Digital Multimeter with TL175-HV Test Leads
  • Fluke 283 FC Multimeter Readiness Self-Check
  • Fluke 283 FC CAT III 1500 V Rated Digital Multimter
  • Video Player is loading.
    Current Time 0:00
    Duration 0:00
    Loaded: 0%
    Stream Type LIVE
    Remaining Time 0:00
     
    1x
      • Chapters
      • descriptions off, selected
      • subtitles off, selected
      1. Fluke 283 FC 1500 V DC Digital Multimeter
      2. Fluke 283 FC Digital Multimeter with TL175-HV Test Leads
      3. Fluke 283 FC Multimeter Readiness Self-Check
      4. Fluke 283 FC CAT III 1500 V Rated Digital Multimter
      5. 283 FC 1500 V Digital Multimeter Overview Video

      Caratteristiche principali

      Maggiori informazioni

      Descrizione generale del prodotto: Multimetro digitale Fluke 283 FC CAT III 1500V

      Il multimetro digitale Fluke 283 FC True-RMS CAT III 1500 V/CAT IV 1000 V stabilisce il nuovo standard per i tecnici che lavorano in ambienti in CC fino a 1500 V. Che si tratti di un array fotovoltaico (FV) su scala industriale, di energia eolica, di ferrovie elettriche o di un data center, il Fluke 283 FC è stato progettato per migliorare la sicurezza e aumentare la produttività, offrendo risultati accurati, affidabili e ripetibili.

      Il 283 FC include i puntali TL175-HV Insert TwistGuard™️in silicone con classe di sicurezza CAT III 1500 V/CAT IV 1000 V, che permettono di lavorare senza problemi in ambienti a tensioni più elevate senza compromettere la sicurezza, offrendo maggiore flessibilità durante i test di tensione, millivolt, resistenza, continuità o capacità. Il luminoso schermo LCD retroilluminato e la tastiera illuminata ne facilitano l’uso in condizioni di luce diretta o scarsa. Il kit di aggancio magnetico incluso consente di tenere le mani libere durante l’uso mentre la resistente custodia aiuta a proteggere il tuo investimento durante il trasporto.

      Funzioni aggiuntive:

      • Misurazioni di tensione altamente accurate per una ricerca guasti precisa in prima linea
      • Misurazioni di corrente fino a 60 A CA/CC per la ricerca guasti sicura di singole stringhe di moduli con maggiore precisione (quando si utilizza una pinza amperometrica wireless a283 FC opzionale)
      • Gli indicatori di polarità visiva e audio con funzione on/off aiutano a prevenire i problemi di cablaggio
      • L’indicatore di limite definito dall’utente aiuta a prendere decisioni rapide di ricerca guasti go/no-go
      • L’esclusiva funzione di autoverifica della funzionalità del multimetro aiuta a garantire che il misuratore sia pronto per il test
      • Salva e registra le misurazioni nella memoria interna e visualizzale sul dispositivo mobile tramite Fluke Connect™

      In dotazione:

      • Multimetro digitale wireless 283 FC TRMS
      • Puntali in silicone TL175-HV TwistGuard™
      • Custodia da trasporto Premium
      • Cinghia con aggancio magnetico
      • Garanzia a vita limitata

      Dati tecnici: Multimetro digitale Fluke 283 FC CAT III 1500V

      FunzioneRangeRisoluzionePrecisione
      Volt c.a.[1]6,000 V0,001 V1,0% + 3
      (da 45 Hz a 500 Hz)
      60,00 V0,01 V
      600,0 V0,1 V2,0% + 3
      (da 500 Hz a 1 kHz)
      1000 V1 V
      Volt c.c.6,000 V0,001 V0,09% + 3
      60,00 V0,01 V
      600,0 V0,1 V
      1500 V1 V0,15% + 2
      mV c.a.[1]600,0 mV0,1 mV1,0% + 3 (45 Hz ~ 500 Hz)
      2,0% + 3 (500 Hz ~ 1000 Hz)
      mV c.c.600,0 mV0,1 mV0,09% + 2
      Continuità600 Ω1 Ω 
      Resistenza600,0 Ω0,1 Ω0,5% + 4
      6,000 kΩ0,001 kΩ
      60,00 kΩ0,01 kΩ
      600,0 kΩ0,1 kΩ
      6,000 MΩ0,001 MΩ
      50,00 MΩ0,01 MΩ1,5% + 4
      Capacità1000 nF1 nF1,2% + 2
      10,00 μF0,01 μF
      100,0 μF0,1 μF
      9999 μF1 μF10% tipica
      Frequenza99,99 Hz0,01 Hz0,1% + 2
      999,9 Hz0,1 Hz
      9,999 kHz0,001 kHz
      99,99 kHz0,01 kHz
      VA c.c. (45 Hz ~ 500 Hz)[1]360,0 VA0,1 VA2% + 1,0 VA
      3,600 kVA0,001 kVA2% + 0,01 kVA
      36,00 kVA0,01 kVA2% + 0,1 kVA
      60,00 kVA0,01 kVA2% + 0,15 kVA
      VA c.c.[1]360,0 VA0,1 VA2% + 1,0 VA
      3,600 kVA0,001 kVA2% + 0,01 kVA
      36,00 kVA0,01 kVA2% + 0,1 kVA
      90,00 kVA0,01 kVA2% + 0,25 kVA
      Min-Max-MediaPer le funzioni in CC, la precisione è l'accuratezza specificata della funzione di misurazione ± 12 punti per variazioni di durata maggiori di 350 ms.
      Per le funzioni in CA, la precisione è l'accuratezza specificata della funzione di misurazione ± 40 punti per variazioni di durata maggiori di 900 ms.

      [1] <1% della gamma, non specificato

      Specifiche ambientali
      Temperatura di esercizioDa -10 °C a 60 °C
      Temperatura di stoccaggioDa -30 °C a +70 °C
      Umidità (senza condensa)Da 0% a 90%, da 10 °C a 30 °C
      Da 0% a 75%, da 30 °C a 40 °C
      Da 0% a 45%, da 40 °C a 60 °C
      Garanzia e protezione
      Compatibilità elettromagneticaIEC 61326-1, IEC 61326-2-2, portatile, gruppo 1, classe A
      Categoria di sovratensioneCAT III 1500 V, CAT IV 1000 V
      Omologazioni di entiETL (AMER ed EMEA), CSA (APAC), CE, UK CA
      Test di cadutaTestato per cadute da 2 metri
      Grado di protezioneIP52
      GaranziaDurata limitata
      Specifiche generali e meccaniche
      Conteggi6000
      Dimensioni22,5 cm x 10,5 cm x 5,7 cm
      Peso0,7 kg
      Autonomia delle batterie> 150 ore (uso tipico), senza retroilluminazione (3 batterie alcaline AA)
      > 100 ore (uso tipico) se collegato a una pinza amperometrica wireless (3 batterie alcaline AA)