Fluke T5-600 and 62 MAX+ Electrical and HVAC Kit
Caratteristiche principali
- Automatically measures volts ac and volts dc with precise digital resolution.
- Displays resistance to 1000?.
- Easy and accurate OpenJaw™ current measurement.
- Continuity beeper.
- Rugged enough to withstand a 10-foot (3m) drop.
- 600V model.
- Auto off mode to conserve battery life.
- AC current.
- Display hold.
- All inputs of the T5-600 are protected to EN61010-1 CAT III 600V. UL, CSA and VDE listed.
Fluke 62 MAX+. Small in size. Big on toughness.
- Dust and water-resistant: IP54 rated.
- Rugged: 3-meter (9.8-foot) drop tested.
- Ergonomically designed: Completely redesigned for a more natural hand fit.
- Distance to spot: 12:1.
- Dual lasers: Identifies area to be measured.
- Large, backlit display: Makes data easier to read, even in dark areas.
- C115 Deluxe Soft Carrying Case with Shoulder Strap.
Descrizione generale del prodotto: Fluke T5-600 and 62 MAX+ Electrical and HVAC Kit
This kit is designed to help electricians and HVAC technicians solve problems quicker. Test first for overheated electrical devices using an IR thermometer; then use electrical test tools to find out more about the problem.
Dati tecnici: Fluke T5-600 and 62 MAX+ Electrical and HVAC Kit
Fluke T5-600 Voltage, Continuity and Current Tester
Specifications | ||
Jaw opening | 12.9 mm (0.5 in) | |
Max wire size | 1/0 THHN Cable | |
Current range AC rms | 0 to 100.0 A | |
Accuracy AC current (50/60 Hz) | 3% ± 3 counts | |
AC response | Averaging | |
Voltage range AC/DC | 0 to 600 V | |
Voltage accuracy | AC | 1.5% ± 2 counts |
DC | 1% ± 1 count | |
Resistance range | 0 to 1000 Ω | |
Continuity beeper threshold | On at < 25 Ω, off at > 400 Ω | |
Volts indicator LED threshold | Guaranteed on by 30 V AC | |
Environmental specifications | ||
Operating temperature | -10°C to 50°C | |
Storage temperature | -30°C to 60°C | |
Humidity (without condensation) | 0% to 95% (5°C to 30°C) | |
0% to 75% (30°C to 40°C) | ||
0% to 45% (40°C to 50°C) | ||
Dust/water resistance | Yes | |
Operating altitude | 2000 meters max | |
Temperature coefficient | 0.1 x (specified accuracy)/°C (< 18°C or > 28°C) | |
Safety Specifications | ||
Overvoltage category | CAT III 600 V AC/DC (EN61010-1) | |
Agency approvals | UL, CSA, and VDE | |
Maximum voltage | Between any terminal and earth ground | |
Mechanical and general specifications | ||
Size | 30.5 x 51 x 203 mm | |
Weight | 300 g | |
Warranty | Two-years | |
Battery life | 200 hour zinc chloride, 400 hour alkaline | |
Battery type | 2 x AA | |
Low battery indicator | Yes | |
Current sensor opening | 12.9 mm | |
Calibration cycle | 1 year | |
Test leads | Type | Heavy duty, flexible leads rated for 1000 V use. |
Field replaceable leads terminate in male shrouded banana plugs | ||
Probes | One red, one black. | |
Detachable Slim-Reach™ probe tips | ||
Styles | TP1 Slim Reach™ Test Probes |
Fluke 62 MAX+ Infrared Thermometer
Specifications | ||
Temperature range | -30°C to 650°C (-22°F to 1202°F) | |
Accuracy | ±1.0°C or ±1.0% of reading, whichever is greater -10°C to 0°C: ±2.0 -30°C to -10°C: ±3.0 | |
Response time (95%) | < 500 ms (95% of reading) | |
Spectral response | 8 to 14 microns | |
Emissivity | 0.10 to 1.00 | |
Optical resolution | 12:1 (calculated at 90% energy) | |
Display resolution | 0.1°C (0.2°F) | |
Repeatability of readings | ±0.5% of reading or <±0.5°C (1°F), whichever is greater | |
Power | AA battery | |
Battery life | 8 hours with laser and backlight on | |
Physical specifications | ||
Weight | 255 g (8.99 oz) | |
Size | 175 x 85 x 75 mm (6.88 x 3.34 x 2.95 in) | |
Operating temperature | 0°C to 50°C (32°F to 122°F) | |
Storage temperature | -20°C to 60°C (-4°F to 140°F), (without battery) | |
Operating humidity | 10% to 90% RH non-condensing at 30°C (86°F) | |
Operating altitude | 2000 meters above mean sea level | |
Storage altitude | 12,000 meters above mean sea level | |
IP rating | IP 54 per IEC 60529 | |
Drop test | 3 meters | |
Vibration and shock | IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms | |
EMC | EN 61326-1:2006 EN 61326-2:2006 | |
Standards and agency approval | Compliance | EN/IEC 61010-1: 2001 |
Laser safety | FDA and EN 60825-1 Class II |