Fluke 87V MAX True-rms Digital Multimeter
Compare products: digital multimeter
- Fluke 87V Industrial Multimeter
- Fluke 179 True-RMS Digital Multimeter
- Fluke 117 Electrician's Ideal Multimeter with Non-Contact Voltage
- Fluke 115 Field Service Technicians Multimeter
- Fluke 177 True-RMS Digital Multimeter
- Fluke 289 True-RMS Data Logging Multimeter
- Fluke 28 II Rugged Digital Multimeter
- Fluke 116 HVAC Multimeter with Temperature and Microamps
- Fluke 287 True-rms Electronics Logging Multimeter with TrendCapture
- Electricians’s Multimeter: Fluke 114 Electrical Multimeter
- Digital Multimeters: Fluke 113 Utility Multimeter
- Fluke 233 Remote Display Multimeter
- Fluke 80 Series V Digital Multimeters: The Industrial Standard
- Fluke 28 II Ex Intrinsically Safe True-rms Digital Multimeter
- Fluke 175 True-RMS Digital Multimeter
- Fluke 27 II Rugged Digital Multimeter
- Fluke 88V Deluxe Automotive Multimeter
- Fluke 77 IV Series Digital Multimeter
- Multimeter Digital Fluke 107 Seukuran Genggaman
Fitur utama
- Tahan jatuh dari ketinggian hingga 4 meter (13 kaki) dengan casing dan sarung berkekuatan tingkat industri
- Casing luar kedap air dan tahan debu berperingkat IP67 untuk lokasi kerja paling ekstrem
- Test lead TL175 TwistGuard™ premium
- Masa pakai baterai dua kali dibandingkan 87V (hingga 800 jam); tombol berlampu latar untuk lingkungan gelap
Ikhtisar Produk: Fluke 87V MAX True-rms Digital Multimeter
87V MAX berisi semua fitur tepercaya dari DMM paling populer yang digunakan saat ini, Fluke 87V, dengan masih banyak tambahan lainnya.
Tahan jatuh dari ketinggian hingga 4 meter (13 kaki)
Multimeter digital paling kokoh dari Fluke. 87V MAX dilengkapi dengan casing yang kokoh untuk pemakaian industri dan sarung yang dapat dilepas. Sarung ini juga berfungsi sebagai penahan probe uji untuk operasi satu tangan.
Berperingkat IP67
Benar-benar kedap air dan tahan debu, agar bekerja andal di semua tempat Anda perlu bekerja.
Tahan panas dan dingin
Alat ukur ini memiliki rentang temperatur operasi yang lebih panjang dari -40 °C (untuk hingga 20 menit) hingga +55 °C.
Sorotan produk lainnya
- Arus dan tegangan ac true-rms untuk pengukuran yang akurat pada sinyal non-linier
- Mengukur hingga 1000 V ac dan dc
- Mengukur hingga 10 A (20 A selama 30 detik)
- Frekuensi hingga 200 kHz
- Termometer bawaan memungkinkan Anda dengan leluasa memanfaatkan pembacaan suhu tanpa harus membawa instrumen terpisah
- Perekaman Min/Maks/Rata-rata, plus 250 μs Puncak min-maks untuk merekam variasi secara otomatis
- Fungsi unik untuk pengukuran tegangan dan frekuensi yang akurat pada penggerak motor frekuensi variabel dan peralatan bising secara elektrik lainnya
- Tampilan digit besar, 2 tingkat kecerahan, lampu latar putih, dan tombol keypad berpencahayaan belakang untuk visibilitas yang lebih baik
- Layar mode angka 19.999 resolusi tinggi
- Masa pakai baterai yang tahan lama (800 jam)
Perbandingan – 87V MAX dan 87V
87V MAX | 87 V | |
---|---|---|
Rating IP | IP 67 | IP 30 |
Daya tahan baterai | 800 jam | 400 jam |
Tes jatuh | 4 meter | 3 meter |
Keypad berlampu latar | Ya | Tidak |
Test lead TwistGuard™ | Ya | Tidak |
Nilai True-rms | ac | ac |
Akurasi dc dasar | 0,05% | 0,05% |
Tegangan ac/dc | 1000 V | 1000 V |
Arus ac/dc | 10 A | 10 A |
Hambatan | 50 MΩ | 50 MΩ |
EN61010-1 CAT III | 1000 V | 1000 V |
EN61010-1 CAT IV | 600 V | 600 V |
Garansi (tahun) | Terbatas seumur hidup | Terbatas seumur hidup |
Spesifikasi: Fluke 87V MAX True-rms Digital Multimeter
Spesifikasi Kelistrikan | ||
Tegangan DC | Rentang | 0,1 mV sampai 1000 V |
Akurasi | ±(0,05% + 1) | |
Resolusi maksimum | 0,1 mV | |
Tegangan AC | Rentang | 0,1 mV sampai 1000 V |
Akurasi | ±(0,7% + 4) true-rms | |
Bandwidth AC | 20 kHz dengan low pass filter; 3 dB @ 1 kHz | |
Resolusi maksimum | 0,1 mV | |
Arus DC | Rentang | 0,1 μA s/d 10 A (20 A selama maksimum 30 detik) |
Akurasi Amps | ±(0,2% + 2) | |
Resolusi maksimum | 0,1 µA | |
Arus AC | Rentang | 0,1 μA s/d 10 A (20 A selama maksimum 30 detik) |
Akurasi Amps | ±(1,0% + 2) true-rms | |
Resolusi maksimum | 0,1 µA | |
Hambatan | Rentang | 0,1 Ω s/d 50 MΩ |
Akurasi | ±(0,2% + 1) | |
Resolusi maksimum | 0,1 Ω | |
Kapasitansi | Rentang | 0,01 nF hingga 9999 μF |
Akurasi | ±(1% + 2) | |
Resolusi maksimum | 0,01 nF | |
Frekuensi | Rentang | 0,5 Hz hingga 199,99 kHz |
Akurasi | ±(0,005% + 1) | |
Resolusi maksimum | 0,01 Hz | |
Siklus kerja | Siklus kerja maksimum | 99,9% |
Akurasi | ±(0,2% per kHz + 0,1%) | |
Resolusi maksimum | 0,1% | |
Rentang pengukuran suhu | –200,0 °C s/d 1090 °C –328,0 °F s/d 1994,0 °F tidak termasuk pemindai | |
Pemindai suhu 80 BK | –40,0 °C s/d 260 °C, ± 2,2 °C atau 2% mana yang lebih besar –40,0 °F s/d 500 °F, ± 4,0 °F atau 2% mana yang lebih besar | |
Konduktansi | Konduktansi maksimum | 60,00 nS |
Akurasi | ±(1,0% + 10) | |
Resolusi maksimum | 0,01 nS | |
Tes diode | Rentang | 2 V |
Resolusi | 0,001V | |
Akurasi | ±(1% + 1) | |
Penyimpanan diagnostik dan data | Min/Maks Puncak | 250 μS |
Min/Max/Avg | Ya | |
Tahan pembacaan/Tahan (Sentuh) otomatis | Ya | |
Referensi relatif | Ya | |
Layar | Digital | 6000 hitungan update 4/detik 19.999 hitungan dalam mode resolusi tinggi |
Grafik batang analog | 32 segmen, update 40/detik | |
Lampu latar | Dua tingkat | |
Low pass filter (pengukuran VFD) | Ya | |
Input Alert™ | Ya | |
Spesifikasi Keselamatan | ||
Rating keselamatan | IEC61010-1: Tingkat Polusi 2 IEC 61010-2-033: CAT IV 600 V / CAT III 1000 V | |
Persetujuan agen | CE, CSA | |
Spesifikasi Mekanis dan Umum | ||
IP rating | IEC 60529: IP67 | |
Daya | Tiga baterai AA. 800 jam penggunaan biasa tanpa lampu latar | |
Ukuran | 6,0 x 10,1 x 21,5 cm (dengan sarung) | |
Berat | 698,5 g (dengan sarung) | |
Garansi | Terbatas seumur hidup | |
Spesifikasi Lingkungan | ||
Suhu pengoperasian | -15 °C s/d 55 °C, s/d -40 °C selama 20 menit saat diambil dari 20 °C | |
Suhu penyimpanan | -40 °C to + 60 °C | |
Kelembapan (tanpa kondensasi) | 0% – 90% (0 °C – 35 °C) 0% – 70% (35 °C – 55 °C) | |
Ketinggian pengoperasian | 2000 m |
Model: Fluke 87V MAX True-rms Digital Multimeter
Fluke 87V MAX
Fluke 87V MAX True-rms Digital Multimeter
Mencakup:
- Test lead TL175 TwistGuard™
- Alligator clip AC175
- Pemindai temperatur 80BK-A
- Sarung dapat dilepas dengan penyimpanan kabel pengujian
- Tiga baterai AA (terpasang)