Starter kit Fluke 117 Multimeter Teknisi Listrik plus starter kit insulated hand tools

  • F-117 Multimeter plus insulated hand tools starter kit
  • Heavy duty, high leverage diagonal cutter with power joint and precision cutting edges. 1000 V ac rated.
  • Fluke 117 Electrician's Multimeter
  • Video Player is loading.
    Current Time 0:00
    Duration 0:59
    Loaded: 0%
    Stream Type LIVE
    Remaining Time 0:59
     
    1x
      • Chapters
      • descriptions off, selected
      • en (Main), selected
    • Video Player is loading.
      Current Time 0:00
      Duration 0:49
      Loaded: 0%
      Stream Type LIVE
      Remaining Time 0:49
       
      1x
        • Chapters
        • descriptions off, selected
        • en (Main), selected
      1. F-117 Multimeter plus insulated hand tools starter kit
      2. Heavy duty, high leverage diagonal cutter with power joint and precision cutting edges. 1000 V ac rated.
      3. Fluke 117 Electrician's Multimeter
      4. Fluke Insulated Hand Tools
      5. Fluke Pro Tips - Insulated Hand Tools

      Fitur utama

      • Fluke 117 Multimeter Teknisi Listrik
      • 3 slotted insulated screwdrivers
      • 2 Phillips insulated screwdrivers
      • 3 insulated pliers
      • Kantong alat gulung

      Ikhtisar Produk: Starter kit Fluke 117 Multimeter Teknisi Listrik plus starter kit insulated hand tools

      Fluke 117 Multimeter Teknisi Listrik kombinasi dengan starter kit insulated hand tools, berisi obeng, tang, dan pemotong yang paling sering digunakan.

      Fluke 117 Digital Multimeter adalah meteran true-rms dengan deteksi tegangan non-kontak terintegrasi untuk membantu menyelesaikan pekerjaan lebih cepat. Dengan fungsi Auto Volts dan LoZ yang membantu mencegah pembacaan yang salah yang disebabkan oleh ghost voltage, Fluke 117 adalah pilihan tepat bagi teknisi listrik. Fluke 117 memberikan pembacaan Min / Max / Average, mengukur frekuensi dan kapasitansi.

      Starter kit insulated hand tools memiliki tiga ukuran slot screwdrivers. #1 and #2 Phillips screwdrivers. Long nose pliers, pemotong diagonal kuat, dan tang kombinasi lineman kuat. Semua terbuat dari baja chromium-molybdenum-vanadium (CMV). Semua tersertifikasi untuk 1000 volts AC and 1500V DC. Semua dengangaransi seumur hidup terbatas.

      Fluke 117 Multimeter Teknisi Listrik

      • Multimeter akurat dan mudah digunakan dengan teknologi VoltAlert ™ terintegrasi untuk deteksi tegangan non-kontak
      • Pemilihan voltase AC / DC otomatis AutoVolt
      • Input impedance rendah untuk membantu mencegah kesalahan pembacaan akibat ghost voltage
      • Menghadirkan lampu latar LED putih besar bekerja di tempat yang tidak menyala dengan baik.
      • Fitur True RMS untuk pengukuran akurat pada beban non linier

      Slotted screwdrivers

      • Tiga bentuk blade berbeda
      • Tiga panjang gagang

      Phillips screwdrivers

      • Tips #1 and #2
      • Dua panjang gagang

      Long nose pliers dengan pemotong samping dan cengkeraman

      • Bentuk gelombang cengkraman yang unik
      • 4 poin pegangan untuk menarik benda bulat dengan pegangan superior yang tidak akan tergelincir
      • Rahang lurus, setengah bundar, panjang dan ramping, diprofilkan secara khusus
      • Sisi cutting edge untuk memotong kawat

      Kuat, pemotong diagonal dengan leverage tinggi

      • Memotong bahan keras termasuk kawat baja dan piano
      • Kekuatan dan keakuratan pemotongan sisi ujung

      Heavy Duty Combination Pliers

      • Pegangan yang aman dengan rahang tajam yang memotong sisi secara agresif dan 4 titik lubang cengkeraman
      • Bentuk ramping untuk akses yang lebih baik ke kabel di ruang sempit
      • Cengkraman rahang yang kuat, namun beratnya 20% lebih ringan dari desain lainnya

      Spesifikasi: Starter kit Fluke 117 Multimeter Teknisi Listrik plus starter kit insulated hand tools

      Spesifikasi Fluke 117 Multimeter Teknisi Listrik

      Tegangan maksimum antara setiap terminal dan earth ground600 V
      Perlindungan sentakanPuncak 6kV per IEC61010 1 600 VCAT III Tingkat Polusi 2
      Sekering untuk masukan ASekering FAST 11 A 1.000V (Fluke PN 803293)
      TampilanDigital: 6.000 hitungan, update 4 per detik
      Grafik batang33 segmen memperbarui 32 per detik
      Suhu pengoperasian-10°C hingga +50°C
      Suhu penyimpanan-40°C hingga +60°C
      Jenis BateraiAlkaline 9 volt NEDA 1604A / IEC6LR61
      Daya tahan baterai400 jam penggunaan biasa tanpa backlight
      Spesifikasi Akurasi
      Milivolt DCRentang/resolusi600,0 mV / 0,1 mV
      Akurasi± ( [ % Pembacaan ] + [ Hitungan ] ) 0,5% + 2
      Volt DCRentang/resolusi
       
      Akurasi± ( [ % Pembacaan ] + [ Hitungan ] ) 0,5% + 2
      Volt otomatisRentang/resolusi600,0 V / 0,1 V
      Akurasi2.0% + 3 (DC, 45 Hz to 500 Hz)
      4.0% + 3 (500 Hz to 1 kHz)
      AC millivolts¹ True RMSRentang/resolusi600,0 mV / 0,1 mV
      Akurasi1.0% + 3 (DC, 45 Hz to 500 Hz)
      2.0% + 3 (500 Hz to 1 kHz)
      AC volts¹ True RMSRentang/resolusi6.000 V / 0.001 V
      60.00 V / 0.01 V
      600.0 V / 0.1 V
      Akurasi1.0% + 3 (DC, 45 Hz to 500 Hz)
      2.0% + 3 (500 Hz to 1 kHz)
      KontinuitasRentang/resolusi600 Ω / 1 Ω
      AkurasiBunyi menyala< 20 Ω, off >250 Ω mendeteksi pembukaan atau pemendek 500 μs atau lebih
      OhmRentang/resolusi600.0 Ω / 0.1 Ω
      6.000 kΩ / 0.001 kΩ
      60.00 kΩ / 0.01 kΩ
      600.0 kΩ / 0.1 kΩ
      6.000 MΩ / 0.001 MΩ
      Akurasi0,9% + 1
      Rentang/resolusi40,00 MΩ / 0,01 MΩ
      Akurasi5% + 2
      Tes diodeRentang/resolusi2,00 V / 0,001 V
      Akurasi0,9% + 2
      KapasitansiRentang/resolusi1000 nF / 1 nF
      10.00 μF / 0.01 μF
      100.0 μF / 0.1 μF
      9999 μF / 1 μF
      100 μF hingga 1000 μF
      Akurasi1.9% + 2
      Rentang/resolusi> 1000 μF
      Akurasi5% + 20%
      Kapasitansi Lo-ZRentang1 nF hingga 500 μF
      Akurasi10% + 2 typical
      AC amps True RMS (45 Hz to 500 Hz)Rentang/resolusi6.000 A / 0.001 A
      10.00 A / 0.01 A
      Akurasi1,5% + 3
      20 Kelebihan beban berkelanjutan selama maks 30 detik
      DC ampsRentang/resolusi6.000 A / 0.001 A
      10.00 A / 0.01 A
      Akurasi1,0% + 3
      20 Kelebihan beban berkelanjutan selama maks 30 detik
      Hz (input V atau A)2Rentang/resolusi99.99 Hz / 0.01 Hz
      999.99 Hz / 0.1 Hz
      9.999 Hz / 0.001 Hz
      50.00 Hz / 0.01 Hz
      Akurasi0.1% + 2
      1. Semua rentang tegangan AC kecuali Auto-V / LoZ ditentukan dari jangkauan1% hingga 100%. Auto-V / LoZ ditentukan dari 0,0 V.
      2. Ketidakpastian suhu (akurasi) tidak termasuk kesalahan probe termokopel.
      3. Frekuensi adalah gabungan AC, 5 Hz s/d 50 kHz untuk tegangan AC. Frekuensi adalah gabungan DC, 45 Hz s/d 5 kHz untuk arus AC.
      4. Rentang Suhu / Resolusi: -40°F to 752°F / 0.2°F.
      Spesifikasi Mekanis dan Umum
      Ukuran167 x 84 x 46 mm (6,57 x 3,31 x 1,82 in)
      Berat550 g
      Garansi3 tahun
      Tipe ScrewdriverPanjang blade
      (inci
      mm)
      Panjang pegangan
      (inci
      mm)
      Lebar pegangan
      (inci
      mm)
      Diameter bladeform
      (inci
      mm)
      Slot KepalaSlot3
      75
      3-3/8
      86
      1
      25
      3/32
      2.55
      Slot KepalaSlot4
      100
      3-11/16
      94
      1 5/16
      30
      5/32
      4.0
      Slot KepalaSlot5
      125
      4-3/16
      106
      1 7/16
      36
      1/4
      6.0
      Head PhillipsPhillips #13
      80
      3-11/16
      94
      1 3/16
      30
      7/32
      5
      Head PhillipsPhillips #24
      100
      4-3/16
      106
      1 7/16
      36
      1/4
      6
      Tipe PliersPanjang Nominal (inci)Panjang Nominal (mm)
      Long Nose8200
      Pemotong Diagonal8200
      Lineman Combination Pliers8200
       

      Garansi

      Garansi Seumur Hidup Fluke Insulated Hand Tool

      Setiap Fluke Insulated Hand Tool akan bebas dari cacat material dan pengerjaan seumur hidup. Seperti yang digunakan di sini, "seumur hidup" didefinisikan sebagai tujuh tahun setelah Fluke menghentikan pembuatan produk, tetapi masa garansi harus setidaknya lima belas tahun sejak tanggal pembelian. Garansi ini tidak mencakup kerusakan akibat kelalaian, penyalahgunaan, kontaminasi, perubahan, kecelakaan atau kondisi operasi atau penanganan yang tidak normal, kerusakan atau keausan normal komponen mekanis. Garansi ini hanya mencakup pembeli asli dan tidak dapat ditransfer.

      Rekomendasi untuk penggunaan dan perawatan in-service dari Fluke Insulated Hand Tools

      Berikut ini adalah panduan mengenai perawatan, inspeksi, pengujian ulang dan penggunaan Fluke Insulated Hand Tools.

      Peringatan - untuk menghindari sengatan listrik atau cedera pribadi:

      • Pastikan jari di belakang alat pelindung jari. Jangan pernah menyentuh bagian konduktif.
      • Selalu pakai pelindung mata yang disetujui.
      • Jangan gunakan di lokasi basah atau lembab. Jangan gunakan kecuali alat ini bersih dan kering.
      • Jangan berikan tekanan atau tekanan berlebihan pada alat isolasi yang dapat menyebabkan kerusakan. Contohnya termasuk menggunakan permukaan berinsulasi sebagai titik tumpu untuk mencungkil atau menggigit atau mencengkeram pegangan alat yang terisolasi dengan alat lain seperti tang atau kunci pas untuk meningkatkan torsi atau daya ungkit.

      Jika alat digunakan dengan cara yang tidak ditentukan, perlindungan mungkin terganggu.

      Penyimpanan

      Insulated hand tools harus disimpan dengan baik untuk meminimalkan risiko kerusakan pada isolasi karena penyimpanan atau pengangkutan. Insulated hand tools ini harus disimpan terpisah dari perkakas lain untuk menghindari kerusakan mekanis atau kebingungan dengan perkakas yang tidak diinsulasi. Selain itu, insulated hand tools ini harus dicegah dari kontak dengan permukaan yang terlalu panas (misalnya pipa uap) atau paparan radiasi UV yang berlebihan.

      Periksa sebelum digunakan

      Sebelum digunakan, setiap Insulated Hand Tool harus diperiksa secara visual oleh pengguna. Jika ada keraguan tentang keamanan insulated hand tool, harus dikenai pemeriksaan oleh orang yang kompeten dan jika perlu diuji ulang untuk menentukan kesesuaian atau dibuang untuk mencegah penggunaan lebih lanjut.

      Suhu

      Insulated Hand Tools harus digunakan hanya di lingkungan yang suhunya antara –20 ° C dan +70 ° C dan, untuk alat bertanda “C”, antara –40 ° C dan +70 ° C.

      Pemeriksaan berkala dan pengujian ulang listrik

      Pemeriksaan visual tahunan oleh orang yang terlatih disarankan untuk menentukan kesesuaian Insulated Hand Tool untuk layanan lebih lanjut. Jika uji ulang listrik diperlukan oleh peraturan nasional atau dalam kasus keraguan setelah pemeriksaan visual, uji dielektrik yang berlaku IEC 60900 untuk insulated hand tools harus dilakukan.

      Untuk detail, hubungi Pusat Layanan Fluke

      Model: Starter kit Fluke 117 Multimeter Teknisi Listrik plus starter kit insulated hand tools

      IB117K

      Fluke 117 Multimeter Teknisi Listrik + Starter Kit Insulated Hand Tools (5 insulated screwdrivers dan 3 insulated pliers)


      Belilah

      Mencakup:

      • Fluke 117 Multimeter Teknisi Listrik
      • ISLS3 Insulated Slotted Screwdriver 3/32, 3"
      • ISLS5 Insulated Slotted Screwdriver 5/32, 4"
      • ISLS8 Insulated Slotted Screwdriver 1/4, 5"
      • IPHS1 Insulated Phillips Screwdriver #1, 3"
      • IPHS2 Insulated Phillips Screwdriver #2, 4"
      • INLP8 Insulated Long Nose dengan Pemotong Sisi dan Area Cengkeraman
      • INDC8 Insulated Heavy Duty High Leverage Diagonal Cutter
      • INCP8 Insulated Heavy Duty Linesman Combination Plier
      • Kantong Gulungan RUP8