393 FC CAT III 1500 V True-RMS -pihtimittari iFlex-lenkkivirtapihdillä

  • 393 FC CAT III 1500 V True-rms Clamp Meter
  • The Fluke 393 clamp meter has a very thin jaw for cramped combiner boxes, but still clamps around a 34 mm cable.
  • Fluke 393 FC clamp calculates and dsiplay dc power (kVA) enerated by a solar panel
  • Measurements sent to a smartphone and the cloud via Fluke Connect software.
  • Video Player is loading.
    Current Time 0:00
    Duration 0:00
    Loaded: 0%
    Stream Type LIVE
    Remaining Time 0:00
     
    1x
      • Chapters
      • descriptions off, selected
      • subtitles off, selected
      1. 393 FC CAT III 1500 V True-rms Clamp Meter
      2. The Fluke 393 clamp meter has a very thin jaw for cramped combiner boxes, but still clamps around a 34 mm cable.
      3. Fluke 393 FC clamp calculates and dsiplay dc power (kVA) enerated by a solar panel
      4. Measurements sent to a smartphone and the cloud via Fluke Connect software.
      5. Fluke 393 FC CAT III 1500 V True-rms Clamp Meter

      Tärkeimmät ominaisuudet

      • Tee mittaukset turvallisesti CAT III 1500 V -luokan pihtimittarilla
      • Kapea haarukkapää ahtaiden liitäntärasioiden kaapeleita varten
      • Tukeva ulkokäyttöön (IP54) luokiteltu kotelointi 
      • DC-tehomittaus (kVA), napaisuuden ääni-ilmaisin ja visuaaliset jatkuvuustiedot tehostavat työskentelyä

      Tuotekatsaus: 393 FC CAT III 1500 V True-RMS -pihtimittari iFlex-lenkkivirtapihdillä

      Joustavalla lenkkivirtapihdillä varustettu 393 FC CAT III 1500 V True-rms -pihtimittari on suunniteltu aurinkosähköasentajille ja huollon ammattilaisille, jotka työskentelevät korkean DC-jännitteen ympäristöissä, esimerkiksi aurinkosähköjärjestelmien, tuulivoimaloiden, sähköisten rautateiden ja datakeskusten UPS-lähteiden parissa. Pihtimittarilla voidaan mitata mittajohtoja käyttämällä 1500 VDC ja 1000 VAC sekä pihtiosalla voidaan mitata 999,9 A DC tai AC. Mukana toimitettavan iFlex-lenkkivirtapihdin avulla jopa 2500 ampeerin AC-virtamittaukset ovat mahdollisia. 393-pihtimittarissa on kapea virtapihti, joten kaapeleihin päästään käsiksi ahtaissakin liitäntärasioissa. Lisäksi mittausjohdot on suunniteltu asentajan työtä silmällä pitäen, ja ne ovat myös CAT III 1500 V DC -turvaluokituksen mukaiset.


      Muita tärkeitä ominaisuuksia:
      • IP54-luokitus, sopii erinomaisesti ulkokäyttöön aurinko- ja tuulivoimajärjestelmissä 
      • DC-tehonmittaus näyttää lukemat kVA:na
      • Napaisuuden ääni-ilmaisin auttaa estämään virheelliset kytkennät
      • Jatkuvuutta ilmaiseva Visual Continuity -toiminto palaa näytössä kirkkaan vihreänä, mikä helpottaa pimeissä ja meluisissa ympäristöissä työskentelemistä
      • Mittaustulokset voidaan kirjata ja raportoida Fluke Connect -ohjelmistolla
      • AC-virtaa mitattaessa mukana tuleva iFlex-lenkkivirtapihti helpottaa ahtaissa paikoissa olevien kaapeleiden mittauksia.  iFlex-mittapää mahtuu ahtaisiinkin paikkoihin ja tarjoaa tarkat virtamittaukset.
       

      Vakiovarusteet:

      • Fluke 393 FC CAT III 1500 V TRMS -pihtimittari
      • Mittausjohdot, CAT III 1500 V -luokitus, suorakulmaliitin
      • iFlex 18 tuuman lenkkivirtapihti
      • TPAK-magneettiripustin
      • Laadukas kantolaukku
      • 3 vuoden takuu

      Tekniset tiedot: 393 FC CAT III 1500 V True-RMS -pihtimittari iFlex-lenkkivirtapihdillä

      Tekniset tiedot:   
      Yleistä   
      Enimmäisjännite minkä tahansa liittimen ja maan välissä  
      AC1000 V  
      DC1500 V  
      Paristot2 AA IEC LR6, alkali  
      NäyttöTaustavalaistu kaksoisnäyttö  
      Automaattinen sammutus20 minuuttia  
      Sähköinen   
      Tarkkuus   
      Tarkkuus on määritetty 1 vuoden ajan kalibroinnista, käyttölämpötiloissa 18–28 °C, suhteellinen kosteus 0–75 %. Tarkkuuden määritykset ovat seuraavassa muodossa: ±([% lukemasta ] + [ vähiten merkitsevien numerojen määrä]).
      LämpötilakerroinLisää 0,1 x määritetty tarkkuus jokaista yli 28 °C:n tai alle 18 °C:n lämpötilaa kohti
      AC-virta: Pihti   
      Alue999,9 A  
      Erottelukyky0,1 A  
      Tarkkuus2 %+ 5 numeroa (10–100 Hz) 
       2,5 % + 5 numeroa (100–500 Hz) 
      Muotokerroin (50/60 Hz)2,5 @ 600,0 A  
       3,0 @ 500,0 A  
       1,42 @ 999,9 A  
       Lisää 2 %, jos CF > 2  
      AC-virta: Lenkkivirtapihti   
      Alue999,9 A  
       2500 A  
      Erottelukyky0,1 A (≤ 999,9 A)  
       1 A (≤ 2500 A)  
      Tarkkuus3 % + 5 numeroa (10–500 Hz) 
      Muotokerroin (50/60Hz)2,5 @ 1400 A  
       3,0 @ 1100 A  
       1,42 @ 2500 A  
       Lisää 2 %, jos CF >2  
      Sijaintiherkkyys   
      NEC-symboli
      Etäisyys optimaalisesta sijainnistai2500-10 Flexi2500-18 FlexVirhe
      A12,7 mm35,6 mm±0,5 %
      B20,3 mm50,8 mm±1,0 %
      C35,6 mm63,5 mm±2,0 %
      Mittauksen epävarmuus edellyttää, että ensisijainen johdin on keskitetty optimaaliseen paikkaan, ulkoisia sähköisiä tai magneettisia kenttiä ei ole ja laite on käyttölämpötila-alueella.
          
      DC-virta   
      Alue999,9 A  
      Erottelukyky0,1 A  
      Tarkkuus2 %+ 5 numeroa[1]  
       [1]Jos käytät nollaustoimintoa (B) offsetin kompensoimiseen.
      AC-jännite   
      Alue600,0 V  
       1000 V  
      Erottelukyky0,1 V (≤ 600,0 V)  
       1 V (≤ 1000 V)  
      Tarkkuus1 % + 5 numeroa (20–500 Hz) 
      DC-jännite   
      Alue600,0 V  
       1500 V  
      Erottelukyky0,1 V (≤ 600,0 V)  
       1 V (≤ 1500 V)  
      Tarkkuus1 % + 5 numeroa  
      mV dc   
      Alue500,0 mV  
      Erottelukyky0,1 mV  
      Tarkkuus1 % + 5 numeroa  
      Virran taajuus: Pihti   
      Alue5,0 Hz...500,0 Hz  
      Erottelukyky0,1 Hz  
      Tarkkuus0,5 % RD+ 5 numeroa  
      Liipaisutaso5–10 Hz, ≥10 A  
       10–100 Hz, ≥ 5 A  
       100–500 Hz, ≥ 10 A  
      Virran taajuus: Lenkkivirtapihti   
      Alue5,0 Hz...500,0 Hz  
      Erottelukyky0,1 Hz  
      Tarkkuus0,5 % RD+ 5 numeroa  
      Liipaisutaso5–20 Hz, ≥ 25 A  
       20–100 Hz, ≥ 20 A  
       100–500 Hz, ≥ 25 A  
      Jännitteen taajuus   
      Alue5,0 Hz...500,0 Hz  
      Erottelukyky0,1 Hz  
      Tarkkuus0,5 % + 5 numeroa  
      Liipaisutaso5–20 Hz, ≥ 5 V  
       20–100 Hz, ≥ 5 V  
       100–500 Hz, ≥ 10 V  
      DC-teho   
      Alue600,0 kVA (600,0 VDC-alue)  
       1500 kVA (1500 VDC-alue)  
      Erottelukyky0,1 kVA  
       1 kVA  
      Tarkkuus2 % + 2,0 kVA  
       2 % + 20 kVA  
      Vastus   
      Alue600,0 Ω  
       6000 Ω  
       60,00 kΩ  
      Erottelukyky0,1 Ω (≤600,0 Ω)  
       1 Ω (≤6000 Ω)  
       0,01 kΩ (≤ 60,00 kΩ)  
      Tarkkuus1 % + 5 numeroa  
      Kapasitanssi   
      Alue100,0 μF  
       1000 μF  
      Erottelukyky0,1 μF (≤ 100,0 μF)  
       1 μF (≤ 1000 μF)  
      Tarkkuus1 % + 5 numeroa  
      Käynnistysvirran liipaisutaso5 A  
      Mekaaniset tiedot   
      Koko (P × L × K)281 mm x 84 mm x 49 mm  
      Paino (paristojen kanssa)520 g  
      Leukojen aukeama34 mm  
      Lenkkivirtapihdin kelan halkaisija7,5 mm  
      Lenkkivirtapihdin kaapelin pituus   
      (pihdistä liittimeen)1,8 m  
      Ympäristö   
      Käyttölämpötila–10 °C...50 °C  
      Varastointilämpötila–40 °C...60 °C  
      KäyttökosteusTiivistymätön (< 10°C)  
       ≤ 90 % RH (10–30 °C)  
       ≤ 75 % RH (30–40 °C)  
       ≤ 45 % RH (40–50 °C)  
      Käyttökorkeus2000 m  
      Varastointiympäristön korkeus12000 m  
      Kotelointiluokka (IP-luokitus)IEC 60529: IP54, ei käytössä  
      Sähkömagneettinen yhteensopivuus (EMC)   
      KansainvälinenIEC 61326-1: Kannettava, sähkömagneettinen ympäristö, IEC 61326-2-2 CISPR 11: Ryhmä 1, luokka A
       Ryhmä 1: Laite luo tai käyttää johtuvaa radiotaajuusenergiaa laitteensisäisissä toiminnoissa.
      Luokka A: Laite soveltuu käytettäväksi kaikissa tiloissa, lukuun ottamatta kotitalouksia ja tiloja, jotka on kytketty suoraan kotitalouksille tarkoitettuun yleiseen matalajännitteiseen jakeluverkkoon. Sähkömagneettisen yhteensopivuuden takaaminen saattaa olla vaikeaa muissa ympäristöissä johtuvien ja säteilevien häiriöiden vuoksi.
      Varoitus: Tätä laitteistoa ei ole tarkoitettu käytettäväksi asuinympäristössä, eikä se välttämättä takaa riittävää radiolähetysten suojausta tällaisissa ympäristöissä.
      Korea (KCC)Luokan A laite (teollinen lähetys- ja tiedonsiirtolaitteisto)
       Luokka A: Laite täyttää teollisen sähkömagneettisia aaltoja säteilevän laitteiston vaatimukset, ja myyjän tai käyttäjän on otettava se huomioon. Tämä laitteisto on tarkoitettu käytettäväksi liiketoimintaympäristöissä. Sitä ei saa käyttää kotitalouksissa.
      USA (FCC)47 CFR 15 jaos B. Tätä tuotetta pidetään vapautettuna laitteena lausekkeen 15.103 mukaan.
      Turvallisuus   
      YleistäIEC 61010-1, ympäristöhaittaluokka 2 
      MittausIEC 61010-2-032: CAT III 1500 V / CAT IV 600 V 
       IEC 61010-2-033: CAT III 1500 V / CAT IV 600 V 
      Langaton radio   
      RadiotaajuussertifiointiFCC-tunnus: T68-FBLE, IC: 6627A-FBLE 
      Langaton radiotaajuus2400 MHz...2483,5 MHz  
      Lähtöteho< 100 mW  
      YKSINKERTAISTETTU EU:N VAATIMUSTENMUKAISUUSVAKUUTUS  
      Fluke vakuuttaa täten, että tämän tuotteen sisältämä radiolaite on direktiivin 2014/53/EU mukainen.
      EU:n vaatimustenmukaisuusvakuutuksen täysimittainen teksti on saatavilla seuraavassa internetosoitteessa:  
      www.fluke.com/en-us/declaration-of-conformity   

      Mallit: 393 FC CAT III 1500 V True-RMS -pihtimittari iFlex-lenkkivirtapihdillä

      393 FC
      393 FC CAT III 1500 V True-RMS -pihtimittari iFlex-lenkkivirtapihdillä

      Osta

      Toimitukseen kuuluu:

      • Fluke 393 FC CAT III 1500 V True-RMS -pihtimittari iFlex-lenkkivirtapihdillä
      • Mittausjohdot, CAT III 1500 V -luokitus, suorakulmaliitin
      • iFlex 18 tuuman lenkkivirtapihti
      • TPAK-magneettiripustin
      • Laadukas kantolaukku
      • 3 vuoden takuu

      Fluke Connect ei ole käytettävissä kaikissa maissa.

      *Kaikki mallit eivät ole saatavilla kaikissa maissa. Tarkista asia paikalliselta Fluken jälleenmyyjältä.

      ©2025  Fluke Corporation. Kaikki tavaramerkit ovat omistajiensa omaisuutta. Älypuhelin, langaton verkkoyhteys ja tiedonsiirtosopimus eivät kuulu toimitukseen. Tallenna ensimmäiset 5 Gb maksutta. Yhteensopiva iPhone 4s -laitteen ja uudempien mallien kanssa, joissa on vähintään iOS 8 -käyttöjärjestelmä, iPad-laitteen kanssa (iPadin iPhone-ikkunassa), Samsung Galaxy S4 -laitteiden, joissa on vähintään Android 4.3.x -käyttöjärjestelmä, ja Samsung Galaxy S-, Nexus 5-, HTC One- ja One M8 -laitteiden kanssa, joissa on vähintään Android™ 4.4.x -käyttöjärjestelmä. Apple ja Applen logo ovat Apple Inc:n rekisteröityjä tavaramerkkejä Yhdysvalloissa ja muissa maissa. App Store on Apple Inc:n palvelun tuotemerkki. Google Play on Google Inc:n tavaramerkki.