RPM4 BA100K Reference Pressure Barometer

  • No image available

Características principales

  • Incertidumbre: ± 0,01% para canal único, ± 0,008% para canal doble.
  • Canal único o doble con modo de medidan en paralelo para una mayor fiabilidad.
  • Interfaces: Incluye RS232 e IEEE-488.

Descripción general del producto: RPM4 BA100K Reference Pressure Barometer

The RPM4 BA100K is a full function laboratory quality barometer intended to measure atmospheric pressure with the very highest performance. Its outstanding pressure measurement specifications are made possible by DHI's exclusive quartz reference pressure transducer (Q-RPT) modules.

Especificaciones: RPM4 BA100K Reference Pressure Barometer

 RPM4 BA100K (Single Channel)RPM4 BA100K/BA100K (Dual Channel)
Range70 kPa to 110 kPa (10 psia to 16 psia)
Power requirements85 V ac to 264 V ac, 50/60 Hz; 12 V dc, 1.2 A (battery)
Weight5 kg (11 lb)
Dimensions (H x W x D)10 cm x 22.7 cm x 24 cm (3.9 in. x 8.9 in. x 9.5 in.)
Test port connections1/8 in NPT F
Communications portsRS232 (COM1, COM2), IEEE-488.2 Resolution To 1 ppm, user adjustable To 1 ppm, user
ResolutionTo 1 ppm, user adjustable
Operating temperature15 °C to 35 °C (59 °F to 95 °F)
Warm up time30 minute temperature stabilization recommended from cold power up
VibrationMeets MIL-T-28800D
Predicted Stability1± 0.005 % of reading± 0.0032 % of reading
Precision2± 0.008 % of reading± 0.006 % of reading
Measurement Uncertainty3± 0.01 % of reading± 0.008 % of reading
1Predicted Q-RPT measurement stability limit (k=2) over one year assuming regular use of AutoZero function. AutoZero is performed by the operator by comparison with a barometric reference in absol mode. Absolute mode predicted one year stability without AutoZ is: Single Channel ± (5 Pa + 0.005 % of reading), D Channel ± (4 Pa + 0.0032 % of reading).
2Combined linearity, hysteresis, repeatability.
3Maximum deviation of the Q-RPT indication from the true value of applied spressure including precision, predicted one year stability limit, temperature effect and calibration uncertainty, combined and expanded (k=2) following the ISO “Guide to the Expression of Uncertainty in Measurement.”

Modelos: RPM4 BA100K Reference Pressure Barometer

RPM4 mhhhac/mlllac
Monitor de presión de referencia

Donde:
mhhhac indica la designación de Q-RPT alto.
c indica la clase de Q-RT (s para estándar, p para premium)

mlllac indica la designación y la clase de Q-RPT bajo. Déjelo en blanco si no hay Q-RPT bajo.

Consulte el Q-RPT y la tabla de intervalos situada debajo de "Características" para ver los Q-RPT disponibles.
RPM4 04
-1 versión de unidades de Estados Unidos, -2 versión de unidades del sistema métrico

RPM4 05
Marca de CE

RPM4 06
Calibración especial

RPM4 07
Fluido de prueba especial, Q-RPT alto (especificar fluido)

RPM4 08
Fluido de prueba especial, Q-RPT bajo (especificar fluido)

RPM4 09
-1 configuración especial, datos del aire (sólo A160K/A160K, A350K/A160K)

RPM4-LP
Monitor de baja presión, -15 a 15 kPa (-60 a 60 inH2O)

3990-803
Paquete de control de presión manual, a 3000 psi (207 bar)