  • Test the safety and functionality of AC electrical vehicle charging stations with the all-in-one solution
  • GFCI Trip Test
  • Pass/fail test results
  • Auto control pilot (CP) with waveform analysis
  • Compatible with TruTest™️ Data Management Software
In stock
$2,999.99
FREE ShippingArrives by Wednesday, Apr 09
30-day Returns
Product + Premium Care Plan
Premium Care Plan only (I already own the product)
No thanks

Product overview: Fluke FEV150 EV Charging Station Analyzer

Fluke Premium Care eligible

When you invest in your Fluke test tools, you want your money to go as far as possible. Fluke Premium Care is a paid offering that provides coverage above and beyond the original product warranty, so you don’t need to worry about unexpected downtime caused by damaged test equipment, accessories, or tools in need of calibration or repair.

Video Player is loading.
Current Time 0:00
Duration 0:00
Loaded: 0%
Stream Type LIVE
Remaining Time 0:00
 
1x
    • Chapters
    • descriptions off, selected
    • captions off, selected

      Learn more

      The FEV150 is a complete solution for safety and performance testing of AC EV charging stations with Type 1 (J1772) or Tesla type connectors. Deliver uptime reliability with Fluke’s next generation of EV Charging test solutions, designed for technicians to perform and document multiple tests safely, quickly, and efficiently without carrying multiple tools.

      The all-in-one solution includes TruTest™ EV Charging software. TruTest integrates seamlessly with the FEV150 via Bluetooth connection to provide predetermined test plans, pass/fail indications, and pre-test voltage safety information. Use the FEV150 and TruTest automation to get the job done safely, faster, and with less potential for errors.

      The FEV150 EV Charging Station Analyzer is compliant with J1772 standards.

      Applications:
      • Safety testing of charging stations
      • Performance testing of charging stations
      • Troubleshooting/repair of charging stations
      Available measurements:
      • PE (protective) earth pre-test to ensure no dangerous voltage is present
      • Visual inspection
      • GFCI Trip Test
      • Nominal voltage
      • Auto control pilot (CP) with waveform analysis
      • Error testing
      • Proximity pilot
      • Manual Control Pilot
      • Advanced GFCI Test
      Leverage TruTest automation to process test results and compile client reports with ease

      TruTest is the modern, fast, and reliable software platform to cover your reporting and documentation needs. Now you can perform asset management, data storage, and reporting on a single platform that seamlessly integrates with the FEV150 on any job. Whether you are analyzing Control Pilot waveforms or safety testing the system, TruTest guides you through each test and generates easy-to-understand reports for clients.

      • Easily manage measurement data from EVSE inspections
      • Quickly create inspections and reports
      • Control Pilot waveform analysis with easy pass/fail visuals
      • Compare site data to previous site data to see changes over time
      • Quickly access the latest firmware to update your FEV150

       

      A free 60-day demo version of TruTest is available for download. Purchase a software key to unlock the Lite or Advanced version. Compatible with Bluetooth 5.0

      Specifications: Fluke FEV150 EV Charging Station Analyzer

      The operational error specification reference for digit counts is defined as ±(% of reading +digit counts).

      The operational error for other specifications that reference a % are defined as the % of the reading unless otherwise specified. The operational error specification reference temperature for all readings is 23 °C ±5K temperature coefficient of 0.1 %/°C."

       

      Test/functionDisplay RangeMeasurement RangeOperational ErrorNominal values
      PE pre-test
      Touch voltage, safe range≤50 V ac/dc-50%--
      Touch voltage, dangerous range>50 V ac/dc0%--
      Visual inspection checklist·----
      GFCI Trip
      Quick trip30 mA, trip time limit: 0.56 sTest current: 0% to 10%100 V ac to 253 Vac, 45 Hz to 66 Hz
      Trobouble shooting 6 mA GFCI3.5 mA, no tripTest current: -10% to 0%
       10 mA, trip time limit: 2.69 sTest current: 0% to 10%
      Trobouble shooting 20 mA GFCI6 mA, no tripTest current: -10% to 0%
       30 mA, trip time limit: 0.56 sTest current: 0% to 10%
      Nominal voltage
      L1-L2/N0 V ac to 280 Vac0 Vac to 253 Vac±(3% + 3 digits)40 Hz to 70 Hz, crest factor 2
      Frequency40.00 Hz to 70.00 Hz±0.20 Hz--
      CP signal analysis
      Voltage-15.000 V to
      15.000 V
      -15.000 V to
      -2.000 V,
      2.000 V to
      15.000 V
      ±0.5 %RIN: 1 M
      0.9000 kHz to
      1.1000 kHz;
      U
      CP+ >2.000 V,
      U
      CP- <-2.000 V
      PWM duty cycle2.0 % to 98.0 %3.0 % to 97.0 %±5 digits
      Current indication0.0 A to 80.0 A--Based on duty cycle[2]
      Frequency0.9000 kHz to 1.1000 kHz0.1%
      CP state indicationA, B, C, D--Based on voltage[1]
      x1, x2--Based on frequency[1]
      CP state simulationA---->900 k ±0.2 %
      B--Upper level: 4610
      ±0.2 %[1]
      Nominal level: 2740 Ω
      ±0.2 %
      [1]
      Lower level: 1870 Ω
      ±0.2 %
      [1]
      C--Upper level: 1254.2
      ±0.2 %[1]
      Nominal level: 881.7 Ω
      ±0.2 %
      [1]
      Lower level: 611.7 Ω
      ±0.2 %
      [1]
      D--Upper level: 408.3
      ±0.2 %[1]
      Nominal level: 245.8 Ω
      ±0.2 %
      [1]
      Lower level: 130.2 Ω
      ±0.2 %
      [1]
      Fault simulationPE error (earth
      fault/PE open)
      Pass/Fail----
      CP error EPass/Fail0 +2 --
      Diode shortPass/Fail----
      Error DPass/Fail----
      PP resistor measurement
      Type 1 with cable (S3, R6, R7)
      50.0 to 499.9 ,
      500
      to 5000
      ±1.0 %--
      CP resistor measurement (R1)800 to 1200 ±1.0 %--
      [1] According to IEC 61851-1.
      [2] According to table A.8 of IEC 61851-1.
       
      General specification
      Input elctrical ratings250 V max
      50/60 Hz, max 1 A
      EV connectorSAE J1772 socket (type 1, 5P single-phase)
      Internal power consumption3W max
      Size (H x W x D)∼(263 mm x 123 mm x 63 mm)
      ∼(10.35 in x 4.84 in x 2.48 in) without the TY1 
      Weight∼0.9 kg, without the TY1 connector
      ∼1.4 kgn with the TY1 connector
      Battery4 x AA/IEC LR6 alkaline or IEC HR6 NiMH
      Temperature
      Operating-10 °C to 40 °C (14 °F to 104 °F)
      Storage-20 °C to 50 °C (-4 °F to 122 °F)
      Relative humidity
      Operating10 % to 85 %, 0 °C to 40 °C
      (32 °F to 104 °F), non-condensing
      Storageup to 95 %
      Altitude3000 m
      Ingress protectionIP40
      Wireless radio, Bluetooth 5.0
      Frequency range2400 MHz to 2483.5 MHz
      Output power<100 mW
      SafetyIEC 61010-1: Pollution Degree 2, IEC 61010-2-030, CAT II 300 V, Protection Class II
      Electromagnetic Compatibility (EMC)
      International  IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 CISPR 11: Group 1, Class A
      Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio
      frequency energy that is necessary for the internal function of the equipment itself.
      Class A: Equipment is suitable for use in all establishments other than domestic and those directly
      connected to a low-voltage power supply network that supplies buildings used for domestic
      purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other
      environments due to conducted and radiated disturbances.
      Caution: This equipment is not intended for use in residential environments and may not provide
      adequate protection to radio reception in such environments. Emissions that exceed the levels
      required by CISPR 11 can occur when the equipment is connected to a test object.
      USA (FCC)  47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.

      Models: Fluke FEV150 EV Charging Station Analyzer

      FLK-FEV150/TY1

      EV CHARGING STATION ANALYZER W/TYPE 1 PLUG, US

      Part#: 5348085

      FLK-FEV150/TY1 includes:

      • FEV150/BASIC Test Analyzer
      • FEV-CON-TY1
      • TPAK Magnetic Hanger
      • Soft Carrying Bag
      FLK-FEV150/TY1 PRO

      FLK-FEV150/TY1 + TRUTEST

      Part#: 5590687

      FLK-FEV150/TY1 includes:

      • FEV150/BASIC Test Analyzer
      • FEV-CON-TY1
      • TPAK Magnetic Hanger
      • Soft Carrying Bag
      • TruTest Software License
      FLK-FEV150/TY1/TSL

      EV CHARGING STATION ANALYZER W/TYPE 1 & TESLA TYPE PLUG, US

      Part#: 5348060

      FLK-FEV150/TY1 includes:

      • FEV150/BASIC Test Analyzer
      • FEV-CON-TS1
      • TPAK Magnetic Hanger
      • Soft Carrying Bag
      FEV150/TY1/TSL PRO

      FLK-FEV150/TY1 & TSL + TRUTEST

      Part#: 5590654

      FEV150/TY1 includes:

      • FEV150/BASIC Test Analyzer
      • FEV-CON-TS1
      • TPAK Magnetic Hanger
      • Soft Carrying Bag
      • TruTest Software License
      FLK-FEV150/TY1/FPC
      FLK-FEV150/TY1 WITH 1 YR PREMUIM CARE
      Part#: 5611298
      FLK-FPC1S-FEV150-1
      1 YR FLUKE PREMIUM CARE (NO LOANERS) FOR FEV150

      FLK-FPC3S-FEV150-1
      3 YR FLUKE PREMIUM CARE (NO LOANERS) FOR FEV150

      • bvseo_sdk, p_sdk, 3.2.1
      • CLOUD, getContent, 21.43ms
      • QUESTIONS, PRODUCT
      • bvseo-msg: HTTP status code of 404 was returned;
      • bvseo_sdk, p_sdk, 3.2.1
      • CLOUD, getReviews, 22.4ms
      • REVIEWS, PRODUCT
      • bvseo-msg: HTTP status code of 404 was returned;
      Please enable cookies to view product reviews.