Fluke 729 Automatic Pressure Calibrator

Model#:FLK-729 30GPart#:4856990UPC#:0 95969 84042 2
Fluke 729 Automatic Pressure Calibrator is rated 2.0 out of 5 by 7.
  • y_2025, m_3, d_27, h_6
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_7
  • loc_en_US, sid_3840953810996, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 235.58ms
  • REVIEWS, PRODUCT
  • Fluke 729 Automatic Pressure Calibrator - 1
  • Fluke 729 Automatic Pressure Calibrator - 2
  • Fluke 729 Automatic Pressure Calibrator
  • Video Player is loading.
    Current Time 0:00
    Duration 1:14
    Loaded: 0%
    Stream Type LIVE
    Remaining Time 1:14
     
    1x
      • Chapters
      • descriptions off, selected
      • captions off, selected
      • en (Main), selected
    • Video Player is loading.
      Current Time 0:00
      Duration 4:49
      Loaded: 0%
      Stream Type LIVE
      Remaining Time 4:49
       
      1x
        • Chapters
        • descriptions off, selected
        • en (Main), selected
      1. Fluke 729 Automatic Pressure Calibrator - 1
      2. Fluke 729 Automatic Pressure Calibrator - 2
      3. Fluke 729 Automatic Pressure Calibrator
      4. The Fluke 729 Automatic Pressure Calibrator Overview
      5. How to Perform a Pressure Calibration Using The Fluke 729

      Key features

      • Automatic pressure generation and regulation to 300 psi
      • Configure procedures for pressure transmitters and switches
      • Measure, source, and simulate 4 to 20 mA signals
      • Troubleshoot and calibrate HART smart transmitters
      • Automatically document test results
      In stock
      $12,013.99
      FREE ShippingArrives by Thursday, Apr 03
      30-day Returns
      Product + Premium Care Plan
      Premium Care Plan only (I already own the product)
      No thanks

      Product overview: Fluke 729 Automatic Pressure Calibrator

      Fluke Premium Care eligible

      When you invest in your Fluke test tools, you want your money to go as far as possible. Fluke Premium Care is a paid offering that provides coverage above and beyond the original product warranty, so you don’t need to worry about unexpected downtime caused by damaged test equipment, accessories, or tools in need of calibration or repair.

      Video Player is loading.
      Current Time 0:00
      Duration 0:41
      Loaded: 0%
      Stream Type LIVE
      Remaining Time 0:41
       
      1x
        • Chapters
        • descriptions off, selected
        • en (Main), selected

        Learn more

        Portable automatic pressure calibrator simplifies pressure calibration

        The Fluke 729 Automatic Pressure Calibrator has been designed specifically with process technicians in mind to simplify the pressure calibration process and provide faster, more accurate test results. Technicians know that calibrating pressure can be a time-consuming task, but the 729 makes it easier than ever with an internal electric pump that provides automatic pressure generation and regulation in an in an easy-to-use, rugged, portable package.

        Automatic pressure generation and control

        The ideal portable pressure calibrator, the 729 allows you to simply type in a target pressure, and the calibrator will automatically pump to the desired set-point up to 300 psi (20 bar, 2 MPa). Then, internal fine adjustment control automatically stabilizes the pressure at the requested value. You can also fill in a test template and the 729 will automatically pump to and document a multiple-point pressure calibration test at the touch of a button.

        The automatic internal fine pressure adjustment can also help compensate for minor leaks in hoses and test setups providing technicians with a stable measurement. No need to manually turn a vernier to compensate for leaks helping to eliminate the hassle of manual pumping and manual fine adjustment of test pressures.

        Easy calibration documentation

        The Fluke 729 can automatically test multiple pressure test points and automatically document the results. Calibration is as easy as typing in the starting and ending pressure, the number of test points, and the test tolerance. The 729 does the work for you by documenting and flagging out-of-tolerance test results in red on the graphical display for:

        • Applied pressure
        • Measured mA, mV, or digital PV
        • % error for each test point

        With Fluke Connect® compatibility, the 729 enables a user to perform remote monitoring using the Fluke Connect mobile app to manage and store pressure measurements and logging events. The app even allows for easy sharing so the whole team can access measurements without needing to be in the facility.

        Upload and manage documented calibration results with DPCTrack2™ Calibration Management Software, making it easy to manage your instrumentation, create scheduled tests and reports, and manage calibration data.

        HART communication

        Built-in HART communication capabilities enable HART transmitter mA adjustments, HART configuration, and the ability to adjust to applied 0% and 100% values. You can also do configuration tasks such as changing a transmitter tag, measurement units, and ranging. Other supported HART commands include setting fixed mA outputs for troubleshooting, read device configuration, and variables and read device diagnostics.

        Rugged, portable design

        The 729 is tested and warranted to withstand a 1-meter drop test so it is ready for field instrumentation calibration work. With three ranges to choose from, 30 psi (2 bar, 200 kPa), 150 psi (10 bar, 1 MPa) and 300 psi (20 bar, 2 MPa), Fluke 729 Automatic Pressure Calibrators are designed to perform when and where you need them. You can also measure temperature with optional 720RTD probe for performing custody transfer calibrations. A standard semi-rigid carrying case designed for field work, with room in the case to store test hoses, fittings, test leads, and small hand tools means it’s easy to carry everything needed for field pressure calibrations.

        Attach one of 50 Fluke 750 Series Pressure Modules to expand the pressure range outside of the internal pump specifications. For greater accuracy and resolution on low pressure calibrations, the Fluke 729 can integrate an external Fluke 750 Series Pressure Module into the test workflow, greatly expanding the calibrators capabilities in low pressure ranges.

        What's in the box:

        • Fluke 729 Automatic Pressure Calibrator
        • Li-Ion battery charger and adapters
        • Quick-Connect pressure fitting, hose and adapter starter kit
        • (1 pair) Stackable test leads
        • (1 set) AC280 SureGrip™ hook clips
        • (1 set) AC175 alligator clips
        • (1 pair) TP220 test probes (red, black)
        • USB communication cable
        • TPAK ToolPak™ Magnetic Meter Hanger Carrying case with shoulder strap and accessories pouch
        • DPCTrack2™ trial calibration management software
        • Traceable certificate of calibration
        • Quick Reference Guide
        • 3-year warranty

        Specifications: Fluke 729 Automatic Pressure Calibrator

        Pressure specification*
        One-year specification 0.02% of full scale
        Control specification 0.005% full scale minimum
        *See manual for detailed specifications

         

        Model
        729 30G
        Psi range, resolution-12.0000 to 30.0000 psi
        Bar range, resolution-0.82737 to 2.06842 bar
        kPa range, resolution-82.737 to 206.843 kPa
        CommentNo wireless communication
        729 150G
        Psi range, resolution-12.000 to 150.000 psi
        Bar range, resolution-0.8273 to 10.3421 bar
        kPa range, resolution-82.73 to 1034.21 kPa
        CommentNo wireless communication
        729 300G
        Psi range, resolution-12.000 to 300.000 psi
        Bar range, resolution-0.8273 to 20.6843 bar
        kPa range, resolution-82.73 to 2068.43 kPa
        CommentNo wireless communication
        729 30G FC
        Psi range, resolution-12.0000 to 30.0000 psi
        Bar range, resolution-0.82737 to 2.06842 bar
        kPa range, resolution-82.737 to 206.843 kPa
        CommentWireless communication for Fluke Connect
        729 150G FC
        Psi range, resolution-12.000 to 150.000 psi
        Bar range, resolution-0.8273 to 10.3421 bar
        kPa range, resolution-82.73 to 1034.21 kPa
        CommentWireless communication for Fluke Connect
        729 300G FC
        Psi range, resolution-12.000 to 300.000 psi
        Bar range, resolution-0.8273 to 20.6843 bar
        kPa range, resolution-82.73 to 2068.43 kPa
        CommentWireless communication for Fluke Connect
        729CN 200K
        Psi range, resolution-12.0000 to 30.0000 psi
        Bar range, resolution-0.82737 to 2.06842 bar
        kPa range, resolution-82.737 to 206.843 kPa
        CommentFor China, no wireless communication
        729CN 1M
        Psi range, resolution-12.000 to 150.000 psi
        Bar range, resolution-0.8273 to 10.3421 bar
        kPa range, resolution-82.73 to 1034.21 kPa
        CommentFor China, no wireless communication
        729CN 2M
        Psi range, resolution-12.000 to 300.000 psi
        Bar range, resolution-0.8273 to 20.6843 bar
        kPa range, resolution-82.73 to 2068.43 kPa
        CommentFor China, no wireless communication
        729CN 200K FC
        Psi range, resolution-12.0000 to 30.0000 psi
        Bar range, resolution-0.82737 to 2.06842 bar
        kPa range, resolution-82.737 to 206.843 kPa
        CommentFor China, wireless communication for Fluke Connect
        729CN 1M FC
        Psi range, resolution-12.000 to 150.000 psi
        Bar range, resolution-0.8273 to 10.3421 bar
        kPa range, resolution-82.73 to 1034.21 kPa
        CommentFor China, wireless communication for Fluke Connect
        729CN 2M FC
        Psi range, resolution-12.000 to 300.000 psi
        Bar range, resolution-0.8273 to 20.6843 bar
        kPa range, resolution-82.73 to 2068.43 kPa
        CommentFor China, wireless communication for Fluke Connect
        729JP 200K
        kPa range, resolution-82.737 to 206.843 kPa
        CommentFor Japan, no wireless communication
        729JP 1M
        kPa range, resolution-82.73 to 1034.21 kPa
        CommentFor Japan, 1 MPa range, no wireless communication
        729JP 2M
        kPa range, resolution-82.73 to 2068.43 kPa
        CommentFor Japan, 2 MPa range, no wireless communication
        729JP 200K FC
        kPa range, resolution-82.737 to 206.843 kPa
        CommentFor Japan, wireless communication for Fluke Connect
        729JP 1M FC
        kPa range, resolution-82.73 to 1034.21 kPa
        CommentFor Japan, wireless communication for Fluke Connect
        729JP 2M FC
        kPa range, resolution-82.73 to 2068.43 kPa
        CommentFor Japan, wireless communication for Fluke Connect

         

        Electrical specification
        All specifications are valid to 110% of range, except 24 mA source and simulate which are valid to 100% of range.
        Ranges
        mA measure, source and simulate0 mA to 24 mA
        Volts dc measure0 V dc to 30 V dc
        Resolution
        mA dc source, simulate and measure1 μA
        Voltage dc measurement1 mV
        Accuracy0.01% ±2 LSD all ranges (at 23 °C ±5 °C)
        Stability20 ppm of full scale /°C from -10 °C to +18 °C and 28 °C to +50 °C
        mA simulate external voltage requirement12 V dc to 30 V dc
        Loop compliance voltage24 V dc @ 20 mA
        mA simulate external voltage requirement12 V dc to 30 V dc
        Temperature measurement only/100 Ω Pt(385) RTD-50 °C to 150 °C (-58 °F to 302 °F)
        Temperature resolution0.01 °C (0.01 °F)
        Temperature accuracy±0.1 °C (0.2 °F) ±0.25 °C (±0.45 °F) combined uncertainty when using 720 RTD probe (optional accessory)
        Drive capability1200 Ω without HART resistor, 950 Ω with internal HART resistor
        Mechanical specification
        Size (HxWxL)7 x 27.94 x 17.27 cm (2.75 x 11 x 6.8 in)
        Weight6.5 lbs., 2.95 kg
        Ingress protectionIP54
        Environmental specification
        Operating temperature-10 °C to 50 °C for measurement, 0 °C to 50 °C for pressure control
        Operating temperature with battery-10 °C to 40 °C
        Battery will only charge to 40 °C
        Storage temperature-40 °C to 60 °C
        Operating altitude3000 m
        Storage altitude13000 m
        Wireless (729 FC only)
        Radio frequency certificationFCC ID: T68-FBLE IC:6627A-FBLE
        Wireless radio frequency range2412 MHz to 2462 MHz

        Models: Fluke 729 Automatic Pressure Calibrator

        FLK-729 30G
        Fluke 729 Automatic Pressure Calibrator 30 psi, 2 bar range, no wireless communication
        Part#: 4856990
        UPC#: 0 95969 84042 2
        FLK-729 150G
        Fluke 729 Automatic Pressure Calibrator 150 psi, 10 bar range, no wireless communication
        Part#: 4856983
        UPC#: 0 95969 84041 5
        FLK-729 300G
        Fluke 729 Automatic Pressure Calibrator 300 psi, 20 bar range, no wireless communication
        Part#: 4856976
        UPC#: 0 95969 84040 8
        FLK-729 30G FC
        Fluke 729 Automatic Pressure Calibrator 30 psi, 2 bar range, includes wireless communication for Fluke Connect
        Part#: 4856907
        UPC#: 0 95969 84033 0
        FLK-729 150G FC
        Fluke 729 Automatic Pressure Calibrator 150 psi, 10 bar range, includes wireless communication for Fluke Connect
        Part#: 4856894
        UPC#: 0 95969 84032 3
        FLK-729 300G FC
        Fluke 729 Automatic Pressure Calibrator 300 psi, 20 bar range, includes wireless communication for Fluke Connect
        Part#: 4856882
        UPC#: 0 95969 84031 6
        FLK-729CN 200K
        Part#: 4856934
        UPC#: 0 95969 84036 1
        FLK-729CN 1M
        Part#: 4856929
        UPC#: 0 95969 84035 4
        FLK-729CN 2M
        Part#: 4856918
        UPC#: 0 95969 84034 7
        FLK-729CN 200K FC
        Part#: 4856811
        UPC#: 0 95969 84027 9
        FLK-729CN 1M FC
        Part#: 4856809
        UPC#: 0 95969 84026 2
        FLK-729CN 2M FC
        Part#: 4856792
        UPC#: 0 95969 84025 5
        FLK-729PLUS 2M
        Part#: 4966530
        UPC#: 0 95969 86643 9
        FLK-729PLUS 1M
        Part#: 4966548
        UPC#: 0 95969 86644 6
        FLK-729PLUS 200K
        Part#: 4966553
        UPC#: 0 95969 86645 3
        FLK-729JP 200K
        Part#: 4856965
        UPC#: 0 95969 84039 2
        FLK-729JP 1M
        Part#: 4856952
        UPC#: 0 95969 84038 5
        FLK-729JP 2M
        Part#: 4856941
        UPC#: 0 95969 84037 8
        FLK-729JP 200K FC
        Part#: 4856866
        UPC#: 0 95969 84030 9
        FLK-729JP 1M FC
        Part#: 4856848
        UPC#: 0 95969 84029 3
        FLK-729JP 2M FC
        Part#: 4856830
        UPC#: 0 95969 84028 6
        FPC1S-FLUKE729-1

        Premium Care 1-Year Standard Plan for Fluke 729

        Part#: 5575262

        Includes:

        • Premium Care 1-Year Standard Plan
        FPC3S-FLUKE729-1

        Premium Care 3-Year Standard Plan for Fluke 729

        Part#: 5575270

        Includes:

        • Premium Care 3-Year Standard Plan
        • y_2025, m_3, d_27, h_6CST
        • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
        • cp_1, bvpage1
        • co_hasquestionsanswers, tq_5
        • loc_en_US, sid_3840953810996, prod, sort_[SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING)]
        • clientName_fluke
        • bvseo_sdk, p_sdk, 3.2.1
        • CLOUD, getContent, 114.28ms
        • QUESTIONS, PRODUCT
        • y_2025, m_3, d_27, h_6
        • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
        • cp_1, bvpage1
        • co_hasreviews, tv_0, tr_7
        • loc_en_US, sid_3840953810996, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
        • clientName_fluke
        • bvseo_sdk, p_sdk, 3.2.1
        • CLOUD, getReviews, 27.93ms
        • REVIEWS, PRODUCT
        Please enable cookies to view product reviews.