Fluke 975V AirMeter™ with Velocity Probe

Model#:Fluke 975VPart#:2666111UPC#:0 95969 35309 0
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 145.92ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Discontinued

Key features

Read more
This product is discontinued or reclassified

Product overview: Fluke 975V AirMeter™ with Velocity Probe

One Tool. Get More Done.

The Fluke 975 AirMeter test tool raises indoor air monitoring to the next level by combining five powerful tools in one, rugged and easy-to-use handheld device. Use the Fluke 975 to optimize HVAC ventilation settings for ASHRAE 62 recommendations, to actively monitor conditions that promote a productive environment, and quickly and accurately address occupant comfort complaints the first time. The Fluke 975 measures:

  • Temperature
  • Velocity
  • Humidity
  • CO2
  • CO

Use the Fluke 975 AirMeter test tool to:

  • Respond to comfort-related calls from occupants.
  • Verify the operation of building HVAC control systems.
  • Determine whether adequate ventilation exists.
  • Monitor air flow and velocity.
  • Test for dangerous carbon monoxide leaks.
  • Perform duct traversals.
  • Optimize HVAC systems to manage energy costs

Specifications: Fluke 975V AirMeter™ with Velocity Probe

Measured Specifications
TemperatureRange-20°C to 50°C (-5°F to 122°F)
Display resolution0.1°C (0.1°F)
Accuracy±0.9°C / ±1.62°F from 40°C to 60°C
±0.5°C / ±1.00°F from 5°C to 40°C
±1.1°C / ±1.98°F from -20°C to 5°C
Relative humidityRange10% to 90% RH, non-condensing
Display Resolution1%
Accuracy±2% RH (10% RH to 90% RH)
Air velocityRange50.0 fpm to 3000 fpm
0.25 m/sec to 15 m/sec
Display Resolution1 fpm (0.005 m/sec)
Accuracy±4% or 4 fpm1
±4% or 0.02 m/sec1 whichever is greater
1. Accuracy specification only valid for velocity readings above 50 fpm.
C0Range0 to 500 ppm
Display Resolution1 ppm
Accuracy±5% or ±3 ppm, whichever is greater, @ 20°C and 50% RH
C02Range0 to 5000 ppm
Display Resolution1 ppm
AccuracyWarm up time 1 min (5 minutes for full specification) 2.75% + 75 ppm
Calculated Specifications
Dew point temperatureRange-44°C to 50°C, (-47°F to 122°F)
Display Resolution0.1°C (0.1°F)
Accuracy±1°C when temp: -20°C to 50°C RH: 40% to 90%
±2°C when temp: -20°C to 50°C RH: 20% to 40%
±4°C when RH: 10% to 20%
Wet bulb temperatureRange-16°C to 50°C, (3°F to 122°F)
Display Resolution0.1°C, (0.1°F)
Accuracy±1.2°C when RH: 20% to 90% temp: -20°C to 60°C
±2.1°C when RH: 10% to 20%
Volume flow rate (in a duct)Range0 to 3,965 M3/m, (0 to 140,000 cfm)
Display Resolution0.001 M3/min, (1 cfm)
AccuracyN/A: The volume flow calculation will be a simple average of the data points times the duct area
% outside air (based on temperature)Range0 to 100%
Display Resolution0.1
% outside air (based on CO2)Range0 to 100%
Display Resolution0.1% N/A
General Specifications
Operating and storage temperature-20°C to 50°C (-4°F to 122°F)
Humidity10% to 90% (non-condensing)
AltitudeUp to 2000 m (6562 ft)
Shock and vibrationMIL-PRF-28800F: Class 2
Multi-language interfaceEnglish, French, Spanish, Portuguese and German
BatteryRechargeable Li-Ion (primary), three-AA (backup)
Data logging25,000 records (continuous), 99 records (discrete)
WarrantyTwo-years

Models: Fluke 975V AirMeter™ with Velocity Probe

Fluke 975V
Fluke 975V AirMeter™ with Velocity
Part#: 2666111
UPC#: 0 95969 35309 0
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 52.78ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 21.94ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Please enable cookies to view product reviews.