Fluke 107 Palm-sized, CAT III Digital Multimeter

Fluke 107 Pocket Digital Multimeter is rated 5.0 out of 5 by 28.
  • y_2024, m_11, d_24, h_6
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_2, bvpage2n
  • co_hasreviews, tv_19, tr_9
  • loc_en_US, sid_4329854271540, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 223.99ms
  • REVIEWS, PRODUCT
  • Fluke 107 掌上数字万用表

Key features

  • CAT III 600 V safety rating
  • Current and voltage measurements
  • Measures resistance and continuity to check for broken wires
  • Data hold and backlit display to keep you working safe and fast

Product overview: Fluke 107 Palm-sized, CAT III Digital Multimeter

The Fluke 107 is a compact, palm size easy-to-use digital multimeter made to fit the way you work. It is the perfect first-pass troubleshooting tool; small enough to fit in a shirt pocket yet tough enough to withstand daily use, including a 1-meter drop test. For everyday applications where true-rms accuracy isn’t needed, the Fluke 107 delivers reliable measurements time after time. With a CAT III 600 V safety rating, you don’t need to compromise safety. The Fluke 107 offers a comfortable grip, weighs only 200 g, and is easy to carry. 
 
Fluke 107 measurement test functions

  • AC and DC voltage
  • AC and DC current
  • Resistance
  • Capacitance
  • Diode
  • Frequency and duty-cycle

 
Fluke 107 comes ready to work
The Fluke 107 comes with a TL75 Hard Point™ Test Lead Set. It’s one pair (red, black) of 48 inch (1.22 meter) test leads with right-angle, shrouded banana plugs. The meter also includes a SmartStrap™ intelligent magnetic multi-purpose lanyard that lets you hang the Fluke 107 from any ferrous surface or support the meter at an angle for easy viewing.

What's in the box:

  • Fluke 107 palm-sized digital multimeter
  • (1 pair) TL75 Hard Point™ Test Leads
  • (2) AAA batteries (installed)
  • SmartStrap™ intelligent magnetic, multi-purpose lanyard
  • 1-year warranty.

Specifications: Fluke 107 Palm-sized, CAT III Digital Multimeter

Accuracy is available for one year after calibration, operating from 18 °C to 28 °C and relative humidity from 0% to 75%. The format of the accuracy specification is: ± ([% of reading] + [least significant digit])

Precision specifications
AC voltage
(40 Hz to 500 Hz)1
RangeResolutionAccuracy
6.000 V
60.00 V
600.0 V
0.001 V
0.01 V
0.1 V
1.0 % + 3
DC voltage6.000 V
60.00 V
600.0 V
0.001 V
0.01 V
0.1 V
0.5 % + 3
Exchange millivolts600.0 mV0.1 mV3.0 % + 3
Diode test22.000 V0.001 V10 %
Resistance
(ohm)
400.0 Ω
4.000 kΩ
40.00 kΩ
400.0 kΩ
4.000 MΩ
40.00 MΩ
0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
0.5 % + 3
0.5 % + 2
0.5 % + 2
0.5 % + 2
0.5 % + 2
1.5% + 3
Capacitor350.00 nF
500.0 nF
5.000 μF
50.00 μF
500.0 μF
1000 μF
0.01 nF
0.1 nF
0.001 μF
0.01 μF
0.1 μF
1 μF
2 % + 5
2 % + 5
5 % + 5
5 % + 5
5 % + 5
5 % + 5
Frequency4 Hz
(10 Hz – 100 kHz)
50.00 Hz
500.0 Hz
5.000 kHz
50.00 kHz
100.0 kHz
0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
0.1 kHz
0.1 % + 3
Duty cycle41 % to 99 %0.10 %1 % typical case5
AC current
(40 Hz - 200 Hz)
4.000 A
10.00 A
0.001 A
0.01 A
1.5 % + 3
DC4.000 A
10.00 A
0.001 A
0.01 A
1.5 % + 3
  1. All AC current, frequency, and duty cycle are specified from 1% to 100% of the range. Input values below 1% of range are not specified.
  2. Typically, the open circuit test voltage is 2.0 V and the short circuit current is < 0.6 mA.
  3. The parameters do not include errors due to test lead capacitance and capacitor substrate (up to 1.5 nF in the 50 nF range).
  4. All AC current, frequency, and duty cycle are specified from 1% to 100% of the range. Input values below 1% of range are not specified.
  5. Typically, the frequency is 50 Hz or 60 Hz and the duty cycle is 10% to 90%.
FeaturesOverload protectionInput impedance (nominal value)Common mode rejection ratioNormal mode rejection ratio
AC voltage600 V 1>10 MΩ <100 pF 2>60 dB at 50 Hz or 60 Hz at DC current
Exchange millivolts600 mV>1M, <100 pF>80 dB at 50 Hz or 60 Hz
DC voltage600 V 1>10 MΩ <100 pF>100 dB at 50 Hz or 60 Hz at DC current>60 dB at 50 Hz or 60 Hz
  1. Up to 6 x 105 V Hz
  2. For medium voltage (alternating current), the input impedance is approximately 1 MΩ.
General technical indicators
The highest voltage applied to any terminal and ground600 V
Display (LCD)6000 counts, updated three times per second
Type of batteryTwo AAA batteries (NEDA 24A, IEC LR03)
Battery lifeAt least 200 hours
Temperature
Operating temperature0 °C to 40 °C
Storage temperature-30 °C to 60 °C
Relative humidity
Working humidityNo condensation below 10 °C
≤ 90 % at 10 °C to 30 °C; ≤ 75 % at 30 °C to 40 °C
Working humidity, 40 MΩ range≤ 80 % at 10 °C to 30 °C; ≤ 70 % at 30 °C to 40 °C
Altitude
Working elevation2000 m
Storage altitude12,000 m
Temperature coefficient0.1 X (specified accuracy) / °C (<18 °C or >28 °C)
Current input fuse protection11A, 1000V fast-melting type, must use Fluke designated parts
Volume (height x width x length)142 mm x 69 mm x 28 mm
Weight200 g
Protection levelIEC 60529: IP 40
SafetyIEC 61010-1: 600 V CAT III, pollution degree 2
Electromagnetic environmentIEC 61326-1: Portable
Electromagnetic compatibilityApplicable only in Korea. Class A equipment (industrial broadcasting and communication equipment)1
1 This product meets the requirements of industrial (Class A) electromagnetic wave equipment, which should be noted by the seller or user. The device is suitable for use in a work environment, not a home environment.

Models: Fluke 107 Palm-sized, CAT III Digital Multimeter

Fluke 107

Fluke 107 Palm-sized, CAT III Digital Multimeter


Buy it

Includes:

  • Fluke 107 Palm-sized, CAT III Digital Multimeter
  • TL75 Hard Point™ Test Lead Set
  • Two AAA batteries (installed)
  • SmartStrap™ intelligent magnetic multi-purpose lanyard
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 128.15ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Rated 5 out of 5 by from Lifelong Fluke User What can I say? Fluke puts out products that perform as expected. This product has the power of a large multimeter, packed into a pocket size meter.
Date published: 2020-09-27
  • y_2024, m_11, d_24, h_6
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_2, bvpage2n
  • co_hasreviews, tv_19, tr_9
  • loc_en_US, sid_4329854271540, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 24.39ms
  • REVIEWS, PRODUCT
Please enable cookies to view product reviews.