Fluke 87V MAX True-rms Digital Multimeter

Fluke 87V MAX True-rms Digital Multimeter is rated 4.7 out of 5 by 25.
  • y_2025, m_3, d_12, h_9
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_2, bvpage2n
  • co_hasreviews, tv_10, tr_15
  • loc_en_US, sid_4330750410804, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 166.4ms
  • REVIEWS, PRODUCT
  • Fluke 87V MAX True-rms Digital Multimeter
  • Fluke 87V MAX digital multimeter with leads, probes, temperature adapter
  • The 87V MAX work around wet, humid pumps
  • 87V MAX with totally waterproof and dust proof IP67 case
  • 87V MAX with dust proof IP67 case
  • Video Player is loading.
    Current Time 0:00
    Duration 0:00
    Loaded: 0%
    Stream Type LIVE
    Remaining Time 0:00
     
    1x
      • Chapters
      • descriptions off, selected
      • subtitles off, selected
      1. Fluke 87V MAX True-rms Digital Multimeter
      2. Fluke 87V MAX digital multimeter with leads, probes, temperature adapter
      3. The 87V MAX work around wet, humid pumps
      4. 87V MAX with totally waterproof and dust proof IP67 case
      5. 87V MAX with dust proof IP67 case
      6. 87V MAX Global

      Key features

      • Withstands drops up to 4-meters (13 feet) with industrial strength casing and holster
      • Waterproof, dustproof IP67 case for the most extreme work sites
      • Premium TL175 TwistGuard™ test leads
      • Double the battery life of the 87V (up to 800 hours); backlit keys for dark environments

      Product overview: Fluke 87V MAX True-rms Digital Multimeter

      The 87V MAX contains all the trusted features of the most popular digital multimeter used today, the Fluke 87V, and then some. From wet, dusty or dark environments to long days, the 87V MAX was designed to help you finish the most on a work site. It features a unique function for accurate voltage and frequency measurements on variable frequency motor drives (VFDs) and other electrically noisy equipment; using true-rms ac voltage and current for accurate measurements on non-linear signals.

      Fluke’s most rugged digital multimeter

      The 87V MAX is built with an IP67 rated, industrial-strength case and a removable holster. The holster doubles as a test probe holder for easier, one-handed operation. This meter is fully waterproof and dust proof keep working reliably no matter where your job takes you.

      4-meter Drop tested

      • Industrial-strength is no joke, the meter is designed to survive drops up to 4-meters (13 feet).

      Withstands hot and cold environments

      • Rely on accurate measurements with the extended operating temperature range of -40 °C (for up to 20 minutes) to +55 °C.

      Easy-to-read measurements

      The large display digits and 2-level bright, white backlight and backlit keypad buttons make for increased visibility. Along with the high resolution 19,999 count display mode allows you to read measurements easily in any work environment. This multimeter will run for up to 800 hours of battery life and offers measurement capabilities

      • up to 1000 V ac and dc and up to 10 A (20 A for 30 seconds),
      • frequency to 200 kHz
      • min/max/average recording, plus 250 μs Peak min-max to capture variations automatically or
      • use the built-in thermometer.

      For a complete comparison of specifications, please visit our selection guide for digital multimeters.

       
       Fluke 87V MAX True-rms Digital MultimeterFluke 87V Industrial MultimeterFluke 289 True-RMS Data Logging MultimeterFluke 179 True-RMS Digital MultimeterFluke 1587 FC Insulation Multimeter
      CAT ratingCAT III 1000 V
      CAT IV 600 V
      CAT III 1000 V
      CAT IV 600 V
      CAT III 1000 V
      CAT IV 600 V
      CAT III 1000 V
      CAT IV 600 V
      CAT III 1000 V
      CAT IV 600 V
      True-rms readings
      Voltage AC/DC1000 V1000 V1000 V1000 V1000 V
      Current AC/DC10 A10 A10 A10 A400 mA
      Resistance50 MΩ50 MΩ500 MΩ50 MΩ50 MΩ
      Capacitance9,999 μF9,999 μF100,000 μF9,999 μF9,999 μF
      Temperature-200 °C to 1090 °C-200 °C to 1090 °C-200 °C to 1350 °C-40 °C to 400 °C-40 °C to 537 °C
      Additional
      measurement
      capabilities
      Conductance,
      continuity/diode test,
      duty cycle,
      frequency, microamps,
      motor drive (VFD)
      measurement,
      pulse width,
      elative reference
      Frequency,
      continuity/diode test,
      motor drive (VFD)
      measurement,
      duty cycle,
      microamps, analog
      bar graph, relative
      reference
      Conductance (50ns),
      duty cycle,
      frequency,
      continuity/diode test,
      low input
      impedance,
      microamps,
      pulse width
      Continuity/diode test,
      frequency,
      microamps
      Frequency, Pi/DAR
      timed ratio tests,
      continuity/diode test, motor drive (VFD)
      measurement,
      microamps, relative
      reference
      IP ratingIP 67IP 30IP 42--
      Battery life800 hours400 hours200 hours200 hours1000 hours
      Drop test4 meters3 meters---
      Backlit keypadYesNoNoNoNo

      What's in the box:

      • Fluke 87V MAX True-rms Digital Multimeter
      • TL175 TwistGuard® test leads
      • AC175 Alligator clips
      • 80BK-A temperature probe
      • Removable holster with test lead storage
      • Three AA batteries (installed) 

      Specifications: Fluke 87V MAX True-rms Digital Multimeter

      Electrical Specifications
      DC VoltageRange0.1 mV to 1000 V
      Accuracy±(0.05% + 1)
      Maximum resolution0.1 mV
      AC VoltageRange0.1 mV to 1000 V
      Accuracy±(0.7% + 4) true-rms
      AC bandwidth20 kHz with low pass filter; 3 dB @ 1 kHz
      Maximum resolution0.1 mV
      DC CurrentRange0.1 μA to 10 A
      (20 A for 30 seconds maximum)
      Amps accuracy±(0.2% + 2)
      Maximum resolution0.1 µA
      AC CurrentRange0.1 μA to 10 A
      (20 A for 30 seconds maximum)
      Amps accuracy±(1.0% + 2) true-rms
      Maximum resolution0.1 µA
      ResistanceRange0.1 Ω to 50 MΩ
      Accuracy±(0.2% + 1)
      Maximum resolution0.1 Ω
      CapacitanceRange0.01 nF to 9999 μF
      Accuracy±(1% + 2)
      Maximum resolution0.01 nF
      FrequencyRange0.5 Hz to 199.99 kHz
      Accuracy±(0.005% + 1)
      Maximum resolution0.01 Hz
      Duty cycleMaximum duty cycle99.9%
      Accuracy±(0.2% per kHz + 0.1%)
      Maximum resolution0.1%
      Temperature measurement range–200.0 °C to 1090 °C
      –328.0 °F to 1994.0 °F
      excluding probe
      80 BK temperature probe–40.0 °C to 260 °C, ± 2.2 °C or 2% whichever is greater
      –40.0 °F to 500 °F, ± 4.0 °F or 2% whichever is greater
      ConductanceMaximum conductance60.00 nS
      Accuracy±(1.0% + 10)
      Maximum resolution0.01 nS
      Diode testRange2 V
      Resolution0.001V
      Accuracy±(1% + 1)
      Diagnostics and data storagePeak Min/Max250 μS
      Min/Max/AvgYes
      Reading hold/Auto (Touch) HoldYes
      Relative referenceYes
      DisplayDigital6000 counts updates 4/second
      19,999 counts in high–resolution mode
      Analog bar graph32 segments, updates 40/second
      BacklightTwo level
      Low pass filter (VFD measurements)Yes
      Input Alert™Yes
      Safety Specifications
      Safety ratingIEC61010-1: Pollution Degree 2
      IEC 61010-2-033: CAT IV 600 V, CAT III 1000 V
      Agency approvalsCE, CSA
      Mechanical and General Specifications
      IP ratingIEC 60529: IP67
      PowerThree AA batteries. 800 hours typical, without backlight
      Size6.0 x 10.1 x 21.5 cm (with holster)
      Weight698.5 g (with holster)
      WarrantyLimited lifetime
      Environmental Specifications
      Operating temperature-15 °C to 55 °C, to -40 °C for 20 minutes when taken from 20 °C
      Storage temperature-40 °C to + 60 °C
      Humidity (without condensation)0% – 90% (0 °C – 35 °C)
      0% – 70% (35 °C – 55 °C)
      Operating altitude2000 m

      Models: Fluke 87V MAX True-rms Digital Multimeter

      Fluke 87V MAX

      Fluke 87V MAX True-rms Digital Multimeter


      Buy it

      Includes:

      • TL175 TwistGuard® test leads
      • AC175 Alligator clips
      • 80BK-A temperature probe
      • Removable holster with test lead storage
      • Three AA batteries (installed)
      • bvseo_sdk, p_sdk, 3.2.1
      • CLOUD, getContent, 125.02ms
      • QUESTIONS, PRODUCT
      • bvseo-msg: HTTP status code of 404 was returned;
      • y_2025, m_3, d_12, h_9
      • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
      • cp_2, bvpage2n
      • co_hasreviews, tv_10, tr_15
      • loc_en_US, sid_4330750410804, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
      • clientName_fluke
      • bvseo_sdk, p_sdk, 3.2.1
      • CLOUD, getReviews, 23.79ms
      • REVIEWS, PRODUCT
      Please enable cookies to view product reviews.