Product selection guide: 190 Series II

Use our product selection guide to find the portable oscilloscope that fits your needs best.
 
RemoveRemove
 
 
Fluke 190-062/S ScopeMeter® Test Tool front view
Discontinued
Fluke 190-102 ScopeMeter® Test Tool
Discontinued
 
Fluke 190-062 ScopeMeter® Test ToolFluke 190-102 ScopeMeter® Test Tool
 
ApplicationIndustrial process controlIndustrial automation controls 
Bandwidth60 MHz100 MHz 
Sample rate625 Msa/s1.25 Gsa/s 
LCDColor CCFL backlight 320 x 240Color CCFL backlight 320 x 240 
Input channels2 Scope and DMM2 Scope and DMM 
Bandwidth60 MHz100 MHz 
Sample rate625 Msa/s1.25 Gsa/s 
Scope mode memory depth10,000 points per input10,000 points per input 
Independently isolated inputs1000 V CAT III / 600 V CAT IV1000 V CAT III / 600 V CAT IV 
Rated input voltage1000 V CAT III / 600 V CAT IV1000 V CAT III / 600 V CAT IV 
Floating voltage (maximum voltage between earth ground and any terminal either signal input or shielding)1000 V CAT III / 600 V CAT IV1000 V CAT III / 600 V CAT IV 
Input channels2 Scope and DMM2 Scope and DMM 
Independently isolated inputs1000 V CAT III / 600 V CAT IV1000 V CAT III / 600 V CAT IV 
Rated input voltage1000 V CAT III / 600 V CAT IV1000 V CAT III / 600 V CAT IV 
Floating voltage (maximum voltage between earth ground and any terminal either signal input or shielding)1000 V CAT III / 600 V CAT IV1000 V CAT III / 600 V CAT IV 
Advanced triggering   
Cursors   
Advanced automatic measurementsVpwm AC & Vpwm AC+DC. Special amplitude measurement for pulse width modulated frequency motor drive.Vpwm AC & Vpwm AC+DC. Special amplitude measurement for pulse width modulated frequency motor drive. 
Power application measurementsPower (W), VA, VAR and Power Factor (PF)Power (W), VA, VAR and Power Factor (PF) 
FFT / Harmonic displayFFT, frequency spectrumFFT, frequency spectrum 
TrendPlot™Dual trend plot up to 22 daysDual trend plot up to 22 days 
ScopeRecord™Dual input up to 48 hrsDual input up to 48 hrs 
Auto capture last 100 screensReplay last 100 screensReplay last 100 screens 
PASS / FAIL waveform referenceCompare reference store on pass or failCompare reference store on pass or fail 
Digital persistenceShort, med, long and infiniteShort, med, long and infinite 
PC interfaceIsolated USBIsolated USB 
External memoryUSB memory device portUSB memory device port 
Time base range10 ns/Div to 2 min/Div5 ns/Div to 2 min/Div 
Input sensitivity2 mV/Div to 100 V/Div2 mV/Div to 100 V/Div 
Isolated / differential inputs   
Operating temperature-10 °C to +50 °C (+14 °F to +122 °F)-10 °C to +50 °C (+14 °F to +122 °F) 
Storage temperature-20 °C to +60 °C (-4 °F to +140 °F)-20 °C to +60 °C (-4 °F to +140 °F) 
Relative humidity10 °C to 30 °C, 95 % RH non-condensing10 °C to 30 °C, 95 % RH non-condensing 
Water and dust resistantIP 51, dust & drip proofIP 51, dust & drip proof 
Weight (Including batteries)2.1 kg (4.6 lbs)2.1 kg (4.6 lbs) 
Size (H x W x D)265 x 190 x 70 mm (10.4 x 7.5 x 2.8 in)265 x 190 x 70 mm (10.4 x 7.5 x 2.8 in) 
Warranty3 years3 years 
Battery typeLi-ionLi-ion 
Battery operating time4 hours4 hours 
Battery re-charge time8 hours8 hours 
Battery power saving functionsAuto power down with adjustable time. On screen battery indicatorAuto power down with adjustable time. On screen battery indicator 
Line powerCountry-specific line voltage adapter / battery charger includedCountry-specific line voltage adapter / battery charger included