Fluke CV301 ClirVu® 75 mm (3 in) Infrared Window

  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 23.19ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • Fluke 075 CLKT IR Window for Outdoor and Indoor Applications
  • Fluke CV301 ClirVu® 75 mm (3 in) Infrared Window
  • Fluke CV301 ClirVu® 75 mm (3 in) Infrared Window
  • Fluke CV301 ClirVu® 75 mm (3 in) Infrared Window

Key features

Installs and grounds in less than 5 minutes

Save time with quick and easy installation with the CV Series – 5 minutes or less .

  • One technician
  • One hole with standard Greenlee® punch
  • Panel door does not need to be removed
  • Grounds instantly to metal enclosure with patent-pending AutoGround™ process
  • Maintains panel arc test ratings up to 63kA when properly installed

Work more efficiently with Fluke ClirVu® CV301 75 mm (3 in) Infrared Windows

  • NFPA 70E processes significantly reduced due to less work permit requirements
  • Faster and more comfortable inspections because full PPE is often not required
  • Reduce the risk of arc-flash and electrocution, increase the safety of your personnel and reduce the time and cost of preventive maintenance
  • CV301 is Torture Tested™ to the highest arc blast test ratings IEEE C37.20.7: 63 kA Arc tested at KEMA, IEC60529-1: IP67, IEC 60068, NEMA 4/12, CSA C22.2 NO. 14-13:2012, and CE
  • Convenience of both quick turn or security keyed access

Product overview: Fluke CV301 ClirVu® 75 mm (3 in) Infrared Window

A company's greatest investment is not the equipment that's behind the panel door; top priority is to offer the ultimate protection for the electricians, engineers and inspectors who risk their lives every day doing their jobs.

The ClirVu® coating - exclusive to Fluke infrared windows - seals the optic prior to assembly to protect against moisture degradation making it perfect for very hot and very cold environments.

Each Fluke infrared window is delivered with an identification plate attached for unique, on-site numbering for rapid location confirmation and faster repairs.

If you don't need a security key access option see the  CV300 IR Window .

The CV Series of infrared windows are also available in  50 mm (2 in) and 95 mm (4 in)  sizes.

Specifications: Fluke CV301 ClirVu® 75 mm (3 in) Infrared Window

General Specifications
Size75 mm (3 in)
Voltage rangeAny
NEMA environment typeType 4/12 (indoor/outdoor)
AutoGround™Yes
ClirVu® opticYes
Operating temperature-40°C to +232°C (-40° F to +450°F) and +260°C (500°F) intermittent
Compatible with all Fluke camerasYes
Jam nut locking systemYes
Cover and fastener permanently attachedYes
Single-hole installYes
Hand turn and security key door latch optionsYes
Visual inspection and fusion capableYes
Short/Mid/Long-wave IR and UV capableYes
Ratings and Testing
Arc-tested (IEEE C37.20.7)63 kA for 30 cycles @ 60 Hz at KEMA
CSA C22.2 No.Yes
CSA type ratingType 4
IP ratingIP67 at TUV
Lloyds registerUp to 11 kV marine switchgear, indoor or outdoor (offshore only)
Vibration ratingIEC60068-2-6 at TUV
Humidity ratingIEC60068-2-3 at TUV
Install
Actual mounting hole diameter required89.89 mm (3.539 in)
Greenlee® punch kit = punch/die739BB = 1431AV/1432AV
Recommended max panel thickness10 gage
Overall window height141.5 mm (5.57 in)
Overall window width111.5 mm (4.39 in)
Overall window thickness16.2 mm (0.64 in)
Door latchSecurity Key
Optics
Optic insert diameter75 mm (2.96 in)
Viewing aperture diameter67.95 mm (2.675 in)
Viewing aperture area3626 mm2 (5.62 in2)
Thickness2 mm (0.08 in)
Other
WarrantyLifetime replacement against manufacturing defects

Models: Fluke CV301 ClirVu® 75 mm (3 in) Infrared Window

Fluke CV301
Fluke CV301 ClirVu® 75 mm (3 in) Infrared Window

Find a distributor

Includes:

  • 3 in (75 mm) IR Window
  • Security key door latch
  • Warranty statement 
  • Fluke IR Windows are complete, assembled and ready for installation
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 21.54ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 24.38ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Please enable cookies to view product reviews.