Fluke Ti480U Ti401U Ti300U Infrared Thermal Cameras
Key features
- It is equipped with a robust sensor and optical system that delivers enhanced image sharpness to capture a clear image for better quality image presentation
- UltraFocus focusing technology: effective focus algorithm in one second, laser distance autofocus, and continuous auto focus function makes inspection work easier and more efficient
- Up to 30Hz frame rate to support smooth video recording for moving objects
- Temperature measurement range up to 1200 °C to cover higher process requirements and R&D applications
- Support up to 10x digital zoom for easy screen zooming and checking of long-distance targets such as high voltage equipment, overhead pipelines, and large mechanical equipment
- SmartView IR software for PC to process thermal images and videos, analyze measurement data, and generate reports
- Classic Fluke industrial design: Ergonomic and rugged design for single-hand operation in industrial environment
Product overview: Fluke Ti480U Ti401U Ti300U Infrared Thermal Cameras
The NEW Fluke Ultra Series Thermal Cameras is designed to provide advanced visual infrared experience. It comes with a smart intuitive user interface, increased thermal sensitivity to capture the smallest differences and the latest technology for on-screen clarity. A professional 640 x 480 Infrared Camera with improved spatial resolution and UltraFocus focusing technology makes the Ti480U/401U/300U go-to camera range for the professional moving to the next level.
Specifications: Fluke Ti480U Ti401U Ti300U Infrared Thermal Cameras
Function Parameter | Fluke Ti480u | Fluke Ti401u | Fluke Ti300u |
Basic Parameters | |||
IR resolution | 640 × 480 | 640 × 480 | 384 × 288 |
SuperResolution | 1280 × 960 | - | - |
Detector type | Uncooled focal plane infrared detector | ||
Thermal sensitivity (NETD) @ 30 °C | 50 mk (0.05 °C) | 75 mk (0.075 °C) | 75 mk (0.075 °C) |
Spectral response | 7 to 14 μm | ||
Image frame rate | 30 Hz | 30 Hz | 30 Hz |
Lens Field of View (FOV) | 25° x 19° | ||
Spatial resolution (IFOV) | 0.68 mrad | 0.68 mrad | 1.14 mrad |
Minimum imaging distance | 0.25 m | 0.1 m | |
Lens focal distance | f 24.8 | f 15 | |
Focus | Auto / Manual Focus | ||
Lens recognition | Auto | ||
Optional lens | 2x telephoto lens | ||
4x telephoto lens | |||
Wide-angle lens | |||
Digital Zoom | 1-10x | 1-10x | 1-4x |
Measurement Analysis | |||
Temperature range | -20 °C to 1200 °C | -20 °C to 650 °C | |
Temperature measurement range | -20 °C to 120 °C | -20 °C to 120 °C | |
0 °C to 650 °C | 0 °C to 650 °C | ||
300 °C to 1200 °C | |||
Intelligent range | Yes | Yes | Yes |
Temperature accuracy | ±2 °C or 2%, whichever is greater (@ 23 °C ± 5 °C ambient temperature) | ||
Temperature measurement area | Spots: 16 | ||
Lines: 8 | |||
Areas: 12 | |||
Global temperature measurement correction | Support emissivity, environment temperature, reflected temperature, relative humidity, temperature measurement distance, IR window (temperature and transmittance) correction | ||
Area temperature measurement correction | Yes | ||
Area audible alarm | Support high and low temperature alarm for the highest, lowest and average temperature of the area | ||
Temperature rise function | Reference temperature can be the highest, lowest, or custom temperature of the area | ||
On-Imager analysis | The thermal photos or videos are directly analyzed in the Imager | ||
Analysis software for PC | SmartView IR | ||
Image Display | |||
Display Screen | 3.5" LCD, 640 × 480 | ||
Image mode | Thermal image, Visible image, PIP, Fusion | ||
Palettes | Grey, Iron 10, IronRed, Rainbow, Grey10, GreyRed, MidGrey, Yellow and Rain | ||
Palettes can be inverted | |||
Support real-time palette preview and switching | |||
Temperature span mode | Support automatic adjustment of temperature span (min. 3 °C) | ||
Support manual adjustment of temperature span (min. 2 °C) | |||
The maximum and minimum value of temperature span can be selected by touch (min. 2 °C) | |||
Color and audible alarm | Yes. Above the temperature, below the temperature and between the temperature | ||
Information displayed on the image | Display the global maximum, minimum, average temperature and temperature measurement parameters | ||
High/low temperature tracking | Marking and automatically tracks high and low temperature points | ||
IR-Fusion | |||
Blending degree of a visual photo and an infrared thermal image | 0% to 100% | ||
Picture-in-Picture (PIP) | Yes. The size, position and blending degree of infrared window can be adjusted | ||
Shooting Function | |||
Digital camera | Industrial grade digital camera with 13-megapixel lens | ||
Memory card | Micro SD card, standard 32 GB; expandable to 64 GB, 128 GB | ||
Shooting Mode | Support single frame and time-lapse shooting | ||
Image format | .bmp .jpg | ||
Screen freeze | Support single frame shooting and fully-radiometric video recording | Support single frame shooting | Support single frame shooting and fully-radiometric video recording |
Code scanning function | Yes. A QR code can be scanned as a label | ||
Annotation function | Support voice, text and label annotation | ||
Fully-radiometric video recording | Support thermal video recording for analysis | Support thermal video recording for analysis | |
Non-fully-radiometric video recording | Support thermal video, visible video recording (only for viewing, not for analysis) | Support thermal video, visible video recording (only for viewing, not for analysis) | |
Video frame rate | 1 Hz to 9/16 Hz | 1 Hz to 9/16 Hz | |
Video Format | .is5, .mp4 | .is5, .mp4 | |
Gallery | Support viewing, editing and deleting captured images and video files | ||
Data Connection | |||
Bluetooth connection | Support BT4.2 LE | ||
USB interface | Type-A, USB 2.0 | ||
HDMI interface | Mini HDMI interface, HDMI 1.4 | ||
Fully-radiometric video analysis via PC software | Yes | - | Yes |
Remote display via software | Yes | - | Yes |
Remote operation via software | Yes | - | Yes |
HDMI output | Support connection to a display or a projector via the HDMI interface | ||
Ancillary Function | |||
Laser | Yes | ||
Temperature feature measurement | Support measuring the length of the temperature measurement line; support measuring the rectangular and circular area of the temperature measurement area | ||
LED torch/flashlight | Support flashlight and flash mode | ||
Power System | |||
Battery type | 7.2V, 19Whr lithium battery, replaceable and rechargeable on field | ||
Battery life | 2 to 3 hours/battery (*Actual life depends on settings and usage) | ||
Charge Mode | 10-15 V DC charging | ||
Charging time | 2.5 hours to full charge | ||
Energy saving management | Auto screen-off | ||
Battery charge | Ti SBC3B Two Bay Battery Charger (100 V ac to 240 V ac, 50/60 Hz, included), or in-Imager charging. Optional 12 V automotive charging adapter. | ||
External power supply | Power adapter (110 to 220 V, 50/60 Hz AC power) | ||
Reliability and Certification | |||
Safety standard | IEC 61010-1: pollution degree 2 | ||
Electromagnetic Compatibility (EMC) | International: IEC 61326-1: Industrial Electromagnetic Environment; CISPR 11: Group 1, Class A Korea (KCC): Class A Equipment (Industrial Broadcasting & Communication Equipment) | ||
Radio frequency | 2400 MHz to 2483.5 MHz | ||
Radio output power | <100 mW | ||
Laser | IEC 60825-1, Class 2; 650 nm; <1 mW | ||
Ingress protection rating | IEC 60529: IP52 | ||
Drop test | Designed for 1 m drop resistance | ||
Physical Parameter | |||
Operating temperature | -10 °C to 50 °C | ||
Storage temperature | -20 °C to 50 °C, without battery | ||
Relative humidity | 0% to 95% (non-condensing) | ||
Dimensions | 27.9 cm x 12.2 cm x 17.5 cm | ||
Weight | 1215 g | 1188 g | |
Warranty and Maintenance | |||
Warranty | 2 years | ||
Recommended calibration period | 2 years | ||
Supported Languages | |||
Supported languages | Simplified Chinese, English, Japanese, Korean, Traditional Chinese | ||
Optional Lenses | |||
Lens name | Field of view | Minimum imaging distance | |
Standard lens | 25° x 19° | 0.1 m (Ti300U),0.25 m (Ti480/401U) | |
Wide-angle lens | 44° x 34° | 0.1 m | |
2x telephoto lens | 12° x 9° | 1.0 m (Ti480U/401U), 0.25 m (Ti300U) | |
4x telephoto lens | 7° x 5° | 3.0 m (Ti480U/401U), 1 m (Ti300U) |
Models: Fluke Ti480U Ti401U Ti300U Infrared Thermal Cameras
Fluke Ti480U
Model: Fluke Ti480U Thermal Imagers
Fluke Ti480U
Thermal Imagers
- Fluke Ti480U Thermal Imager
- Charger
- Battery
- Hard carrying case
- HDMI cable
- USB cable
- Safety information
- Report
Fluke Ti401U
Model: Fluke Ti401U Thermal Imagers
Fluke Ti401U
Thermal Imagers
- Fluke Ti401U Thermal Imager
- Charger
- Battery
- Carrying case
- HDMI cable
- USB cable
- Safety information
- Report
Fluke Ti300U
Model: Fluke Ti300U Thermal Imagers
Fluke Ti300U
Thermal Imagers
- Fluke Ti300U Thermal Imager
- Charger
- Battery
- Carrying case
- HDMI cable
- USB cable
- Safety information
- Report