Fluke 77 IV Digital Multimeter

Fluke 77 IV Digital Multimeter is rated 4.8 out of 5 by 23.
  • y_2024, m_10, d_30, h_8
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_1, tr_22
  • loc_en_US, sid_3739292270644, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 22.67ms
  • REVIEWS, PRODUCT
  • Fluke 77 IV Digital Multimeter 1
  • Fluke 77 IV Digital Multimeter

Key features

  • Large display
  • Backlight for work in dim areas
  • Min / Max to record signal fluctuations
  • Ergonomic overmolded housing with integrated probe holders
  • Free your hands with the optional TPAK magnetic hanger
  • Auto and Manual ranging
  • Meets Measurement Category 1000 V CAT III and Category IV 600 V safety standards

The 77 IV replaces the 77. Move up to superior utility and safety today.

Product overview: Fluke 77 IV Digital Multimeter

Versatile meters for field service or bench repair.

The Fluke 77 IV digital multimeter has the features needed to repair most electrical and electronic problems. This meter is simple to use and has significant improvements over Fluke's original 70 Series with more measurement functions, conformance to the latest safety standards, and a much larger display that's easier to view.

It measures:

  • Wide 1000 V measurement range
  • Average responding AC measurements
  • 0.3% accuracy
  • 10 Amps continuous (20 A for 30 seconds)
  • Frequency and capacitance
  • Resistance and continuity

What's in the box:

  • Fluke 77 IV Digital Multimeter
  • (1 pair) Test leads
  • 9V Battery (Installed)
  • Quick reference guide

Specifications: Fluke 77 IV Digital Multimeter

Specifications
Voltage DCRange6.000 V – 1000 V
Best accuracy±(0.3% + 1)
Best resolution0.1 mV
Voltage ACRange600.0 mV – 1000V
Best accuracy±(2.0% + 2)
Best resolution1.0 mV
Amps ACRange60.00 mA – 10 A
Best accuracy2.5% + 2
Best resolution0.01 mA
Amps DCRange60.00 mA – 10A
Best accuracy1.5% + 2
Best resolution0.01 mA
ResistanceRange600.0 Ω – 50 MΩ
Best accuracy±(0.5% + 1)
Best resolution0.1 Ω
CapacitanceRange1nF – 9,999 μF
Best accuracy±(1.2% + 2)
Best resolution1 nF
FrequencyRange99.99Hz – 99.99kHz
Best accuracy±(0.1% + 1)
Best resolution0.01 Hz
SafetyANSI / ISA S82.02.01, CSA C22.2–1010.1, IEC 61010 to 1000 V Measurement Category III, 600 V Measurement Category IV
CertificationsCSA, TÜV (EN61010), Π, (N10140)
General Specifications
Maximum voltage between any terminal and earth ground1000 V
Surge protection8 kV peak per IEC 61010
Ω Fuse for mA inputs440 mA, 1000 V FAST Fuse
Ω Fuse for A inputs11 A, 1000 V FAST Fuse
DisplayDigital6000 counts, updates 4/sec
Bar graph33 segments, updates 32/sec
Frequency10,000 counts
Capacitance1,000 counts
AltitudeOperating2,000 meters
Storage12,000 meters
TemperatureOperating-10°C to + 50°C
Storage-40°C to + 60°C
Temperature coefficient0.1 x (specified accuracy / °C (< 18°C or > 28°C)
Electromagnetic compatibility
(EN 61326–1:1997)
In an RF field of 3 V/M, accuracy = specified accuracy except in temperature:
specified accuracy ±5°C (9°F)
Relative humidity
(maximum non-condensing)
90% to 35°C
75% to 40°C
45% to 50°C
Battery life400 hours typical (alkaline)
Size (H x W x L)4.3 x 9 x 18.5 cm
Weight420 g

Models: Fluke 77 IV Digital Multimeter

Fluke 77 IV
Fluke 77 IV Digital Multimeter

Find a distributor

Includes:

  • Installed 9V battery
  • Test leads
  • Users manual

Hello, What is the input impedance of the 77 when measuring DC voltage?

Asked by: Marty T
The Fluke 77 IV Digital Multimeter's input impedance for DC volts is 10 megohms.
Answered by: FlukeCorporation
Date published: 2023-10-26

Is the 77 IV a true RMS multimeter?

Asked by: fabs1
  • y_2024, m_10, d_29, h_5CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_2
  • loc_en_US, sid_3739292270644, prod, sort_[SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 22.09ms
  • QUESTIONS, PRODUCT
Rated 5 out of 5 by from Best DVM I have used ever I got the DVM back in the late 1980s/early 1990s. When I got it, I was in Electronic Circuit Design. Because of a career change to Computer Software Development, I use the meter now at home. It is my goto meter to testing anything electronic/electric. That means that the battery is now nearly/over 30 years old and I have never had to replace it. That is a great product; BTW, below it asks how long I have had it. "1 year or longer" is the max entry. I laughed. They should have have entries like 5 years, 10 years, 25 years, more than 25 years.
Date published: 2020-07-29
Rated 5 out of 5 by from Tough, reliable. I worked in the Boeing Calibration lab and would see literally hundreds of these and typically about all I had to do was change batteries and fuses. Issued by toolrooms for production use, sometimes factory, sometimes flightlie. They got torture tested. Under any normal circumstances these are virtually indestructible..
Date published: 2019-12-27
Rated 5 out of 5 by from Tough, reliable. I worked in the Boeing Calibration lab and would see literally hundreds of these and typically about all I had to do was change batteries and fuses. Issued by toolrooms for production use, sometimes factory, sometimes flightlie. They got torture tested. Under any normal circumstances these are virtually indestructible..
Date published: 2019-12-27
Rated 5 out of 5 by from Highest Quality, unreal longevity So I worked at Fluke as a designer in the 80's and brought home a 77 prototype. I moved on to another company in '85 but have kept that DVM since. It's been dropped many times and I've gone through I think 3 or 4 9v batteries and it's still going strong after 35 years. Fluke had a robust qualification process that included temperature, humidity, shock, EMI and vibration abuses. When it's time I'll upgrade to another Fluke but I think this one will outlive me.
Date published: 2018-09-30
Rated 1 out of 5 by from Auto OFF SUCKS! You have both hands involved in what you are doing, look at the meter to start adjusting, and it shuts it self off! You loose your set up as you need to move a hand, NEVER WILL I BUY A FLUKE AGAIN!
Date published: 2018-07-20
Rated 5 out of 5 by from Versatile This is the perfect volt-ohmmeter for work or home.
Date published: 2016-12-12
Rated 5 out of 5 by from Great features I have been useing the 77IV for aver secen years and it has never failed on me. I recommend anyone looking for a good tool to get this one. This mulitmeter has handeled many wiring jobs on various diesel trucks without fault.
Date published: 2016-12-09
Rated 5 out of 5 by from Solid meter with great performance. Bought this meter about 6-8 months ago and haven't had any issues. Replaced my old 77 series with this and the newer version is a definite upgrade as it should be. It's voltage range suits well for plc, electronics, and automated service circuit systems troubleshooting. Well suited for field technicians and mechanics alike. Fluke does not disappoint with its rugged package And true test to the elements. I have other meters And nothing is as reliable as my Fluke.
Date published: 2016-12-09
  • y_2024, m_10, d_30, h_8
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_1, tr_22
  • loc_en_US, sid_3739292270644, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 22.63ms
  • REVIEWS, PRODUCT
Please enable cookies to view product reviews.