7526A Precision Process Calibrator

  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 22.12ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;

Key features

Read more

Product overview: 7526A Precision Process Calibrator

Priority Gold Instrument CarePlan

Make sure to ask your account manager about the Fluke Calibration Priority Gold CarePlan

A Fluke Calibration Priority Gold CarePlan puts you in control of your downtime and in control of your business, with calibration services and other offerings.

Video Player is loading.
Current Time 0:00
Duration 0:00
Loaded: 0%
Stream Type LIVE
Remaining Time 0:00
 
1x
    • Chapters
    • descriptions off, selected
    • subtitles off, selected

      Learn more

      A “best fit” for your process calibration requirements


      “Doing more with less” is a requirement every process manufacturer faces today. To maintain product quality, reduce waste, improve efficiency and conform to regulatory standards, instruments that measure process variables such as temperature and pressure must be calibrated at regular intervals. Selecting the right calibrator for the job, however, can be tricky—especially when attempting to balance precision and versatility with cost. Less expensive than high-end multi-product calibrators, yet more precise and versatile than handheld field calibrators, the 7526A is a “best fit” for instrument shops that value precision, versatility and economy.

      Intuitive user interface


      The user interface includes cursor controls, function keys and a ten-key keypad, making it easy to navigate through intuitive menus; store and recall up to nine setpoints for each input/output parameter; enter RTD or SPRT coefficients; and easily change display units with a key press. With two LCD displays, you can easily view both source and measurement results simultaneously.

      Increase efficiency through automation


      For increased efficiency and calibration throughput, or to operate an automated test system (ATE), combine the 7526A with MET/CAL® Plus Calibration Management Software. MET/CAL Plus is a powerful application for creating, editing and testing calibration procedures and collecting and reporting results on a wide variety of instruments. It includes MET/CAL® software– the industry leading software for automated calibration, and MET/TEAM™ Express–a dedicated system to manage your test and measurement assets. Or choose MET/TEAM™ standard edition for fully-featured enterprise calibration asset management, with optional modules for on-site calibration, commerce management, and customer web portal. The 7526A standard computer interface includes RS-232 and GPIB (IEEE-488). A USB-to-serial adapter cable is also included with the calibrator as standard.

      Don’t forget the sensor


      Calibrating the electronics portion of a temperature transmitter is only a part of a complete calibration. You also need to calibrate the temperature sensor itself, whether an RTD or thermocouple. Ignoring the sensor can be a mistake, because temperature sensors are responsible for more than 75% of the output errors in temperature transmitters. You can calibrate the temperature sensor individually, or calibrate both the sensor and the transmitter as a system using a dry-block calibrator such as the Fluke Calibration 914X Series Field Metrology Wells. The Field Metrology Wells were designed specifically with process calibration in mind—optimizing speed to temperature, portability, stability and accuracy. The 7526A and a 914X dry-block calibrator make a perfect combination for calibrating just about any temperature transmitter.

      Source as well as measure pressure


      The P5500 series of comparison test pumps can be used with the 7526A and Fluke 700P and 750P series pressure modules to generate or control test pressures. The unique test port configuration allows for easy, tool-free connections of a wide variety of connection sizes and types, including NPT, BSP, and metric threads. The P5510 includes a built-in hand pump to generate vacuum or positive pressure up to 300 psi (2 MPa). The P5513 allows for precise control of pneumatic pressures up to 3000 psi (20 MPa). An external pressure supply is required. The P5514 allows for generation of hydraulic pressures up to 10 000 psi (70 MPa). The P5515 includes a built-in priming pump and screw pump that allows for pressure generation up to 20 000 psi (140 MPa). Both the P5514 and P5515 can be used with oil or water. Special versions are available with ethylene propylene seals for use with more aggressive fluids.

      Specifications: 7526A Precision Process Calibrator

      DC voltage, output
      Range [1]Absolute Uncertainty, ±
      (ppm of output + μV), 1-yr
      Resolution
      0 to 100 mV3031 μV
      0 to 1 V301010 μV
      0 to 10 V30100100 μV
      0 to 100 V301 mV1 mV
      TC Output and Input
      –10 mV to 75 mV302 μV1 μV

      [1] All outputs are positive only unless otherwise noted

      DC voltage, isolated input
      RangeAbsolute Uncertainty, ±
      (ppm of reading + mV),
      1-yr
      Resolution
      0 to 10 V1000.2100 μV
      10 V to 100 V1002.01 mV
      DC Current, output
      Range[1]Absolute Uncertainty,
      ± (ppm of reading + μA),
      1-yr
      Resolution
      0 to 100 mA5011 μA

      [1] For line voltages less than 95 V, ±100 ppm of reading

      DC current, isolated input
      RangeAbsolute Uncertainty, ±
      (ppm of reading + μA),
      1-yr
      Resolution
      0 mA to 50 mA10010.1 μA
      0 mA to 24 mA [1][2]
      (Loop Power)
      10010.1 μA

      [1] Loop Power: 24 V ±10%
      [2] HART Resistor: 250 Ω ± 3%

      Resistance, output
      RangeAbsolute
      Uncertainty,
      tcal ± 5 °C, ±
      Ohms, 1-yr
      ResolutionNominal
      current
      5 Ω to 400 Ω0.0150.001 Ω1 to 3 mA
      5 Ω to 4 kΩ0.30.01 Ω100 μA to 1 mA
      Resistance, input
      RangeAbsolute Uncertainty, ±
      (ppm of reading + Ω), 1-yr
      Resolution
      0 Ω to 400 Ω200.0040.001 Ω
      0 Ω to 4 kΩ200.040.01 Ω
      Sample thermocouple accuracy, input/output
      (does not include all available TC types)[1]
      TC typeTemperature Range (°C)Absolute Uncertainty,
      tcal ±5 °C, ± (°C), 1-yr [2]
      MinMax
      J-21012000.09
      K-25013720.1
      S-5017670.29
      T-2504000.11

      [1] See extended specifications for all TC types (B,C,E,J,K,L,N,R,S,T,U,XK,BP)
      [2] Best accuracy within specified TC temperature range

      Sample RTD and thermistor, output
      (does not include all available RTD types)[1]
      RTD TypeTemperature Range (°C)Absolute Uncertainty,
      tcal ±5 °C, ± (°C), 1-yr
      MinMax
      Pt 385, 100 Ω-2008000.05
      YSI 40015500.007

      [1] See extended specifications for all RTD types: Pt-100 (385, 3926, 3916), Pt- 200, Pt-500, Pt-1000, Ni-120, Cu-427, SPRT

      Sample RTD and thermistor, intput
      (does not include all available RTD types)[1]
      RTD TypeTemperature Range (°C)Absolute Uncertainty,
      tcal ±5 °C, ± (°C), 1-yr
      MinMax
      Pt 385, 100 Ω–801000.020
      1003000.024
      3008000.038
      YSI 40015500.007

      [1] See extended specifications for all RTD types: Pt-100 (385, 3926, 3916), Pt- 200, Pt-500, Pt-1000, Ni-120, Cu-427, SPRT

      General specifications
      Standard interfaceRS-232, IEEE-488 (GPIB)
      Temperature
      performance
      Operating:0 °C to 50 °C
      Calibration (tcal):18 °C to 28 °C
      Storage:–20 °C to 70 °C
      Electromagnetic
      compatibility
      CE: Conforms to EN61326;
      operation in controlled EM environments
      Temperature coefficientTemperature coefficient for temperatures
      outside tcal 5 °C is 10% of the 90-day
      specification (or 1 year if applicable) per °C
      Relative humidityOperating:<80% to 30 °C
      <70% to 40 °C
      <40% to 50 °C
      AltitudeOperating:3,000 m (9,800 ft) max
      Non-operating:12,200 m (40,000 ft) max
      SafetyEN/IEC 61010-1:2010 3rd Edition,
      UL 61010-1:2012, CAN/CSA 22.2 No. 61010-1-12
      Analog low isolation20 V
      Line power120 V~:100 V to 120 V
      240 V~:220 V to 240 V
      Line frequency47 Hz to 63 Hz
      Line voltage variation± 10 % about setting
      Power consumption15 VA maximum
      DimensionsHeight:14.6 cm (5.75 in)
      Width:44.5 cm (17.5 in)
      Depth:29.8 cm (11.75 in)
      Weight
      (without options)
      4.24 kg (9.35 lb)

      Models: 7526A Precision Process Calibrator

      7526A
      Precision Process Calibrator

      Find a distributor
      Includes traceable calibration report, user manual CD, getting started guide, power cord, thermocouple shorting jumper and USB-to-serial adapter cable.