Fluke i30 AC/DC Current Clamp
Fluke i30 AC/DC Current Clamp is rated out of 5 by 1.
Key features
- Current clamp based on Hall Effect technology that measures both DC and AC current
- Includes banana plug end for compatibility with multimeters
- Current range: 30 mA to 30 A DC, 30 mA to 20 A AC rms
- Frequency range: DC to 20 kHz (-0.5 dB)
- CAT III 300 V safety rating
Product overview: Fluke i30 AC/DC Current Clamp
The i30 current clamp is based on Hall Effect technology for use in measurement of both DC and AC current. The i30 may be used in conjunction with multimeters, recorders and other suitable recording instruments for accurate non-intrusive current measurement.
Specifications: Fluke i30 AC/DC Current Clamp
Electrical Specifications | |
Specified current range | 30 mA to 30 A DC, 30 mA to 20 A AC rms |
Usable current range | 5 mA to 30 A DC, 30 mA to 20 A AC rms |
Crest Factor | 1.4 in |
Output sensitivity | 100 mV/A |
Accuracy (at +25°C) | DC ±1 % of reading ±2 mA AC ± 0.5 dB of reading ±2 mA |
Resolution | ±1 mA |
Load impedance | > 10 k Ohms and ≤ 100pF |
Conductor position sensitivity | ±1% relative to center reading |
Frequency range | DC to 20 kHz (-0.5 dB) |
Temperature coefficient | ±0.01% of reading/°C |
Power supply | 9 V Alkaline, MN1604/PP3, 30 hours, low battery indicator |
Working voltage (see Safety Standards section) | 300 V AC rms or DC |
General Specifications | |
Maximum conductor size | 19 mm diameter |
Output connection | 4 mm safety connector |
Output zero | Manual adjust via thumbwheel |
Cable length | 1.5 meters |
Operating temperature range | 0°C to +50°C |
Storage temperature range (with battery removed) | -20°C to +85°C |
Operating humidity | 15% to 85% (non-condensing) |
Weight | 250 g |
Safety | IEC 61010-1, Pollution Degree 2 |
IEC 61010-2- 032: CAT III 300V | |
Use of the probe on uninsulated conductors is limited to 300 V ac rms or dc andfrequencies below 1 kHz. | |
EMC Compatibility | IEC 61326-1: Portable Electromagnetic Environment |
Models: Fluke i30 AC/DC Current Clamp
Fluke i30
AC/DC Current Clamp
Rated 4 out of 5 by coenen5627 from i30 Suited from DC to 100 kHz The i30 clamp-on current probe is well suited from DC up to 100 kHz. Unfortunately, the current-to-voltage transfer function increases again at higher frequencies due to capacitive coupling to the metal core of the clamp. Grounding this metal improved also the noise coupled into the clamp when laying next to an interference source
Date published: 2013-10-14