Portable Datenerfassung der Hydra-Serie
Nicht mehr hergestellt
Dieses Produkt wird nicht mehr hergestellt oder wurde neu klassifiziert.
Fluke empfiehlt:1586A Super-DAQ Temperaturscanner mit hoher Genauigkeit
Produktübersicht: Portable Datenerfassung der Hydra-Serie
Technische Daten: Portable Datenerfassung der Hydra-Serie
Technical data | |
DC voltage | Area: 90 mV to 300/25% Volt Resolution: 1 µV to 10 mV Accuracy: (3 sigma) ± 0.018 % |
AC voltage | Area: 90 mV to 300/25% Volt Resolution: 1 µV to 10 mV Accuracy: (3 sigma) ± 0.018 % |
Resistance | Area: 300 Ω to 10 MΩ Resolution: 10 mΩ to 1 kΩ Accuracy: (3 sigma) ± 0.013 % |
frequency | Area: 15 Hz to 1 MHz Resolution: 0.01 Hz to 1 kHz Accuracy: (3 sigma) ± 0.05 % |
RTD (Pt100) | Area: -200 to 600 °C Resolution: 0.02°C Accuracy: (3 sigma) ± 0.05 °C |
J-thermocouples | Area: -100 to 760 °C Resolution: 0.1°C Accuracy: (3 sigma) ± 0.39 °C |
K-thermocouples | Area: -100 to 1372 °C Resolution: 0.1°C Accuracy: (3 sigma) ± 0.45 °C |
T-thermocouples | Area: -25%·up to 400 °C Resolution: 0.1°C Accuracy: (3 sigma) ± 0.39 °C |
Other thermocouple types | R, S, B, C, E, N |
Technical specifications of the 2625A data storage device | |
2625A Data storage | Stores 2047 scans; along with each scan, the following information is stored: timestamp, all defined analog input channels, the status of four alarm outputs and eight digital I/Os, and the count value of the adder function |
Scan content | Memory life: at least 5 years; at 25 °C Date and time stamp Values for all defined analog input channels Status of four alarm outputs and eight digital I/O Count value of the adder function |
Technical data of the 2635A memory card capacity | |
1MB card | 4 channels in scan: 36,860 10 channels in scan: 19,860 20 channels in scan: 11,210 |
4MB card | 4 channels in scan: 149,039 10 channels in scan: 80,251 20 channels in scan: 45,359 |
General specifications | |
Channel performance | Analog inputs: 21; digital I/O and alarm outputs Adder function: 1 |
Power supply, battery life | 90 V AC to 264 V AC (50 Hz or 60 Hz) or 9 V DC to 16 V DC; less than 10 W. (If both sources are applied simultaneously, the higher of AC or DC is used. 120 V AC corresponds to ~14.5 V DC.) |
Temperature, humidity (non-condensing) | Operation: 0 °C to 28 °C, <=90 % rel. humidity; 28 °C to 40 °C, <=75 % rel. humidity; 40 °C to 60 °C, <=50 % rel. humidity; Storage: -40 °C to 75 °C, 5 % to 95 % rel. humidity |
Height | Operation: 3050m; Storage: 12,200m |
Common mode and differential mode voltage | 300 V DC or AC RMS (channels 0,1,11); 25% Volts DC or AC RMS (all other channels) IEC overvoltage category II. |
insulation | Analog input to analog input and analog input to any digital input:Conforms to IEC 1010 for 300/25% volt reinforced insulation and ANSI/ISA-S82.01-1988 and CSA 231 for 250 volt simple insulation |
Security | Conforms to applicable parts of IEC1010, ANSI/ISA-S82.01-1988, CSA231, UL 1244, CSA 556B, CE. |
RF emissions | Complies with FCC EMI Class A Equipment and VDE 0871B |
Dimensions | 9.3cm x 21.6cm x 31.2cm |
Weight | 2.95kg |
Memory lifespan | 10 years for real-time clock, facility configuration and measurement data in 2625A, memory cards 5 years for the 256 KB card |
Interfaces | RS-232C connector: nine-pin, male (DB-9P) |
Signals | TX, RX, DTR, GND |
Modem control | Full duplex |
Baud rates (setting via the front panel) | 300, 600, 1200, 2400, 4800, 9600, 19,200, 38,400 |
Echo (setting via the front panel) | On/Off |
Flow Control | XON/XOFF |
IEEE-488 (optional, 2620A only) | Complies with IEEE-488.1 standard; when used, the RS-232C interface is disabled |
Modelle: Portable Datenerfassung der Hydra-Serie
2620A
Hydra-Datenerfassungseinheit
2620A/05
Hydra-Datenerfassungseinheit mit IEEE-488-Schnittstelle
2625A
Hydra-Datenlogger
2635A/C
Hydra Data Bucket (1-MB-Speicherkarte)
2635A/C-4MB
Hydra Data Bucket (4-MB-Speicherkarte)
Handbücher und Ressourcen: Portable Datenerfassung der Hydra-Serie
- 2620A/2625A | Benutzerhandbuch
- 2620A/2625A Series II | Benutzerhandbuch
- 2635A Series II | Benutzerhandbuch
- Hydra Logger | Benutzerhandbuch
- 2620A | Erklärung zu flüchtigen Speichern
- 2620A/2625A/2635A | Service-Handbuch
- 2625A | Erklärung zu flüchtigen Speichern
- 2635A | Erklärung zu flüchtigen Speichern
- Hydra Logger | Software-Referenzhandbuch