Fluke 110 True-rms Digital Multimeter

  • Fluke 110 True-rms Digital Multimeter
  • Fluke 110 True-rms Digital Multimeter with tilt-stand
  • Fluke 110 True-rms Digital Multimeter with included equipment
  • Fluke 110 True-rms Digital Multimeter easily fits in your hand
  • Fluke 110 True-rms Digital Multimeter – fast, easy go/no-go testing
  • Video Player is loading.
    Current Time 0:00
    Duration 0:00
    Loaded: 0%
    Stream Type LIVE
    Remaining Time 0:00
     
    1x
      • Chapters
      • descriptions off, selected
      • subtitles off, selected
      1. Fluke 110 True-rms Digital Multimeter
      2. Fluke 110 True-rms Digital Multimeter with tilt-stand
      3. Fluke 110 True-rms Digital Multimeter with included equipment
      4. Fluke 110 True-rms Digital Multimeter easily fits in your hand
      5. Fluke 110 True-rms Digital Multimeter – fast, easy go/no-go testing
      6. Fluke 110 True-rms Digital Multimeter video demo

      Wichtigste Merkmale

      • True-rms ac voltage for accurate measurements on non-linear signals
      • Resistance and continuity
      • Large white LED backlight to work in poorly lit areas

      Produktübersicht: Fluke 110 True-rms Digital Multimeter

      Compact true-rms meter for accurate electrical installation and troubleshooting

      The Fluke 110 is a versatile multimeter for electrical measurements and troubleshooting. Trusted by residential and commercial electricians for troubleshooting and maintenance. The 110 is for professional use, where true-rms accuracy is needed.

      Key product capabilities

      • True-rms ac voltage for accurate measurements on non-linear signals
      • Large white LED backlight to work in poorly lit areas
      • Resistance and continuity
      • Min/Max/Average to record signal fluctuations
      • CAT III 600 V safety rated

      Technische Daten: Fluke 110 True-rms Digital Multimeter

      Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 90 %. The accuracy specifications take the form of: ± ( [ % of Reading ] + [ Counts ] )

      General specifications
      Maximum voltage (between any terminal and earth ground)600V
      SafetyIEC 61010-1, Pollution degree 2
      IEC 61010-2-033, CAT III 600 V
      DisplayDigital: 6,000 counts, updates 4/sec
      Bar graph33 segments, updates 32/sec
      Temperature
      Operating
      Storage

      -10 °C to + 50 °C
      -40 °C to + 60 °C
      Battery9 volt Alkaline, IEC 6LR61
      Battery life400 hours typical, without backlight
      Accuracy
      MeasurementRangeResolutionAccuracy ± ([% of reading] + [counts])
      DC millivolts600.0 mV0.1 mV0.5 % + 2
      DC volts6.000 V
      60.00 V
      600.0 V
      0.001 V
      0.01 V
      0.1 V
      0.5 % + 2
      Accuracy
      MeasurementRangeResolutionAccuracy ± ([% of reading] + [counts])
      AC millivolts1 true-rms600.0 mV0.1 mV1.0 % + 3 (dc, 45 Hz to 500 Hz)
      2.0 % + 3 (500 Hz to 1 kHz)
      AC volts1 true-rms6.000 V
      60.00 V
      600.0 V
      0.001 V
      0.01 V
      0.1 V
      1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz)
      Continuity600 Ω1 ΩBeeper on < 20 Ω, off> 250 Ω; detects opens or shorts of 500 μs or longer.
      Ohms600.0 Ω0.1 Ω0.9 % + 2
      6.000 kΩ
      60.00 kΩ
      600.0 kΩ
      6.000 MΩ
      0.001 kΩ
      0.01 kΩ
      0.1 kΩ
      0.001 MΩ
      0.9 % + 1
      40.00 MΩ0.01 MΩ5 % + 2

      1All ac voltage ranges are specified from 1 % to 100% of range. Because inputs below 1 % of range are not specified, it is normal for this and other true-rms meters to display non-zero readings when the test leads are disconnected from a circuit or are shorted together. For volts, crest factor of ≤ 3 at 4000 counts, decreasing linearly to 1.5 at full scale. AC volts is ac-coupled.