Fluke 113 電氣測量萬用電表

  • Fluke 113 Digital Multimeter
  • Fluke 113 Digital Multimeter
  • Fluke 113 Digital Multimeter
  • Video Player is loading.
    Current Time 0:00
    Duration 0:00
    Loaded: 0%
    Stream Type LIVE
    Remaining Time 0:00
     
    1x
      • Chapters
      • descriptions off, selected
      • subtitles off, selected
      1. Fluke 113 Digital Multimeter
      2. Fluke 113 Digital Multimeter
      3. Fluke 113 Digital Multimeter
      4. How to choose the right multimeter

      主要功能

      深入瞭解

      產品概述: Fluke 113 電氣測量萬用電表

      Fluke 113 電氣測量萬用電表可讓使用者快速輕鬆地進行基本電表設定及重新連線測試。此款電表簡單易用,具備必要的功能可維修大多數的電氣問題。Fluke 113 的功能大幅超越市面上的其他數位萬用電表 (包括 Fluke 7-600 機型)。有了 Fluke VCHEK™ LoZ 低阻抗測量功能,使用者可同時測試電壓或導通性。LoZ 低阻抗測量功能也會阻斷附近導體引起的鬼電壓。*請注意,LoZ 低阻抗測量功能會對受 RCD 保護的電路提供低負載,這可能導致 RCD 跳脫。最小/最大值功能可讓您記錄訊號波動。Fluke 113 可執行二極體測試,還提供自動和手動測距功能。此款電表符合最新安全標準,且具備讓使用者能輕鬆檢視的背光大尺寸顯示幕,是每個工具箱必備的儀表。

      規格: Fluke 113 電氣測量萬用電表

      Specifications
      VCHEK1 2 3Range6.000 V / 60.00 V / 600.0 V
      Resolution0.001 V / 0.01 V/ 0.1 V
      AccuracyDC, 45 to 500 Hz: 2.0% + 3
      500 Hz to 1 kHz: 4.0% + 3
      Diode test4Range2.000 V
      Resolution0.001 V
      Accuracy2.0% + 3
      Continuity4AccuracyBeeper on < 20 Ω, off > 250 Ω detects opens or shorts of 500 μs or longer
      Ω4Range600.0 Ω / 6.000 kΩ / 60.00 kΩ
      Resolution0.1 Ω / 0.001 kΩ / 0.01 kΩ
      Accuracy0.9% + 2 / 0.9% + 1 / 0.9% + 1
      Capacitance4Range1000 nF / 10.00 μF / 100.0 μF / 9999 μF
      Resolution1 nF / 0.01 μF / 0.1 μF / 1 μF
      Accuracy1.9% + 2
      100 μF - 1000 μF: 1.9% + 2
      1000 μF: 5% + 20
      1. All VChek voltage ranges are specified from 60 counts to 100% of range. Because inputs below 60 counts are not specified, it is possible and normal for this and other true-rms meters to display non-zero readings when the test leads are disconnected from a circuit or are shorted together.
      2. Crest factor of ≤ 3 at 4000 counts, decreasing linearly to 1.5 at full scale.
      3. Minimum measureable input in VCHEK autorange is 3 VDC. For measurements below 3 VDC, push Range button twice to get to 6 VDC manual range.
      4. After measuring voltage, a wait time of 1 minute is required to maintain accuracy of ohms, capacitance, diode test, and continuity.
      Specifications
      Maximum voltage between any terminal and earth ground600 V
      Display3 3/4-digits, 6000 counts, updates 4/sec
      Operating temperature-10°C to 50°C (14°F to 122°F)
      Storage temperature-40°C to 60°C (-22°F to 140°F)
      Temperature coefficient0.1 x (specified accuracy) / °C (< 18°C or > 28°C)
      Operating altitude2,000 m
      Storage altitude10,000 m
      Relative humidity95% to 30°C
      75% to 40°C
      45% to 50°C
      Battery type9 Volt Alkaline, IEC 6F22
      Battery lifeAlkaline: 300 hours typical, without backlight
      Size (H x W x L)167.1 x 85.1 x 46.0 mm (6.58 x 3.35 x 1.81 in)
      Weight13.0 oz (404 g)
      SafetyIEC 61010-1: Pollution Degree 2
      IEC 61010-2-033: CAT IV 600V
      EMI regulationsComplies with FCC Part 15, Class B
      Specifications
      VCHEKInput impedance (nominal)~3 kΩ < 300 pF
      VCHEKCommon mode rejection ratio
      (1 kΩ unbalanced)
      > 60 dB at DC, 50 or 60 Hz
      ΩOpen circuit test voltage< 2.7 VDC
      Full scale voltage< 0.7 VDC
      Diode testOpen circuit test voltage2.7 VDC
      Full scale voltage2.000 VDC
      ΩShort circuit current< 350 μA
      Diode testShort circuit current< 1.0 mA

      機型: Fluke 113 電氣測量萬用電表

      Fluke 113

      Fluke 113電氣測量萬用電表


      購買
      附件包括:
      • 皮製護套
      • 9 V 電池組(已安裝)
      • 測試導線組