擁有Fluke 725多功能程控儀錶校正器,您可以測試和校正幾乎所有的程控參數。它可以測量和輸出毫安培、伏特、溫度(RTD和熱電偶)、頻率、歐姆,及壓力信號(需外接可選的壓力模組)。需要校正變送器嗎?725的分割顯示幕,可同時觀察輸入和輸出。對於閥門和I/P測試,在測量壓力的同時還可以輸出mA。725具有自動步進和自動斜坡功能,可用於遠端測試,25%步進功能可用於快速線性度檢測。 當您拿到Fluke 725時,即可馬上投入工作。該儀錶控制起來非常簡單,沒有功能表,容易操作。其存儲功能使得設置更加快捷,且非常堅固。

規格: Fluke 725 Multifunction Process Calibrator

Measurement Accuracy
Voltage DC
30.000 V 0.02%+ 2 counts (upper display)
30.000 V 0.02%+ 2 counts (lower display)
100.00 mV 0.02%+ 2 counts
-10.00 mV to 75.00 mV 0.025 % + 1 count (via TC connector)
Current DC
24.000 mA 0.02%+ 2 counts
Resistance
0.0 to 400.0 Ω 0.1Ω (4-wire), 0.15Ω (2- and 3-wire)
401 to 1500 Ω 0.5Ω (4-wire), 1Ω (2- and 3-wire)
1500 to 3200 Ω 1Ω (4-wire), 1.5Ω (2- and 3-wire)
Frequency
2.0 to 1000.0 CPM 0.05 % + 1 count
1.0 to 1100.0 Hz 0.05 % + 1 count
1.00 to 10.00 kHz 0.05 % + 1 count
Sensitivity 1 V peak-to-peak-minimum
Pressure
Accuracy from 0.025% of range using any of 29 pressure modules.
 (for detailed specifications refer to pressure modules in options and accessories)
 Modules available for differential, gauge, vacuum, absolute, dual and high pressure.
Source Accuracy
Voltage DC
100.00 mV 0.02%+2 counts
10.000 V 0.02%+2 counts
-10.00 mV to 75.00 mV 0.025 % + 1 count (via TC connector)
Current DC
24.000 mA (Source) 0.02%+ 2 counts
24.000 mA (Simulate) 0.02%+ 2 counts
Resistance
15.0 to 400.0 Ω 0.15 Ω (exc. current 0.15 to 0.5 mA), 0.1 Ω (exc. current 0.5 to 2 mA)
401 to 1500 Ω 0.5 Ω(excitation current 0.05 to 0.8 mA)
1500 to 3200 Ω 1 Ω(excitation current 0.05 to 0.4 mA)
Frequency
2.0 to 1000.0 CPM 0.05%
1.0 to 1100.0 Hz 0.05%
1.00 to 10.00 kHz 0.25%
Waveform: 5 V p-p squarewave, -0.1 V offset
RTDs and Thermocouples
Measure Accuracy:
NI-120 0.2 °C
PT-100 (385) 0.33 °C
PT-100 (393) 0.3 °C
PT-100 (JIS) 0.3 °C
PT-200 (385) 0.2 °C
PT-500 (385) 0.3 °C
PT-1000 (385) 0.2 °C
Resolution: 0.1 °C
J: 0.7 °C
K: 0.8 °C
T: 0.8 °C
E: 0.7 °C
R: 1.8 °C
S: 1.5 °C
B: 1.4 °C
L: 0.7 °C
U: 0.75 °C
N: 0.9 °C
Resolution J, K, T, E, L, N, U: 0.1 °C, 0.1 °F B, R, S: 1 °C, 1 °F
XK 0.6°C
BP 1.2°C
Source Accuracy:
NI-120 0.2 °C
PT-100 (385) 0.33 °C
PT-100 (393) 0.3 °C
PT-100 (JIS) 0.3 °C
PT-200 (385) 0.2 °C
PT-500 (385) 0.3 °C
PT-1000 (385) 0.2 °C
Resolution: 0.1 °C
Note: Accuracy stated for 4-wire measurement.
J: 0.7 °C
K: 0.8 °C
T: 0.8 °C
E: 0.7 °C
R: 1.4 °C
S: 1.5 °C
B: 1.4 °C
L: 0.7 °C
U: 0.75 °C
N: 0.9 °C
Resolution J, K, T, E, L, N, U: 0.1 °C, B, R, S: 1 °C
XK 0.6°C
BP 1.2°C
Specifications
Ramp Functions
Source functions: Voltage, current, resistance, frequency, temperature
Ramps Slow ramp, Fast ramp, 25% step-ramp
Loop Power Function
Voltage: 24 V
Accuracy: 10%
Maximum current: 22 mA, short circuit protected
Step Functions
Source functions: Voltage, current, resistance, frequency, temperature
Steps 25% of range, 100% of range
Environmental Specifications
Operating Temperature
 -10 °C to +55 °C
Storage Temperature
 -20 °C to 71 °C
Operating Altitude
 3000 m
Safety Specifications
Agency Approvals
 EN 61010-1:1993, ANSI/ISA S82.01-1994; CAN/CSA C22.2 No 1010.1:1992
Mechanical & General Specifications
Size
 130 x 236 x 61 mm
Weight
 0.65 kg
Batteries
 4 AA alkaline batteries
Battery Replacement
 Separate battery compartment, accessable without breaking calibration seal
Side port connections
 Pressure module connector, also used for remote real-time programming

機型: Fluke 725 Multifunction Process Calibrator

Fluke 725
Fluke 725 Multifunction Process Calibrator

購買

Multifunction Process Calibrator including:

  • One set of AC72 alligator clips
  • One set of stackable test leads
  • One set of TL 75 testleads
  • User manuals
  • NIST- traceable calibration report and data