Fluke 715 Volt/mA Loop Calibrator
主要功能
- Compact mA calibrator for measuring 0-20 mA or 4-20 mA signals
- High accuracy—0.01% and 1 µA resolution
- Measures voltage output process signals from PLCs and transmitters
- Sources or simulates 4-20 mA loop current
- Sources voltage to 100 mV or 10 V
產品概述: Fluke 715 Volt/mA Loop Calibrator
Compact, lightweight, full-featured mA loop calibrator
The Fluke 715 Volt mA Calibrator delivers outstanding performance, durability, and reliability in a compact, lightweight tool. Offered in the rugged Fluke 80 Series digital multimeter package, the calibrator measures loop current as well as voltage output. It sources voltage to 200 mV or 20 V, measures loop current (0-20 mA, 4-20 mA) signals with 0 .01 % accuracy, and 1 µA resolution, and measures voltage output process signals from PLCs and transmitters. It can source or simulate 4-20 mA loop current and provides a 24 V loop supply with simultaneous current measurement.
- Provides step and linear ramp output function
- Features configurable zero and span settings
- Provides 24 V loop supply with simultaneous current measurement
- Features enhanced voltage and current measure and source accuracy
- Includes a 250-ohm HART resistor with loop power
Easy to use and carry
The 715 is also extremely easy to use with a simple push button interface. It features the rugged construction that Fluke tools are known for and is EMI tolerant as well as dust and splash resistant. It also features a removable battery door for quick battery changes after the 18 hours of battery life the 9 V battery provides. And the tool also comes with a protective yellow holster with test lead storage. For added convenience the Fluke 715 is also compatible with the ToolPak magnetic meter hanging system.
Related resources
規格: Fluke 715 Volt/mA Loop Calibrator
Functional Specifications | ||
Measure / Source mV | Range | 0 to 200 mV |
Resolution | 0.01 mV | |
Accuracy | 0.015% + 2 counts | |
Measure / Source V | Range | 0 to 20 V |
Resolution | 0.001 V | |
Accuracy | 0.01% + 2 counts | |
Measure / Source/ Simulate mA (% of span) | Range | 0 to 24 mA (-25% to 125%) |
Resolution | 0.001 mA | |
Accuracy | 0.01% + 2 counts | |
Sink (simulate transmitter) display mA or % of span | ||
Specifications | ||
Loop power | Range | 24 V DC |
Accuracy | ±10% | |
Drive; 20 mA into 1000 Ω for battery > 6.8 V; 700 Ω for battery 5.8 to 6.8 V | ||
Display | Clear 5 digit LCD | |
Environmental Specifications | ||
Operating temperature | -10°C to 55°C | |
Storage temperature | -40°C to 60°C | |
Humidity (without condensation) | 95% (10°C to 30°C) | |
75% (30°C to 40°C) | ||
45% (40°C to 50°C) | ||
35% (50°C to 55°C) | ||
Operating altitude | 3,000 m max | |
Safety Specifications | ||
Safety | CSA C22.2 No. 1010.1:1992 | |
Mechanical and General Specifications | ||
Size (L x W x D) | 187 x 87 x 32 mm | |
(7.93 x 3.86 x 2.06 in) | ||
Weight | Approx. 330 g | |
(21 oz) | ||
Warranty | 3 years | |
Shock and vibration | Random, 2 G, 5-500 Hz | |
1 m drop test | ||
Battery type | Single 9 V battery ANSI/NEDA 1604A or IEC 6LR619V alkaline |
機型: Fluke 715 Volt/mA Loop Calibrator
Volt/ mA Calibrator including:
- Protective Yellow Holster with Test Lead Storage
- Instructions Sheet (14 languages)
- single 9V alkaline battery
- Test Leads and Alligator Clips
- NIST- traceable calibration report and data