Fluke 62 MAX+/323/1AC IR Thermometer, Clamp Meter and Voltage Detector Kit
Tính năng chính
Fluke 62 MAX+. Small in size. Big on toughness.
- Dust and water-resistant: IP54 rated.
- Rugged: 3-meter (9.8-foot) drop tested.
- Ergonomically designed: Completely redesigned for a more natural hand fit.
- Distance to spot: 12:1.
- Dual lasers: Identifies area to be measured.
- Large, backlit display: Makes data easier to read, even in dark areas.
Fluke 323 True-rms Clamp Meter.Rugged. Reliable. Precise.
- 400 A AC current measurement.
- 600 VAC and DC voltage measurement.
- True RMS AC voltage and current for accurate measurements on non-linear signals.
- Resistance measurement up to 40 kΩ with continuity detection.
- Slim, ergonomic design.
- CAT IV 300V/CAT III 600 V safety rating.
Fluke 1AC II VoltAlert™ Voltage Detector
- Voltbeat™ technology and continuous self-test, so always know it’s working.
- Upon detection, tip glows and beeper sounds.
- Voltage detection of 90 to 1000 VAC.
- CAT IV 1000 V for added protection.
Fluke C115 Soft Case
- Lightweight soft case to provide optimal protection and accessory storage.
Tổng quan sản phẩm: Fluke 62 MAX+/323/1AC IR Thermometer, Clamp Meter and Voltage Detector Kit
This kit is designed to help electricians and HVAC technicians solve problems quicker. Test first for overheated electrical devices using an IR thermometer; then use the clamp meter and voltage detector to find out more about the problem
Thông số kỹ thuật: Fluke 62 MAX+/323/1AC IR Thermometer, Clamp Meter and Voltage Detector Kit
Fluke 62 MAX+ Infrared Thermometer
Specifications | ||
Temperature range | -30°C to 650°C (-22°F to 1202°F) | |
Accuracy | ±1.0°C or ±1.0% of reading, whichever is greater -10°C to 0°C: ±2.0 -30°C to -10°C: ±3.0 | |
Response time (95%) | < 300 ms (95% of reading) | |
Spectral response | 8 to 14 microns | |
Emissivity | 0.10 to 1.00 | |
Optical resolution | 12:1 (calculated at 90% energy) | |
Display resolution | 0.1°C (0.2°F) | |
Repeatability of readings | ±0.5% of reading or < ±0.5°C (1°F), whichever is greater | |
Power | AA battery | |
Battery life | 8 hours with laser and backlight on | |
Physical Specifications | ||
Weight | 255 g (8.99 oz) | |
Size | 175 x 85 x 75 mm (6.88 x 3.34 x 2.95 in) | |
Operating temperature | 0°C to 50°C (32°F to 122°F) | |
Storage temperature | -20°C to 60°C (-4°F to 140°F), (without battery) | |
Operating humidity | 10% to 90% RH non-condensing at 30°C (86°F) | |
Operating altitude | 2000 meters above mean sea level | |
Storage altitude | 12,000 meters above mean sea level | |
IP rating | IP 54 per IEC 60529 | |
Drop test | 3 meters | |
Vibration and shock | IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms | |
EMC | EN 61326-1:2006 EN 61326-2:2006 | |
Standards and agency approval | Compliance | EN/IEC 61010-1: 2001 |
Laser safety | FDA and EN 60825-1 Class II |
Fluke 323 True RMS Clamp Meter
Specifications | ||
AC current | Range | 400.0 A |
Accuracy | 2% ±5 digits (45 Hz to 65 Hz) 2.5% ±5 digits (65 Hz to 400 Hz) | |
AC voltage | Range | 600.0 V |
Accuracy | 1.5% ±5 digits | |
DC voltage | Range | 600.0 V |
Accuracy | 1.0% ±5 digits | |
Resistance | Range | 400.0 Ω/ 4000 Ω |
Accuracy | 1.0% ±5 digits | |
Continuity | ≤ 70 Ω | |
AC response | True-rms | |
Data hold | Yes | |
Size | H x W x D (mm) | 207 x 75 x 34 |
Max wire diameter | 30 mm (600 MCM) | |
Weight | 265 g | |
Category rating | CAT III 600 V CAT IV 300 V | |
Warranty | Two-year |
Fluke 1AC-II VoltAlert
Specifications | ||
Operating principle | Senses the steady state electrostatic field produced by ac voltage through insulation without requiring contact to the bare conductor. A red glow at the tip and a beeping noise (if not switched OFF) indicates the presence of voltage. | |
Voltage sensing ranges | Nominally, 90 VAC to 1000 VAC or 200 VAC to 1000 VAC depending on model, 45 Hz to 405 Hz; also a 20 V to 90 V control circuit model | |
Detector tip style | Blade or round, depending on model | |
Light source | One high intensity red LED | |
Agency approvals | c CSA us, CE, C-Tick | |
Safety rating | 1000 V, CAT IV | |
IP rating | IP 40 | |
Operating temperature | -10°C to 50°C | |
Operating humidity ranges | 0% to 95% | (0°C to 30°C) |
0% to 75% | (30°C to 40°C) | |
0% to 45% | (40°C to 55°C) | |
Operating altitude | 3000 meters | |
Batteries | 2 AAA alkaline batteries included | |
Product does not respond to random electrostatic discharge. |
Model: Fluke 62 MAX+/323/1AC IR Thermometer, Clamp Meter and Voltage Detector Kit
Fluke 62 MAX+/323/1AC Kit
Fluke 62 MAX+/323/1AC IR Thermometer, Clamp Meter and Voltage Detector Kit
Includes:
- Fluke 62 MAX+ IR Thermometer
- Fluke 323 True-rms Clamp Meter
- Fluke 1AC II VoltAlert Voltage Detector
- C115 Soft Case
Sách hướng dẫn + tài nguyên: Fluke 62 MAX+/323/1AC IR Thermometer, Clamp Meter and Voltage Detector Kit
- 323/324/325 | Sổ tay hướng dẫn sử dụng
- 302+/303/305/323/324/325 | Báo cáo về bộ nhớ khả biến
- 323/324/325 | Hướng dẫn tham khảo nhanh
- 323/324/325 | Bảng thông tin an toàn
- 323/324/325 | Bảng thông tin an toàn bổ sung
- 323/324/325 | Sổ tay hướng dẫn hiệu chuẩn
- 323/324/325 | Sổ tay hướng dẫn hiệu chuẩn bổ sung
- 62 MAX, Fluke62 MAX + | Báo cáo về bộ nhớ khả biến
- 62 Max/62 Max+ | Sổ tay hướng dẫn hiệu chuẩn