Fluke a3001 FC Wireless iFlex® AC Current Module
Compare products: ampe kìm
- Ampe kìm hiệu dụng thực 393 FC CAT III 1500 V với iFlex
- Ampe kìm True RMS AC/DC Fluke 377 FC với iFlex™
- Ampe kìm True-rms AC/DC Fluke 378 FC với iFlex™
- Fluke 376 FC True-RMS Clamp Meter with iFlex
- Fluke 325 True-rms Clamp Meter
- Ampe kìm AC/DC hiệu dụng thực hiển thị từ xa Fluke 381 với iFlex
- Fluke 902 FC True-RMS HVAC Clamp Meter
- Fluke a3000 FC Wireless AC Current Clamp Module
- Fluke 323 True-rms Clamp Meter
- Fluke 324 True-rms Clamp Meter
- Fluke 373 True-rms AC Clamp Meter
- Fluke 365 Detachable Jaw True-rms AC/DC Clamp Meter
- Fluke 773 Milliamp Process Clamp Meter
- Fluke 355 True-rms 2000 A Clamp Meters
- Fluke 353 True-rms 2000 A Clamp Meters
- Fluke a3002 FC Wireless AC/DC Current Module
- Fluke 772 Milliamp Process Clamp Loop Meter
- Fluke a3003 FC Wireless 2000 A DC Current Clamp Meter
- Fluke a3004 FC Wireless 4-20 mA DC Clamp Meter
- Fluke 771 Milliamp Process Clamp Meter
- Fluke T5-1000 Voltage, Continuity and Current Tester
- Fluke T5-600 Voltage, Continuity and Current Tester
Tính năng chính
- Measure and record up to 65,000 readings wirelessly
- Easier wire access around large conductors in tight spaces
- Inrush function; magnetic hanging strap
Tổng quan sản phẩm: Fluke a3001 FC Wireless iFlex® AC Current Module
Product Overview: Fluke a3001 FC Wireless iFlex® AC Current Module
The Fluke a3001 FC Wireless iFlex AC Current Module is a fully functional true-rms current meter that wirelessly relays measurements to the Fluke Connect® mobile app.
The a3001 puts the tool, not your body, near live electrical panels. Connect the a3001 FC current module and read the results on your smartphone from a safe distance. You can save and share measurements from the field with your team anytime, from anywhere.
Isolating intermittent electrical faults easily
Leave your a3001 connected to log measurements and walk away to address other issues. Download the data for further analysis on our phone. Record over time to monitor circuit load changes for an hour, a shift or a week. Use the Fluke Connect wireless USB adapter to collect logged data from remote modules by walking past a working module and downloading logged data.
Faster and cheaper 3-phase testing
When your cabinet is de-energized, attach a Fluke a3001 FC Wireless iFlex AC Current Module to each phase. Close, re-energize and start taking readings in 1/3 of the time. What used to take hours and use costly equipment can be done in minutes with an affordable Fluke Connect wireless system.
Log, analyze, and diagnose easily You can solve problems faster by seeing live measurements from multiple test points on a single screen. Send data from the panel to your laptop and go from logging to analysis and diagnosis with the a3001 connected. Once you’ve gathered the measurements, you can perform for analysis with your PC and share the results using Fluke Cloud™ storage and ShareLive™ video call. Share and view data or graphs to get input from team members.
Thông số kỹ thuật: Fluke a3001 FC Wireless iFlex® AC Current Module
Specifications | ||
Range | 0.5 A to 2500 A AC | |
Resolution | 0.1 A | |
Accuracy | 3% ± 5 digits (5 Hz to 500 Hz) | |
Crest factor (50 Hz/60 Hz) | 3.0 at 1100 A 2.5 at 1400 A 1.42 at 2500 A Add 2% for C.F. > 2 | |
LCD w/backlight | 3½ digits | |
Log rate/interval | 1 sec minimum/adjustable by PC or front panel | |
Battery type | 2 AA, NEDA 15 A, IEC LR6 | |
Battery life | 400 hours | |
Memory | Record up to 65,000 readings | |
RF communications | 2.4 GHZ ISM Band | |
RF communication range | Open air, unobstructed | Up to 20 m |
Obstructed, sheetrock wall | Up to 6.5 m | |
Obstructed, concrete wall or steel electrical enclosure | Up to 3.5 m | |
Operating temperature | -10°C to +50°C | |
Storage temperature | -40°C to +60°C | |
Temperature coefficient | Add 0.1 X (specified accuracy) / °C (< 18°C or > 28°C) | |
Operating humidity | 90% at 35°C 75% at 40°C 45% at 50°C | |
Altitude | Operating | 2,000 m |
Storage | 12,000 m | |
EMC | EN 61326-1:2006 | |
Safety compliance | IEC 61010-1, 600 V CAT IV/1000 V CAT III, 3rd edition | |
Safety rating | CAT IV 600 V, CAT III 1000 V | |
Certifications | CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE | |
Ingress Protection (IP) rating | IP42 | |
Pollution Degree | 2 | |
Jaw opening | 25.4 cm (10 in) coil | |
Size (HxWxD) | 16.5 cm x 6.35 cm x 1.4 cm (6.5 in x 2.5 in x 1.4 in) | |
Weight | .22 kg (8 oz) | |
Warranty | Three years | |
Note: Not compatible with Fluke CNX test tools |
Model: Fluke a3001 FC Wireless iFlex® AC Current Module
Includes:
- True-RMS flexible current meter
- iFlex i2500-10 Flexible Current Probe
Sách hướng dẫn + tài nguyên: Fluke a3001 FC Wireless iFlex® AC Current Module
- 3000 FC | Sổ tay hướng dẫn sử dụng
- 3000 FC | Hướng dẫn tham khảo nhanh
- 3000 FC | Sổ tay hướng dẫn hiệu chuẩn
- 3000 FC | Sổ tay hướng dẫn hiệu chuẩn bổ sung
- 3000 FC | Bảng thông tin an toàn
- a3000 FC | Bảng thông tin an toàn
- a3000 FC | Hướng dẫn tham khảo nhanh
- a3000 FC | Sổ tay hướng dẫn hiệu chuẩn
- a3001 FC | Hướng dẫn tham khảo nhanh
- a3001 FC | Sổ tay hướng dẫn hiệu chuẩn
- a3001 FC | Bảng thông tin an toàn
- a3001 FC | Bảng thông tin an toàn bổ sung
- a3002 FC | Hướng dẫn tham khảo nhanh
- a3002 FC | Sổ tay hướng dẫn hiệu chuẩn
- a3002 FC | Bảng thông tin an toàn
- Fluke Connect | Hướng dẫn tham khảo nhanh
- Fluke Connect Wi-Fi to Thermal Imager | Hướng dẫn tham khảo nhanh
- ir3000 FC | Hướng dẫn tham khảo nhanh
- pc 3000 FC | Bản hướng dẫn
- t3000 FC | Sổ tay hướng dẫn hiệu chuẩn
- t3000 FC | Hướng dẫn tham khảo nhanh
- t3000 FC | Bảng thông tin an toàn
- t3000 FC | Bảng thông tin an toàn bổ sung
- v3000 FC | Sổ tay hướng dẫn hiệu chuẩn
- v3000 FC v3001 FC | Hướng dẫn tham khảo nhanh
- v3000 FC v3001 FC | Bảng thông tin an toàn
- v3000 FC, v3001 FC, a3000 FC, a3001 FC, a3002 FC, t3000 FC | Báo cáo về bộ nhớ khả biến
- v3001 FC | Sổ tay hướng dẫn hiệu chuẩn
- Performing predictive maintenance with Fluke Connect™
- How to email a measurement using the Fluke Connect app
- Saving measurements with AutoRecord™ measurements
- Connecting a thermal imager to your iPhone
- Measurement history in one place using EquipmentLog™ history
- Identifying intermittent conditions with TrendIt™ graphs
- Measuring from a safe distance using the Fluke Connect™ app
- How to create an equipment baseline with EquipmentLog™ history
- Share equipment health with EquipmentLog™ history
- How to share measurements on equipment using the Fluke Connect™ app
- Using ShareLive™ video call to share live measurements and video
- How to record measurements and graphs
- Viewing and graphing three phase measurements
- Connecting the T3000 FC with the Fluke Connect™ app
- Introduction to 789FC
- How to save measurements to EquipmentLog™ history
- Connecting multiple tools at the same time with Fluke Connect®