Fluke i3000s Flex-36 AC Current Clamp, 915 mm (36 in.)
Tính năng chính
- Three ranges
- 30 A
- 300 A
- 3000 A, 1, 10 or 100 mV/A output
- Ideal for current measurement on thick and hard to reach conductors without breaking the circuit
- Maximum conductor diameter 178 mm (7 in.)
- CAT III 600 V safety rating
Also available in pack of 4 for use in Power Quality Analyzers. Click here for more info.
Tổng quan sản phẩm: Fluke i3000s Flex-36 AC Current Clamp, 915 mm (36 in.)
The i3000s Flex is an ac current clamp utilizing the Rogowski principle. It can be used to measure currents up to 3000 A when used in conjunction with oscilloscopes, recorders or data loggers. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas.
Thông số kỹ thuật: Fluke i3000s Flex-36 AC Current Clamp, 915 mm (36 in.)
Electrical Specification | |
Current ranges | 30 A |
300 A | |
3000 A | |
AC rms | |
Output sensitivity (AC-coupled) | 100 mV |
10 mV | |
1mV per A | |
Load impedance | 100 kΩ minimum |
Accuracy | at +25°C: ±1% of range (45 Hz to 65 Hz) |
Linearity | 10% to 100% of range: ±0.2% of reading |
Noise | 8 mV AC rms (30 A) |
2 mV AC rms (300 A, 3000 A) | |
Frequency range | 10 Hz to 50 kHz (-3 dB) |
Phase error | < ±1° (45 Hz to 65 Hz) |
±10° (at 20 kHz) | |
Position sensitivity (with cable > 25 mm from the coupling) | Position sensitivity: From 1% up to 3% of range with cable, depending on distance from the center (see figure left). Measurements closer than 25 mm from the coupling are typically greater than 3% of range. |
External field | with cable > 200 mm from the head: ±1% of range |
Power supply | 2 x AA/MN 1500/LR6 Alkaline, 400 hours, low battery indicator |
Temperature coefficient | ±0.08% of reading per °C |
Working voltage | see Safety standards section: 600 V AC rms or DC |
General Specifications | |
Head circumference | 915 mm (36 in.) |
Head cable diameter | 14.3 mm (0.56 in) |
Head bend radius | 38.1 mm (1.5 in) |
Cable length (head to electronics) | 2 m (6.56 ft) |
Output connection | 0.5 m cable terminated with safety BNC connector. Supplied with 4mm safety plug adapter |
Operating temperature range | -20°C to +90°C (-4°F to 190°F) (head) |
-20°C to +85°C (-4°F to 185°F) (electronics) | |
Storage temperature range | -40°C to +105°C (-40°F to 221°F) (head) |
-20°C to +85°C (-4°F to 185°F) (electronics) | |
Operating humidity | 15% to 85% (non-condensing) |
Weight | 180 g (0.396 lb) (head) |
190 g (0.419 lb) (electronics) | |
Safety standards | BS EN 61010-1: 2001 |
BS EN 61010-2-032: 2002 | |
BS EN 61010-031: 2002 | |
600 Vrms, Category III, Pollution Degree 2 | |
Use of the probe on uninsulated conductors is limited to 600 V AC rms or DC and frequencies below 1 kHz | |
EMC standards | EN 61326: 1998 +A1, A2, and A3 |
Head cable length (double insulated) | 610 mm or 914 mm, depending on model |
Model: Fluke i3000s Flex-36 AC Current Clamp, 915 mm (36 in.)
Fluke i3000s Flex 36
AC Current Clamp, 915 mm (36 in.)