5141- 5142 -5144 molbox RFM Gas Flow Calibrator Kits

Sonlandırıldı
Bu ürünün üretimi sona erdirilmiştir veya bu ürün yeniden sınıflandırılmıştır

Ürün İncelemesi: 5141- 5142 -5144 molbox RFM Gas Flow Calibrator Kits

A new standard in high end gas flow calibration


Fluke Calibration revolutionized high end gas flow calibration with the introduction of molbox/ molbloc mass flow standards. molbox/molbloc systems have replaced large, inflexible, error prone volumetric piston provers and bell provers with a compact, easy to use, versatile digital standard. molbox/molbloc systems are the standard of choice for high end calibration labs and mass flow device manufacturers around the world. Improvements offered by molbox/molbloc include:

  • True mass flow calibration and traceability— no corrections from volumetric to mass
  • Real-time digital mass flow indication, loaded with features—easily automated
  • No moving parts—uninterrupted gas flow measurement, no fluctuations from piston stroke
  • Flexibility to be positioned upstream or downstream— can calibrate at many line pressures
  • Modular components allows future upgrade and expansion
  • Very wide range with small footprint—no flow straightening hardware required

Whether your requirement is manual calibration of a simple variable area flow meter (rotameter) or fully automated calibration of a mass flow controller (MFC), molbox/molbloc systems offer the ideal solution. A molbox RFM with one or more molbloc flow elements can cover a wide range of flow calibration devices with total one-year measurement uncertainty of ± 0.5 % of reading. If your needs change, molbloc flow elements can be added, with models covering flows from 1 sccm to over 5000 slm (175 scfm). If better measurement uncertainty is needed, the same flow elements can be used with molbox1+ to achieve accuracy as good as ± 0.125 % of reading.

 

Özellikler: 5141- 5142 -5144 molbox RFM Gas Flow Calibrator Kits

Measurement specifications
Gas calibration includedNitrogen (N2), Air
Maximum working measurement line pressure600 kPa (87 psi) absolute
Measurement range<1sccm to 50 slm, depending on model. Flow ranges depend on test gas. Ranged indicated for N2 and Air.
General specifications
Power requirements85 V ac to 264 V ac, 47 Hz to 440 Hz, 18 VA max consumption
Normal operating temperature range15 °C to 30 °C (59 °F to 86 °F)
Storage temperature range-20 °C to 70 °C (-4 °F to 158 °F)
VibrationMeets MIL-T-28800D
molbox RFM weight and dimwnsions2.55 kg (5.6 lb) max
8 cm x 22.5 cm x 20 cm (3.1 in x 8.9 in x 7.9 in) approx
molstic with molbloc weight and dimensions (max)9 kg (20 lb)
19 cm x 81.28 cm x 15.25 cm (7.5 in x 32 in x 6 in) approx
Supply gas required99.998% pure N2 or Air regulated to 90 psig (600 kPa)
Note: a fine pressure regulator is included, but an additional regulator (not included) may be required to reduce pressure supplied to the 514X kit to approximately 90 psi
Gas calculations reportedNitrogen (N2), Air, Argon (Ar), Carbon Monoxide (CO), Helium (He), Oxygen (O2),
Carbon Dioxide (CO2), Carbon Tetrafluoride (CF4), Ethane (C2<;/sub>H6), Ethylene
(C2H4), Fluoroform (CHF3), Hexafluoroethane (C2F6), Hydrogen (H2), Methane (CH4),
Nitrous Oxide (N2O), Propane (C3H8), Sulfur Hexafluoride (SF6)
Flow connections for gas supply and device under test1/4 in tube with adapters included for 1/4 in NOT and 1/4 in BSP

Modeller: 5141- 5142 -5144 molbox RFM Gas Flow Calibrator Kits

5141-100
molbox RFM, molbloc 5E1-L 10 to 100 sccm

Included:
  • molbox RFM (5141 kits) or molbox RFM-M (5142 and 5144 kits) reference flow monitor with quick connect molbloc pressure lines, molbloc communication cable, line cord and user manual
  • molbloc 5E1-L laminar flow element 
  • molstic-L mounting system, with fine pressure regulator and an isolation valve and precise flow metering valve for each molbloc-L
  • Tubing and adaptors to connect gas supply and device under test, including 1/4 in tube fitting, 1/4 in NPT female, 1/4 in NPT male, 1/8 in NPT male and 1/4 in BSP male
5141-1K
molbox RFM, molbloc 5E2-L 100 to 1,000 sccm

Included:
  • molbox RFM (5141 kits) or molbox RFM-M (5142 and 5144 kits) reference flow monitor with quick connect molbloc pressure lines, molbloc communication cable, line cord and user manual
  • molbloc 5E2-L laminar flow element 
  • molstic-L mounting system, with fine pressure regulator and an isolation valve and precise flow metering valve for each molbloc-L
  • Tubing and adaptors to connect gas supply and device under test, including 1/4 in tube fitting, 1/4 in NPT female, 1/4 in NPT male, 1/8 in NPT male and 1/4 in BSP male
5141-10K
molbox RFM, molbloc 5E3-L 1 to 10 slm

Included:
  • molbox RFM (5141 kits) or molbox RFM-M (5142 and 5144 kits) reference flow monitor with quick connect molbloc pressure lines, molbloc communication cable, line cord and user manual
  • molbloc 5E3-L laminar flow element
  • molstic-L mounting system, with fine pressure regulator and an isolation valve and precise flow metering valve for each molbloc-L
  • Tubing and adaptors to connect gas supply and device under test, including 1/4 in tube fitting, 1/4 in NPT female, 1/4 in NPT male, 1/8 in NPT male and 1/4 in BSP male
5141-50K
molbox RFM, molbloc 3E4-L 5 to 50 slm

Included:
  • molbox RFM (5141 kits) or molbox RFM-M (5142 and 5144 kits) reference flow monitor with quick connect molbloc pressure lines, molbloc communication cable, line cord and user manual
  • molbloc 3E4-L laminar flow element 
  • molstic-L mounting system, with fine pressure regulator and an isolation valve and precise flow metering valve for each molbloc-L
  • Tubing and adaptors to connect gas supply and device under test, including 1/4 in tube fitting, 1/4 in NPT female, 1/4 in NPT male, 1/8 in NPT male and 1/4 in BSP male
5142-1K
molbox RFM-M, molbloc 5E2-L 10 to 1,000 sccm

Included:
  • molbox RFM (5141 kits) or molbox RFM-M (5142 and 5144 kits) reference flow monitor with quick connect molbloc pressure lines, molbloc communication cable, line cord and user manual
  • molbloc 5E2-L laminar flow element 
  • molstic-L mounting system, with fine pressure regulator and an isolation valve and precise flow metering valve for each molbloc-L
  • Tubing and adaptors to connect gas supply and device under test, including 1/4 in tube fitting, 1/4 in NPT female, 1/4 in NPT male, 1/8 in NPT male and 1/4 in BSP male
5142-10K
molbox RFM-M, molbloc 5E3-L 0.1 to 10 slm

Included:
  • molbox RFM (5141 kits) or molbox RFM-M (5142 and 5144 kits) reference flow monitor with quick connect molbloc pressure lines, molbloc communication cable, line cord and user manual
  • molbloc 5E3-L laminar flow element 
  • molstic-L mounting system, with fine pressure regulator and an isolation valve and precise flow metering valve for each molbloc-L
  • Tubing and adaptors to connect gas supply and device under test, including 1/4 in tube fitting, 1/4 in NPT female, 1/4 in NPT male, 1/8 in NPT male and 1/4 in BSP male
5142-50K
molbox RFM-M, molbloc 3E4-L 0.5 to 50 slm

Included:
  • molbox RFM (5141 kits) or molbox RFM-M (5142 and 5144 kits) reference flow monitor with quick connect molbloc pressure lines, molbloc communication cable, line cord and user manual
  • molbloc 3E4-L laminar flow element 
  • molstic-L mounting system, with fine pressure regulator and an isolation valve and precise flow metering valve for each molbloc-L
  • Tubing and adaptors to connect gas supply and device under test, including 1/4 in tube fitting, 1/4 in NPT female, 1/4 in NPT male, 1/8 in NPT male and 1/4 in BSP male
5144-50K
molbox RFM-M, molblocs 5E2-L and 3E4-L10 sccm to 50 slm

Included:
  • molbox RFM (5141 kits) or molbox RFM-M (5142 and 5144 kits) reference flow monitor with quick connect molbloc pressure lines, molbloc communication cable, line cord and user manual
  • molbloc 5E2-L and 3E4-L laminar flow elements
  • molstic-L mounting system, with fine pressure regulator and an isolation valve and precise flow metering valve for each molbloc-L
  • Tubing and adaptors to connect gas supply and device under test, including 1/4 in tube fitting, 1/4 in NPT female, 1/4 in NPT male, 1/8 in NPT male and 1/4 in BSP male