iFlex Özellikli 393 FC CAT III 1500 V True-rms Pensampermetre

  • 393 FC CAT III 1500 V True-rms Clamp Meter
  • The Fluke 393 clamp meter has a very thin jaw for cramped combiner boxes, but still clamps around a 34 mm cable.
  • Fluke 393 FC clamp calculates and dsiplay dc power (kVA) enerated by a solar panel
  • Measurements sent to a smartphone and the cloud via Fluke Connect software.
  • Video Player is loading.
    Current Time 0:00
    Duration 0:00
    Loaded: 0%
    Stream Type LIVE
    Remaining Time 0:00
     
    1x
      • Chapters
      • descriptions off, selected
      • subtitles off, selected
      1. 393 FC CAT III 1500 V True-rms Clamp Meter
      2. The Fluke 393 clamp meter has a very thin jaw for cramped combiner boxes, but still clamps around a 34 mm cable.
      3. Fluke 393 FC clamp calculates and dsiplay dc power (kVA) enerated by a solar panel
      4. Measurements sent to a smartphone and the cloud via Fluke Connect software.
      5. Fluke 393 FC CAT III 1500 V True-rms Clamp Meter

      Temel özellikler

      • CAT III 1.500 V dereceli pensampermetre ile güvenli bir şekilde ölçüm yapın
      • İçi çok dolu toplama panolarındaki kablolara erişebilmek için ince ağız
      • Dış mekânda kullanım için IP54 dereceli dayanıklılık 
      • DC güç ölçümü, ses polaritesi ve görsel devamlılık ile verimli çalışın

      Ürün İncelemesi: iFlex Özellikli 393 FC CAT III 1500 V True-rms Pensampermetre

      iFlex'li 393 FC CAT III 1500 V True-rms Güneş Enerjisi Pensampermetresi, güneş enerjisi fotovoltaik (PV) kurulum teknisyenleri ve yüksek gerilimli DC ortamlarında çalışan bakım uzmanları için tasarlanmıştır. Kesintisiz güç kaynakları için PV diziler, rüzgâr gücü, elektrikli demir yolları ve veri merkezileri akü grupları. Pensampermetre, test uçlarıyla 1.500 V DC ve 1.000 V AC; pens ağzıyla ise 999,9 A DC'ye veya AC'ye kadar ölçüm yapabilir. Dahil edilen iFlex esnek akım probu, AC akım ölçümlerini 2.500 ampere kadar genişletir. 393’ün ince bir ağzı vardır ve kalabalık toplama panolarındaki kablolara erişmenizi sağlar. Ayrıca test uçları, çalışmalarınız düşünülerek tasarlanmış ve CAT III 1500 V DC seviyesine derecelendirilmiştir.


      Diğer temel işlevler:
      • IP54 derecelendirmesine sahip olması sayesinde açık havada güneş enerjisi dizileri ve rüzgâr gücü sistemlerinde çalışma için idealdir 
      • kVA birimiyle değerleri gösteren DC güç ölçümü
      • Ses Polaritesi göstergesi, kazayla yanlış kablolamanın önlenmesine yardımcı olur
      • Visual Continuity özelliğinin ekranda sunduğu parlak yeşil ışık, karanlık ve gürültülü ortamlarda çalışma için idealdir
      • Fluke Connect yazılımı üzerinden test sonuçlarının kaydedilmesi ve raporlanması
      • Mevcut iFlex esnek akım probu, AC akım ölçülürken dar alanlarda eşsiz kablo erişimi sağlar.  iFlex probu, çok küçük alanlara sığacak şekilde bükülebilir ve hassas akım ölçümleri sağlar.
       

      Dahil:

      • Fluke 393 FC CAT III 1500 V TRMS pensampermetre
      • Test uçları, CAT III 1.500 V dereceli, dik açılı fişler, güvenlik kapaklı
      • iFlex 18 inç esnek akım probu
      • TPAK manyetik asma bandı
      • Üstün kaliteli taşıma çantası
      • 3 yıl garanti

      Özellikler: iFlex Özellikli 393 FC CAT III 1500 V True-rms Pensampermetre

      Teknik Özellikler:   
      Genel   
      Herhangi bir Uçla Topraklama arasındaki maksimum gerilim  
      AC1.000 V  
      DC1.500 V  
      Piller2 AA IEC LR6 alkalin  
      EkranArkadan aydınlatmalı ikili ekran  
      Otomatik Güç Kapatma20 dakika  
      Elektriksel   
      Hassasiyet   
      Cihazın hassaslığı 18 °C - 28 °C çalışma sıcaklığı ve %0 - %75 bağıl nem koşulları altında kalibrasyondan sonra 1 yıl süreyle geçerlidir. Hassaslığa ilişkin teknik özellikler şu şekildedir: ±([Okuma Değerinin % oranı] + [En Önemsiz Basamak Sayısı]).
      Sıcaklık Katsayıları28 °C'nin üzerindeki veya 18 °C'nin altındaki her °C için 0,1 x oranında belirtilen hassaslık ekleyin
      AC Akım: Ağız   
      Aralık999,9 A  
      Çözünürlük0,1 A  
      Hassasiyet%2 + 5 basamak (10 Hz - 100 Hz) 
       %2,5 + 5 basamak (100 Hz - 500 Hz) 
      Crest Faktörü (50/60 Hz)600,0 A'da 2,5  
       500,0 A'da 3,0  
       999,9 A'da 1,42  
       C.F. için %2 ekleyin >2  
      AC Akım: Esnek Akım Probu   
      Aralık999,9 A  
       2.500 A  
      Çözünürlük0,1 A (≤999,9 A)  
       1 A (≤2.500 A)  
      Hassasiyet%3 RD + 5 basamak (10 Hz - 500 Hz) 
      Crest Faktörü (50/60 Hz)1.400 A'da 2,5  
       1.100 A'da 3,0  
       2.500 A'da 1,42  
       C.F. için %2 ekleyin >2  
      Konum Hassasiyeti   
      NEC sembolü
      En İyi Değere Olan Uzaklıki2500-10 Flexi2500-18 FlexHata
      A0,5 inç (12,7 mm)1,4 inç (35,6 mm)%±0,5
      B0,8 inç (20,3 mm)2,0 inç (50,8 mm)%±1,0
      C1,4 inç (35,6 mm)2,5 inç (63,5 mm)%±2,0
      Ölçüm belirsizliğinde, optimum konumda bir merkezi primer iletken, harici elektriksel ya da manyetik alan bulunmaması ve çalışma sıcaklığı aralığında bulunulduğu varsayılmaktadır.
          
      DC Akım   
      Aralık999,9 A  
      Çözünürlük0,1 A  
      Hassasiyet%2 RD + 5 basamak[1]  
       [1]Ofset telafisinde ZERO (B) işlevini kullanırken.
      AC Gerilimi   
      Aralık600,0 V  
       1.000 V  
      Çözünürlük0,1 V (≤600,0 V)  
       1 V (≤1.000 V)  
      Hassasiyet%1 RD + 5 basamak (20 Hz - 500 Hz) 
      DC Gerilimi   
      Aralık600,0 V  
       1.500 V  
      Çözünürlük0,1 V (≤600,0 V)  
       1 V (≤1.500 V)  
      Hassasiyet%1 RD + 5 basamak  
      mV dc   
      Aralık500,0 mV  
      Çözünürlük0,1 mV  
      Hassasiyet%1 RD + 5 basamak  
      Amper Frekansı: Ağız   
      Aralık5,0 Hz ila 500,0 Hz  
      Çözünürlük0,1 Hz  
      Hassasiyet%0,5 RD + 5 basamak  
      Tetik Düzeyi5 Hz - 10 Hz, ≥10 A  
       10 Hz - 100 Hz, ≥5 A  
       100 Hz - 500 Hz, ≥10 A  
      Amper Frekansı: Esnek Akım Probu   
      Aralık5,0 Hz ila 500,0 Hz  
      Çözünürlük0,1 Hz  
      Hassasiyet%0,5 RD + 5 basamak  
      Tetik Düzeyi5 Hz - 20 Hz, ≥25 A  
       20 Hz - 100 Hz, ≥20 A  
       100 Hz - 500 Hz, ≥25 A  
      Gerilim Frekansı   
      Aralık5,0 Hz ila 500,0 Hz  
      Çözünürlük0,1 Hz  
      Hassasiyet%0,5 RD + 5 basamak  
      Tetik Düzeyi5 Hz - 20 Hz, ≥5 V  
       20 Hz - 100 Hz, ≥5 V  
       100 Hz - 500 Hz, ≥10 V  
      DC Gücü   
      Aralık600,0 kVA (600,0 V DC aralığı)  
       1.500 kVA (1.500 V DC aralığı)  
      Çözünürlük0,1 kVA  
       1 kVA  
      Hassasiyet%2 RD + 2,0 kVA  
       %2 RD + 20 kVA  
      Direnç   
      Aralık600,0 Ω  
       6.000 Ω  
       60,00 kΩ  
      Çözünürlük0,1 Ω (≤ 600,0 Ω)  
       1 Ω (≤ 6.000 Ω)  
       0,01 kΩ (≤60,00 kΩ)  
      Hassasiyet%1 RD + 5 basamak  
      Kapasitans   
      Aralık100,0 μF  
       1.000 μF  
      Çözünürlük0,1 μF (≤100,0 μF)  
       1 μF (≤1.000 μF)  
      Hassasiyet%1 RD + 5 basamak  
      Ani Akım Tetik Seviyesi5 A  
      Mekanik   
      Boyut (U x G x Y)281 mm x 84 mm x 49 mm  
      Ağırlık (piller ile birlikte)520 g  
      Ağız Açıklığı34 mm  
      Esnek Akım Probu Çapı7,5 mm  
      Esnek Akım Probu Kablo Uzunluğu   
      (baştan elektronik konektöre kadar)1,8 m  
      Ortam Değerleri   
      Çalışma Sıcaklığı-10 °C ila 50 °C  
      Depolama Sıcaklığı-40 °C ila 60 °C  
      Çalışma NemiYoğuşmasız (<10 °C)  
       ≤%90 RH (10 °C - 30 °C'de)  
       ≤%75 RH (30 °C - 40 °C'de)  
       ≤%45 RH (40 °C - 50 °C'de)  
      Çalışma Yüksekliği2.000 m  
      Depolama Yüksekliği12.000 m  
      Giriş Koruması (IP) DerecelendirmesiIEC 60529: IP54 çalışmama durumunda  
      Elektromanyetik Uyumluluk (EMC)   
      UluslararasıIEC 61326-1: Taşınabilir, Elektromanyetik Ortam, IEC 61326-2-2 CISPR 11: Grup 1, Sınıf A
       Grup 1: Ekipman, dahili çalışması için gereken, kasten oluşturulan ve/veya kullanılan iletken bağlanmış telsiz frekans enerjisi içerir.
      Sınıf A: Ekipman; evler ve ev olarak kullanılan binalara besleme yapan düşük gerilimli güç kaynağı ağlarına doğrudan bağlı olan yerler haricinde bütün yerlerde kullanım için uygundur. İletilen ve yayılan bozulmalar sebebiyle diğer ortamlarda elektromanyetik uyumluluğu sağlamak konusunda olası zorluklarla karşılaşılabilir.
      Dikkat: Bu ekipman, mesken ortamlarda kullanım için tasarlanmamıştır ve bu tür ortamlarda radyo sinyaline karşı yeterli koruma sağlamayabilir.
      Kore (KCC)Sınıf A ekipman (Endüstriyel Yayıncılık ve İletişim Ekipmanı)
       Sınıf A: Ekipman, endüstriyel elektromanyetik dalga yayan ekipman gerekliliklerini karşılar ve satıcı veya kullanıcı bunu dikkate almalıdır. Bu ekipmanın çalışma ortamlarında kullanılması amaçlanmıştır; ekipman ev kullanımına uygun değildir.
      ABD (FCC)47 CFR 15 alt bölüm B. Bu ürün 15.103 bendi uyarınca istisnai ürün olarak değerlendirilir.
      Güvenlik   
      GenelIEC 61010-1, Kirlilik Derecesi 2 
      ÖlçümIEC 61010-2-032: CAT III 1.500 V / CAT IV 600 V 
       IEC 61010-2-033: CAT III 1.500 V / CAT IV 600 V 
      Kablosuz Telsiz   
      Telsiz frekansı sertifikasıFCC ID: T68-FBLE, IC: 6627A-FBLE 
      Kablosuz Telsiz Frekans Aralığı2.400 MHz ila 2.483,5 MHz  
      Çıkış Gücü<100 mW  
      BASİTLEŞTİRİLMİŞ AB UYGUNLUK BEYANI  
      Fluke, işbu Üründe bulunan radyo ekipmanının 2014/53/EU sayılı Direktif ile uyumlu olduğunu beyan eder.
      AB beyanının tam metni aşağıdaki İnternet adresinde mevcuttur:  
      www.fluke.com/en-us/declaration-of-conformity   

      Modeller: iFlex Özellikli 393 FC CAT III 1500 V True-rms Pensampermetre

      393 FC
      iFlex Özellikli 393 FC CAT III 1500 V True-rms Pensampermetre

      Satın alın

      İçerik:

      • iFlex Özellikli Fluke 393 FC CAT III 1500 V True-RMS Pensampermetre
      • Test uçları, CAT III 1.500 V dereceli, dik açılı fişler, güvenlik kapaklı
      • iFlex 18 inç esnek akım probu
      • TPAK manyetik asma bandı
      • Üstün kaliteli taşıma çantası
      • 3 yıl garanti

      Fluke Connect tüm ülkelerde mevcut değildir.

      *Tüm modeller tüm bölgelerde sunulmaz. Yerel Fluke temsilcinize sorun.

      ©2025  Fluke Corporation. Tüm ticari markalar ilgili sahiplerinin mülkiyetindedir. Akıllı telefon, kablosuz ağ hizmeti ve veri planı ücrete dahil değildir. İlk 5 GB depolama alanı ücretsizdir. iOS 8 veya üzeri işletim sistemi çalıştıran iPhone 4s ve üzeri modeller, iPad (iPad'de bir iPhone çerçevesinde), Android 4.3.x veya üzeri işletim sistemi çalıştıran Samsung Galaxy S4 ve Android™ 4.4.x veya üzeri işletim sistemi çalıştıran Samsung Galaxy S, Nexus 5, HTC One ve One M8 ile uyumludur. Apple ve Apple logosu, Apple Inc. şirketinin ABD'de ve diğer ülkelerde kayıtlı ticari markalarıdır. App Store, Apple Inc. şirketinin hizmet markasıdır. Google Play, Google Inc. şirketinin ticari markasıdır.