Fluke 376 FC แคลมป์มิเตอร์ True-RMS พร้อม iFlex

  • 376fc
  • Fluke 376 FC True-rms AC/DC Clamp Meter with iFlex
  • Fluke 376 FC True-rms AC/DC Clamp Meter with iFlex
  • 376 fc contents in box

คุณลักษณะสำคัญ

  • Measures AC current with included 18-inch or 36-inch iFlex current probe
  • VFD low pass filter for accurate measurements of non-linear signals
  • Remotely log, trend and monitor to pinpoint intermittent faults
  • Inrush measurement to filter out noise and capture starting current

ภาพรวมผลิตภัณฑ์: Fluke 376 FC แคลมป์มิเตอร์ True-RMS พร้อม iFlex

The Fluke 376 FC True-rms Clamp Meter with iFlex is the most advanced troubleshooting tool for industrial and commercial electricians. The 376 is part of the Fluke Connect family of wireless test tools that enable you to log, trend and monitor measurements while remaining safely away from the arc flash zone through Bluetooth connectivity.

Find the cause of difficult problems

The 376 FC clamp meter uses an integrated low-pass filter for accurate measurements of non-linear signals, such as adjustable speed drives, electronic ballasts and other non-linear loads. The clamp also uses proprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it.

Measure:

  • Voltage to 1000 V AC or DC
  • Resistance to 60 kΩ with continuity detection
  • Min, max, average, and inrush recording to capture variations automatically
  • 500 mV DC measurement range to interface with other accessories
  • 1000 μF capacitance measurement
  • Work safely and conveniently
  • The 376 FC clamp carries a CAT III 1000 V, CAT IV 600 V safety rating, designed to offer you the highest possible protection in a test tool.

The included 18-inch or 36-inch iFlex flexible current probe provides easier access to large conductors in tight spaces. The flexible probe:

  • Expands the measurement range to 2500 A AC
  • Allows frequency measurement to 500 Hz with body jaw and iFlex

ข้อมูลจำเพาะ: Fluke 376 FC แคลมป์มิเตอร์ True-RMS พร้อม iFlex

General Specifications
AC Current via Jaw
Range999.9 A
Resolution 0.1 A
Accuracy 2% ±5 digits (10 Hz to 100 Hz)
2.5% ±5 digits (100-500 Hz)
Crest Factor (50 Hz/60 Hz)3 @ 500 A
2.5 @ 600 A
Add 2% for C.F. >2
AC Current via Flexible Current Probe
Range2500 A
Resolution0.1 A (≤ 600 A)
1 A (≤ 2500 A)
Accuracy3% ±5 digits (5 – 500 Hz)
Crest Factor (50/60Hz)3.0 at 1100 A
2.5 at 1400 A
1.42 at 2500 A
Add 2% for C.F. > 2
Flexible current probe
 i2500-10 Flexi2500-18 Flexi2500-36 Flex
A   
Distance from Optimum0.5 in (12.7 mm)1.4 in (35.6 mm)4.8 in (122.2 mm)
Error±0.5 %±0.5 %±0.5 %
B   
Distance from Optimum0.8 in (20.3 mm)2.0 in (50.8 mm)5.3 in (133.6 mm)
Error±1.0 %±1.0 %±1.0 %
C   
Distance from Optimum1.4 in (35.6 mm)2.5 in (63.5 mm)5.8 in (147.6 mm)
Error±2.0 %±2.0 %±2.0 %
Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.
DC Current
Range999.9 A
Resolution0.1 A
Accuracy2% ±5 digits
AC Voltage
Range1000 V
Resolution0.1 V (≤600.0 V)
1 V (≤1000 V)
Accuracy1% ±5 digits (20 Hz to 500 Hz)
DC Voltage
Range1000 V
Resolution0.1 V (≤600.0 V)
1 V (≤1000 V)
Accuracy1% ±5 digits
mV dc
Range500.0 mV
Resolution0.1 mV
Accuracy1% ±5 digits
Frequency via Jaw
Range5.0 Hz to 500.0 Hz
Resolution 0.1 Hz
Accuracy 0.5% ±5 digits
Trigger level 5 Hz to 10 Hz, ≥10 A
10 Hz to 100 Hz, ≥5 A
100 Hz to 500 Hz, ≥10 A
Frequency via Flexible Current Probe
Range5.0 Hz to 500.0 Hz
Resolution 0.1 Hz
Accuracy 0.5% ±5 digits
Trigger level 5 Hz to 20 Hz, ≥25 A
20 Hz to 100 Hz, ≥20 A
100 Hz to 500 Hz, ≥25 A
Resistance
Range60 kΩ
Resolution0.1 Ω (≤600 Ω)
1 Ω (≤6000 Ω)
10 Ω (≤60 kΩ)
Accuracy1% ±5 digits
Capacitance
Range1000 μF
Resolution0.1 μF (≤ 100 μF)
1 μ F (≤ 1000 μF)
Accuracy1% ±4 digits
Mechanical Specifications
Maximum voltage between any terminal and earth ground1000 V
Batteries2 AA, NEDA 15A, IEC LR6
Operating temperature-10 °C to +50 °C
Storage temperature-40 °C to +60 °C
Operating humidity -
non-condensing (< 10°C)
≤90% RH (at 10 °C to 30 °C)
≤75% RH (at 30 °C to 40 °C)
≤45% RH (at 40 °C to 50 °C)
Operating altitude2000 m
Storage altitude12,000 m
Size (L x W x H)249 x 85 x 45 mm
Weight395 g
Jaw opening34 mm
Flexible current probe diameter7.5 mm
Flexible current probe cable length
(head to electronics connector)
1.8 m
SafetyIEC 61010-1, Pollution Degree 2
IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V
IEC 61010-2-033:CAT III 1000 V / CAT IV 600 V
  
IP ratingIEC 60529: IP30, non-operating
Radio Frequency Certification FCC IDT68-FBLE IC:6627A-FBLE
Electromagnetic Compatibility (EMC)
InternationalIEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2
CISPR 11: Group 1, Class A
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.
Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purpose. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object.
Korea (KCC)Class A Equipment (Industrial Broadcasting & Communication Equipment)
Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
USA (FCC)47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Temperature coefficientsAdd 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C

รุ่น: Fluke 376 FC แคลมป์มิเตอร์ True-RMS พร้อม iFlex

Fluke 376 FC

Fluke 376 FC แคลมป์มิเตอร์ True-RMS


ซื้อเลย

รวม:

  • Fluke 376 FC แคลมป์มิเตอร์ True-RMS พร้อม iFlex
  • โพรบวัดความยืดหยุ่นiFlex®ขนาด 18 นิ้ว
  • สายรัดแม่เหล็ก TPAK
  • การทดสอบลีด TL75
  • แบตเตอรี่ AA สองก้อน (ติดตั้งแล้ว)
  • กระเป๋าหิ้วนุ่ม
  • บัตรคำแนะนำการเคลือบ
  • เอกสารข้อมูลความปลอดภัย

Fluke Connect อาจไม่มีให้บริการในบางประเทศ

*เครื่องมือบางรุ่นสามารถใช้ได้ในบางประเทศ โปรดตรวจสอบกับตัวแทนจำหน่ายของ Fluke ที่อยู่ใกล้บ้าน

©  Fluke Corporation เครื่องหมายการค้าทั้งหมดเป็นกรรมสิทธิ์ของผู้ที่เป็นเจ้าของ การให้บริการไร้สายและข้อมูลผ่านสมาร์ทโฟนไม่รวมอยู่ในการสั่งซื้อ พื้นที่เก็บข้อมูล 5 GB แรกให้บริการฟรี เข้ากันได้กับ iPhone 4s ขึ้นไปที่ใช้ระบบปฏิบัติการ iOS 8 หรือสูงกว่า; iPad (ในกรอบ iPhone บน iPad); Samsung Galaxy S4 ที่ใช้ระบบปฏิบัติการ Android 4.3.x หรือสูงกว่า และ Samsung Galaxy S, Nexus 5, HTC One และ HTC One M8 ที่ใช้ระบบปฏิบัติการ Android™ 4.4.x หรือสูงกว่า Apple และโลโก้ Apple เป็นเครื่องหมายการค้าของ of Apple Inc. ที่จดทะเบียนในสหรัฐอเมริกาและประเทศอื่นๆ App Store เป็นเครื่องหมายบริการของ Apple Inc. และ Google Play เป็นเครื่องหมายการค้าของ Google Inc.