Fluke P5510-2700G, P5513-2700G Pneumatic Pressure Calibrators
āļāļļāļāļĨāļąāļāļĐāļāļ°āļŠāļģāļāļąāļ
- 0.02% full scale accuracy per 2700G Gauge.
- Adaptors for NPT, BSP, and metric fittings.
- Expandable lower range with additional gauges.
- Battery-operated gauges with line power capability.
āļ āļēāļāļĢāļ§āļĄāļāļĨāļīāļāļ āļąāļāļāđ: Fluke P5510-2700G, P5513-2700G Pneumatic Pressure Calibrators
āļāđāļ§āļāđāļĢāļāļāļąāļ 0 āļāļķāļ 300 psi (20 āļāļēāļĢāđ)
āļāđāļ§āļāļŠāļļāļāļāļēāļāļēāļĻ 0 āļāļķāļ 24 inHg (800 mbar)
āļāđāđāļĄāļāļāļŠāļāļāđāļāļĢāļĩāļĒāļāđāļāļĩāļĒāļāļāļīāļ§āđāļĄāļāļīāļāđāļāđāļĢāļąāļāļāļēāļĢāļāļāļāđāļāļāļĄāļēāđāļāļ·āđāļāļāļāļŠāļāļāđāļāļĢāļ·āđāļāļāļĄāļ·āļāļāļēāļĢāļ§āļąāļāđāļĢāļāļāļąāļāļāļąāļāđāļāļĢāļ·āđāļāļāļĄāļ·āļāļāļēāļĢāļāļāļŠāļāļāļŦāļĨāļąāļ āđāļāļĢāļ·āđāļāļāļĄāļ·āļāļāļĩāđāļāļļāđāļĄāļāđāļēāļāļĩāđāļĄāļĩāļāļēāļĢāļāļ§āļāļāļļāļĄāļāļĩāđāđāļĄāđāļāļĒāļģāļŠāļģāļŦāļĢāļąāļāļāļ§āļēāļĄāļāđāļāļāļāļēāļĢāļāđāļēāļāļāļēāļĢāļŠāļāļāđāļāļĩāļĒāļāļāļĩāđāļŠāļģāļāļąāļāđāļĨāļ°āļĄāļĩāļāļļāļāļŠāļĄāļāļąāļāļīāļĄāļēāļāļĄāļēāļĒāļāļĩāđāļāļāđāļāđāļāļĢāļ·āđāļāļāļĄāļ·āļāļāļāļŠāļāļāļāđāļģāļŦāļāļąāļāļāļīāļ§āđāļĄāļāļīāļāļĒāļāļāļāļīāļĒāļĄāļāļāļāđāļĢāļē
āļāļļāļāļŠāļĄāļāļąāļāļī
- āđāļĢāļāļāļąāļ/āļŠāļļāļāļāļēāļāļēāļĻāļāļđāđ
- āļāļēāļĢāļāļāļāđāļāļāļŠāļģāļŦāļĢāļąāļāļāļēāļĢāļāļīāļāļāļąāđāļāļāļāđāļāđāļ°
- āļāļąāđāļĄāļĄāļ·āļāđāļāļāļāļīāļāļāļąāđāļāđāļāļāļąāļ§āđāļāđāļāđāļŦāļĨāđāļāļāđāļēāļĒāđāļĢāļāļāļąāļ/āļŠāļļāļāļāļēāļāļēāļĻ
- āļāļĩāļāđāļāļīāļĨāļ§āļēāļĨāđāļ§āļāļļāļāļ āļēāļāļŠāļđāļāļŠāļģāļŦāļĢāļąāļāļāļēāļĢāļāļ§āļāļāļļāļĄāđāļāļĒāļĨāļ°āđāļāļĩāļĒāļ
- āļāļąāļ§āđāļāļĨāļāļāļāļĢāđāļāļāļāļŠāļāļāļāļķāđāļāđāļĄāđāļāđāļāļāđāļāđāđāļāļ PTFE āļŦāļĢāļ·āļāļāļĢāļ°āđāļ
āļāđāļāļĄāļđāļĨāļāļģāđāļāļēāļ°: Fluke P5510-2700G, P5513-2700G Pneumatic Pressure Calibrators
Calibrator Model | Range | 1 Year Specification |
P5510-2700G-1 | -12 to 300 psi (-80 kPa to 2 MPa) | Pressure: Âą0.06 psi (Âą0.4 kPa) Vacuum: Âą0.15 psi (Âą1 kPa) |
P5510-2700G-3 | -12 to 300 psi (-80 kPa to 2 MPa) | Pressure: Âą0.06 psi (Âą0.4 kPa) Vacuum: Âą0.15 psi (Âą1 kPa) |
-12 to 100 psi (-80 kPa to 700 kPa) | Pressure: Âą0.02 psi (Âą0.14 kPa) Vacuum: Âą0.05 psi (Âą0.35 kPa) | |
-15 to 15 psi (-100 kPa to 100 kPa) | Pressure: Âą0.003 psi (Âą0.02 kPa) Vacuum: Âą0.0075 psi (Âą0.05 kPa) | |
P5513-2700G-1 | 0 to 3 000 psi (0 to 20 MPa) | Pressure: Âą0.6 psi (Âą0.004 MPa) |
P5513-2700G-3 | 0 to 3 000 psi (0 to 20 MPa) | Pressure: Âą0.6 psi (Âą0.004 MPa) |
-12 to 1 000 psi (-80 Kpa to 7 MPa) | Pressure: Âą0.2 psi (Âą0.0014 MPa) Vacuum: Âą0.5 psi (Âą3.5 kPa) | |
-12 to 1000 psi (-80 kPa to 7 MPa) | Pressure: Âą0.02 psi (Âą0.14 kPa) Vacuum: Âą0.05 psi (Âą0.35 kPa) | |
Media compatibility: Note 1: Any clean, dry non-corrosive gas Note 2: Any liquids or gases compatible with 316 stainless steel Note 3: Any non-flamable, non-toxic, non-explosive, non-oxidizing liquid or gas compatiable with 316 stainless steel | ||
Specifications for P5510-2700G | ||
Pressure Range | 0 to 300 psi (20 bar) | |
Test Port Adapters | (2 sets) 1/8, 1/4, 3/8 and 1/2 NPT or BSP | |
Instrument Size (W x D x H) | 9.5x 13 x 7 in (240 x 330 x 180 mm) | |
Instrument Weight | 7.5 lb (3.5 kg) | |
Vacuum Range | 0 to 24 inHg (800 mbar) | |
Specifications for P5513-2700G | ||
Pressure Range | 0 to 3000 psi (210 bar) | |
Test Port Adapters | (2 sets) 1/8, 1/4, 3/8 and 1/2 NPT or BSP | |
Instrument Size (W x D x H) | 17.5 x 12 x 8.5 in (440 x 300 x 215 mm) | |
Instrument weight | 17 lb (8 kg) | |
Gas Supply Connection | 1/4 NPT female |
āļĢāļļāđāļ: Fluke P5510-2700G, P5513-2700G Pneumatic Pressure Calibrators
āļāļđāđāļĄāļ·āļāđāļĨāļ°āđāļŦāļĨāđāļāļāđāļāļĄāļđāļĨ: Fluke P5510-2700G, P5513-2700G Pneumatic Pressure Calibrators
- 2700G | āļāļđāđāļĄāļ·āļāļāļđāđāđāļāđ
- P5510 | āļāļđāđāļĄāļ·āļāļāļđāđāđāļāđ
- P5513 | āļāļđāđāļĄāļ·āļāļāļđāđāđāļāđ
- 2700G | āđāļāļāļŠāļēāļĢāđāļāļ·āđāļāļāļ§āļēāļĄāļāļĨāļāļāļ āļąāļĒ
- 2700G | āļāļđāđāļĄāļ·āļāļāļēāļĢāļŠāļāļāđāļāļĩāļĒāļ
- 2700G | āļāļĢāļ°āļāļēāļĻāđāļāļĩāđāļĒāļ§āļāļąāļāļāļ§āļēāļĄāđāļāļĢāļāļąāļāļāļāļāļŦāļāđāļ§āļĒāļāļ§āļēāļĄāļāļģ