Fluke T5-600 and 62 MAX+ Electrical and HVAC Kit

  • Fluke T5-600/62MAX+/1AC II IR Thermometer, Electrical Tester and Voltage Detector Kit

Nyckelfunktioner

  • Automatically measures volts ac and volts dc with precise digital resolution.
  • Displays resistance to 1000?.
  • Easy and accurate OpenJaw™ current measurement.
  • Continuity beeper.
  • Rugged enough to withstand a 10-foot (3m) drop.
  • 600V model.
  • Auto off mode to conserve battery life.
  • AC current.
  • Display hold.
  • All inputs of the T5-600 are protected to EN61010-1 CAT III 600V. UL, CSA and VDE listed.

Fluke 62 MAX+. Small in size. Big on toughness.

  • Dust and water-resistant: IP54 rated.
  • Rugged: 3-meter (9.8-foot) drop tested.
  • Ergonomically designed: Completely redesigned for a more natural hand fit.
  • Distance to spot: 12:1.
  • Dual lasers: Identifies area to be measured.
  • Large, backlit display: Makes data easier to read, even in dark areas.
  • C115 Deluxe Soft Carrying Case with Shoulder Strap.

Produktöversikt: Fluke T5-600 and 62 MAX+ Electrical and HVAC Kit

This kit is designed to help electricians and HVAC technicians solve problems quicker. Test first for overheated electrical devices using an IR thermometer; then use electrical test tools to find out more about the problem.

Specifikationer: Fluke T5-600 and 62 MAX+ Electrical and HVAC Kit

Fluke T5-600 Voltage, Continuity and Current Tester

Specifications
Jaw opening12.9 mm (0.5 in)
Max wire size1/0 THHN Cable
Current range AC rms0 to 100.0 A
Accuracy AC current (50/60 Hz)3% ± 3 counts
AC responseAveraging
Voltage range AC/DC0 to 600 V
Voltage accuracyAC1.5% ± 2 counts
DC1% ± 1 count
Resistance range0 to 1000 Ω
Continuity beeper thresholdOn at < 25 Ω, off at > 400 Ω
Volts indicator LED thresholdGuaranteed on by 30 V AC
Environmental specifications
Operating temperature-10°C to 50°C
Storage temperature-30°C to 60°C
Humidity (without condensation)0% to 95% (5°C to 30°C)
0% to 75% (30°C to 40°C)
0% to 45% (40°C to 50°C)
Dust/water resistanceYes
Operating altitude2000 meters max
Temperature coefficient0.1 x (specified accuracy)/°C (< 18°C or > 28°C)
Safety Specifications
Overvoltage categoryCAT III 600 V AC/DC (EN61010-1)
Agency approvalsUL, CSA, and VDE
Maximum voltageBetween any terminal and earth ground
Mechanical and general specifications
Size30.5 x 51 x 203 mm
Weight300 g
WarrantyTwo-years
Battery life200 hour zinc chloride, 400 hour alkaline
Battery type2 x AA
Low battery indicatorYes
Current sensor opening12.9 mm
Calibration cycle1 year
Test leadsTypeHeavy duty, flexible leads rated for 1000 V use.
Field replaceable leads terminate in male shrouded banana plugs
ProbesOne red, one black.
Detachable Slim-Reach™ probe tips
StylesTP1 Slim Reach™ Test Probes

Fluke 62 MAX+ Infrared Thermometer

Specifications
Temperature range-30°C to 650°C (-22°F to 1202°F)
Accuracy±1.0°C or ±1.0% of reading, whichever is greater
-10°C to 0°C: ±2.0
-30°C to -10°C: ±3.0
Response time (95%)< 500 ms (95% of reading)
Spectral response8 to 14 microns
Emissivity0.10 to 1.00
Optical resolution12:1 (calculated at 90% energy)
Display resolution0.1°C (0.2°F)
Repeatability of readings±0.5% of reading or <±0.5°C (1°F), whichever is greater
PowerAA battery
Battery life8 hours with laser and backlight on
Physical specifications
Weight255 g (8.99 oz)
Size175 x 85 x 75 mm (6.88 x 3.34 x 2.95 in)
Operating temperature0°C to 50°C (32°F to 122°F)
Storage temperature-20°C to 60°C (-4°F to 140°F), (without battery)
Operating humidity10% to 90% RH non-condensing at 30°C (86°F)
Operating altitude2000 meters above mean sea level
Storage altitude12,000 meters above mean sea level
IP ratingIP 54 per IEC 60529
Drop test3 meters
Vibration and shockIEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms
EMCEN 61326-1:2006 EN 61326-2:2006
Standards and agency approvalComplianceEN/IEC 61010-1: 2001
Laser safetyFDA and EN 60825-1 Class II