Kit combinado de AVAC para Termómetro visual IR VT04
Indisponível
Características principais
VT04 Visual IR Thermometer features:
- Unlimited applications – See data sheet for powerful applications and details
- Built-in digital camera – Every Fluke Visual IR Thermometer has a built-in digital camera
- Exclusive thermal heat map blending overlay – With one button, blend digital images and thermal heat maps to instantly show the exact location of the issue
- No training required - Fully automatic with built-in intelligence
- True pocket size design – Less than half the size of an average infrared camera
- SmartView® reporting software – Store up to 10,000 images per Gb on included SD card and make professional reports on included professional software
- Automatic hot and cold spot trackers
- Breakthrough affordability – Fraction of the cost of infrared cameras that require costly training and software
- Powerful resolution with PyroBlend® Plus optics:
- Best-in-class field of view: 28 ° x 28 ° (40% wider for tight spaces)
- 4 times sharper images
- Alarm and time lapse features:
- Hi/Lo temperature alarm– Find hot spots in seconds with the alarm feature
- Time lapse image capture– Automatically monitor equipment over time
- Automated monitoring alarm – Automatically capture images after an alarm has been triggered
902 HVAC Clamp Meter features:
- Designed for HVAC applications with capacitance, DC Current (µA), and temperature measurements
- Small body and jaws fit perfectly in your hand and into tight places
- Handy 'Display Hold' button keeps measurements on the display
- Meter controls are positioned so current measurements can be done with one hand (index finger on clamp opening lever and thumb on rotary switch)
- Large, backlit display is easy-to-see in less than ideal conditions
- Auto shut-off maximizes battery life so the meter works when you need it
- Three year warranty
116 Digital Multimeter features:
- Built-in thermometer for HVAC applications
- Microamps to test flame sensors
- Low input impedance: helps prevent false readings due to ghost voltage
- Large white LED backlight to work in poorly lit areas
- Resistance, continuity, frequency and capacitance
- Min/Max/Average with elapsed time to record signal fluctuations
- Compact ergonomic design for one-handed operation
- Compatible with optional magnetic hanger (ToolPak™)
- CAT III 600 V safety rated
Indisponible. Consulte seu distribuidor.
A Fluke sugere:Termómetro visual IR Fluke VT04
Descrição do produto: Kit combinado de AVAC para Termómetro visual IR VT04
Poupe dinheiro e adquira o VT04, a pinça amperimétrica Fluke 902 e o multímetro digital Fluke 116. Em conjunto, estas ferramentas permitem que os técnicos de AVAC procedam à detecção de avarias e ao diagnóstico dos problemas mais difíceis de resolver.
Especificações: Kit combinado de AVAC para Termómetro visual IR VT04
Termómetro visual IR Fluke VT04
Características principais | |
Câmara digital incorporada | Sim |
Sobreposição de mapa térmico | Sim, cinco modos de combinação |
Sistema óptico de imagens | Sistema óptico PyroBlend® Plus *imagens 4x mais nítidas do que com o Fluke VT02 |
Campo de visão | 28° x 28° |
Alarmes de temperatura alta/baixa | Sim |
Captura de imagens no tempo decorrido | Sim |
Alarme de monitorização automática | Sim |
Tipo de bateria | Recarregável de iões de lítio |
Formação | Não requer formação |
Ergonomia | Design elegante e de tamanho de bolso |
Marcadores de pontos quentes e frios | Sim |
Características gerais | |
Autonomia das pilhas | Oito (8) horas |
Gama de medição de temperatura | -10 °C a +250 °C (14 °F a 482 °F) |
Precisão de medição de temperatura | +/- 2 °C ou +/- 2% |
Medição de temperatura | Sim, ponto central |
Suporte de armazenamento (cartão microSD) | Armazenamento até 10 000 imagens por GB (cartão de quatro [4] GB incluído] |
Banda espectral de infravermelhos | 6,5 µm a 14 µm |
Nível e alcance | Auto |
Mecanismo de focagem | Sem focagem, não é necessária formação (inteligência incorporada) |
Opções de focagem - opções NEAR/FAR exclusivas e seleccionáveis pelo utilizador | NEAR < 23 cm (9 pol.); FAR > 23 cm (9 pol.) |
Dimensões | 21 cm x 7,5 cm x 5,5 cm (8,3 pol. x 3 pol. x 2,2 pol.); < 350 g (12,5 oz.) |
Formato de ficheiro | Formato .is2 guardado no cartão SD. O utilizador pode criar relatórios profissionais ou exportar imagens no SmartView (BMP, DIB, GIF, SPE, FIF, SPEG, JPG, PNG, TIF e TIFF) |
Segurança e conformidade | CFR47: 2009 Classe A. Parte 15 subparte B; CE: EN 61326:2006; IEC/EN 61010-1:2010 |
Garantia | Dois (2) anos |
Pinça amperimétrica True-RMS AVAC Fluke 902
Especificações | ||
Tensão DC | Gama | 0 – 600,0 V |
Precisão | 1% ± 5 contagens | |
Tensão AC (True-RMS) | Gama | 0 – 600,0 V |
Precisão | 1% ± 5 contagens (50/60 Hz) | |
Corrente AC (True-RMS) | Gama | 0 – 600,0 A |
Precisão | 2,0% ± 5 contagens (50/60 Hz) | |
Corrente DC | Gama | 0 - 200,0 µA |
Precisão | 1,0% ± 5 contagens | |
Resistência | Gama | 0 – 9999 Ω |
Precisão | 1,5% ± 5 contagens | |
Continuidade | <= 30 Ω | |
Temperatura* (termopar tipo K) | Gama | -10 graus C a 400 graus C (-14 graus F a 752 graus F) |
Precisão | +/- 1,0% + 0,8 graus C (+/- 1,0% + 1,5 graus F) típico | |
Gama | -40 graus C a -10 graus C (-40 graus F a -14 graus F) | |
Precisão | +/- 5,0% + 1,5 graus C (+/- 5,0% + 3,3 graus F) típico | |
Capacitância | Gama | 1-1000 µF |
Precisão | 1,9% ± 2 contagens |
* Erro não inclui erros de termopar tipo K
Especificações mecânicas e gerais | |
Peso | 0,7 kg (1,5 lb) |
Dimensões | 27,3 x 10,8 x 6,2 cm (10,75 x 4,25 x 2,44 pol.) |
Tipo de bateria | Pilhas alcalinas AA (2) |
Multímetro digital Fluke 116
Especificações | |
Tensão máxima entre qualquer terminal e a terra | 600 V |
Protecção contra picos | Pico de 6 kV, de acordo com IEC 61010-1 600 V CAT III, grau de poluição 2 |
Display | Digital: 6000 contagens, actualizações 4 vezes por segundo |
Gráfico de barras | 33 segmentos, actualização 32 vezes por segundo |
Temperatura de funcionamento | -10 °C a +50 °C |
Temperatura de armazenamento | -40 °C a +60 °C |
Tipo de bateria | Alcalina de 9 volts, NEDA 1604A/ IEC 6LR61 |
Autonomia das pilhas | 400 horas típicas, sem retroiluminação |
Especificações de precisão | ||
Milivolts DC | Gama/Resolução | 600,0 mV/0,1 mV |
Precisão | ± ([% da leitura] + [contagens]): 0,5% + 2 | |
Tensão DC | Gama/Resolução | 6000 V/0,001 V 60,00 V/0,01 V 600,00 V/0,1 V |
Precisão | ± ([% da leitura] + [contagens]): 0,5% + 2 | |
Detecção automática de volts | Gama/Resolução | 600,0 V/0,1 V |
Precisão | 2,0% + 3 (DC, 45 Hz a 500 Hz) 4,0% + 3 (500 Hz a 1 kHz) | |
milivolts AC ¹True-RMS | Gama/Resolução | 600,0 mV/0,1 mV |
Precisão | 1,0% + 3 (DC, 45 Hz a 500 Hz) 2,0% + 3 (500 Hz a 1 kHz) | |
Volts AC ¹True-RMS | Gama/Resolução | 6000 V/0,001 V 60,00 V/0,01 V 600,0 V/0,1 V |
Precisão | 1,0% + 3 (DC, 45 Hz a 500 Hz) 2,0% + 3 (500 Hz a 1 kHz) | |
Continuidade | Gama/Resolução | 600 Ω/1 Ω |
Precisão | Sinal sonoro ligado a < 20 Ω, desligado a > 250 Ω; detecta circuitos abertos ou curto-circuitos de 500 μs ou superiores. | |
Ohms | Gama/Resolução | 600,0 Ω/0,1 Ω 6000 kΩ/0,001 kΩ 60,00 kΩ/0,01 kΩ 600,0 kΩ/0,1 kΩ 6000 MΩ/0,001 MΩ |
Precisão | 0,9% + 1 | |
Gama/Resolução | 40,00 MΩ/0,01 MΩ | |
Precisão | 5% + 2 | |
Teste de díodos | Gama/Resolução | 2,00 V/0,001 V |
Precisão | 0,9% + 2 | |
Capacitância | Gama/Resolução | 1000 nF/1 nF 10,00 μF/0,01 μF 100,0 μF/0,1 μF 9999 μF/1 μF 100 μF a 1000 μF |
Precisão | 1,9% + 2 | |
Gama/Resolução | >1000 μF | |
Precisão | 5% + 20% | |
Capacitância Lo-Z | Gama | 1 nF a 500 μF |
Precisão | 10% + 2 típico | |
Temperatura² (termopar tipo K) | Gama/Resolução | -40 °C a 400 °C/0,1 °C |
Precisão | 1% + 10² | |
Gama/Resolução | -40 °F a 752 °F/0,2 °F | |
Precisão | 1% + 18² | |
Microamperes AC True-RMS (45 Hz a 500 Hz) | Gama/Resolução | 600,0 μA/0,1 μA |
Precisão | 1,0% + 2 | |
Microamperes DC | Gama/Resolução | 600,0 μA/0,1 μA |
Precisão | 1,0% + 2 | |
Hz (entrada V ou A)² | Gama/Resolução | 99,99 Hz/0,01 Hz 999,99 Hz/0,1 Hz 9,999 Hz/0,001 Hz 50,00 Hz/0,01 Hz |
Precisão | 0,1% + 2 |
Notas:
- Todas as gamas de tensão AC, excepto Auto-V/LoZ, são especificadas a partir de 1% a 100% da gama. Auto-V/LoZ são especificadas a partir de 0,0 V.
- A diferença de temperatura (precisão) não inclui erros da sonda de termopar.
- Acoplamento AC para frequência, 5 Hz a 50 kHz para tensão AC. Acoplamento DC para frequência, 45 Hz a 5 kHz para corrente AC.
- Gama de temperatura/Resolução: -40 °F a 752 °F/0,2 °F.
Especificações mecânicas e gerais | |
Dimensões | 167 x 84 x 46 mm (6,57" x 3,31" x 1,82") |
Peso | 550 g |
Garantia | 3 anos |
Modelos: Kit combinado de AVAC para Termómetro visual IR VT04
Fluke VT04-HVAC-Kit
Fluke VT04 Visual IR Thermometer HVAC Combo Kit
Inclui:
- Termómetro visual IR VT04
- Pinça amperimétrica AVAC True-RMS 902
- Multímetro digital 116 concebido especificamente para profissionais de AVAC