Fluke 6500-2 Portable Appliance Testers

  • Fluke 6500-2 Portable Appliance Tester 1
  • Fluke 6500-2 Portable Appliance Tester
  • Fluke 6500-2 Portable Appliance Tester 3
  • Fluke 6500-2 Portable Appliance Tester 4

Principales fonctions

Fluke Simplifies Portable Appliance Testing

  • Dedicated key for each test for ‘one-touch’ testing
  • Pre-set pass/fail levels to save time
  • Large backlit display for easy reading
  • Single mains socket for appliance connection
  • Separate IEC socket for easy mains/extension lead testing
  • Detachable test leads for quick field replacement
  • Integral carrying handle
  • USB port for data transfer
  • Integral QWERTY keyboard for rapid data entry
  • Additional USB memory capability for back-up data storage and transfer to PC
  • Large backlit graphics display
  • Pre-set, auto-test sequences for user convenience
  • Integral site, location and description codes for faster data processing
  • Memory review facility for more on-site control
  • USB port for data transfer

Présentation du produit: Fluke 6500-2 Portable Appliance Testers

Perform More Tests Each Day

The Fluke 6500-2 PAT tester is a low weight, small size, one-touch solution with redesigned auto-test capabilities to help you increase the number of portable appliance tests completed each day. The 6500-2 is designed to enable you to work faster without compromising test results.

One-Touch Solution…

Pre-set test routines are initiated from a single button. This not only simplifies testing but also facilitates a faster, more efficient way of working. The fully automatic 6500-2 also includes user-definable test routines and a QWERTY keyboard for rapid data entry.

Low Weight…

Weighing approximately 3 kg, the 6500-2 is lightweight and easy to carry when working on-site. The hard rugged carrying case (supplied) not only offers protection during transit but also includes extra storage space for accessories and other tools.

Small Size…

This portable appliance testers is also extremely compact, and has Fluke's traditional ruggedness to be able to withstand working in the field. Packed with all the features you need for testing portable appliances, a Fluke PAT tester is a complete all-in-one solution.

Spécifications: Fluke 6500-2 Portable Appliance Testers

Specifications
Test specificationsThe accuracy specification for the display range is defined as ±(%reading + digit counts) at 23 °C ±5 °C, ≤75% RH.
Between 0 °C and 18 °C and between 28 °C and 40 °C, accuracy specifications may degrade by 0.1 x (accuracy specification) per °C.
The measurement range meets the service operating errors specified in EN61557-1: 1997, EN61557-2: 1997, EN61557-4: 1997, EN61557-6: 1997, DIN VDE0404-2.
Power-on testThe test indicates reversed L-N, missing PE, and measures the mains voltage and frequency.
Display range90 V to 264 V
Accuracy at 50 Hz±(2% + 3 counts)
Resolution 0.1 V
Input impedance      > 1 MΩ // 2.2 nF
Maximum input mains voltage264 V
Earth bond test (Rpe)Display Range0 to 19.99 Ω
Accuracy (after bond test zeroing)±(5% + 4 counts)
Resolution0.01 Ω
Test current200 mA AC -0% +40% into 1.99 Ω
10 A AC ±20% into 25 mΩ at 230 V
Open circuit voltage> 4 V AC, < 24 V AC
Bond test zeroingcan subtract up to 1.99 Ω
Insulation test (Riso)Display range0 to 299 MΩ
Accuracy±(5% + 2 counts) from 0.1 to 300 MΩ
Resolution0.01 MΩ (0 to 19.99 MΩ)
0.1 MΩ (20 to 199.9 MΩ)
1 MΩ (200 to 299 MΩ)
Test voltage500 V DC -0% + 25% at 500 kΩ load or 250 V dc -0% +25% at 250 kΩ load
Test current> 1 mA at 500 kΩ load, < 15 mA at 0 Ω
Auto discharge time< 0.5 s for 1 μF
Max. capacitive loadOperational up to 1 μF
Touch current testDisplay range0 to 1.99 mA AC
Accuracy±(4% + 2 counts)
Resolution0.01 mA
Internal resistance (via probe)2 kΩ
Measuring methodProbe*
Substitute leakage current testDisplay range0 to 19.99 mA AC
Accuracy±(2.5% + 3 counts)
Resolution0.01 mA
Test Voltage100 V AC ±20%
Load/leakage test: load currentDisplay range0 A to 13 A
Accuracy±(4% + 2 counts)
Resolution0.1 A*
Load/leakage test: load powerDisplay range 230 V Mains0.0 VA to 3.2 kVA
Accuracy ±(5% + 3 counts)
Resolution1 VA (0 to 999 VA), 0.1 kVA (>1.0 kVA)*
Load/leakage test: leakage currentDisplay range0 to 19.99 mA
Accuracy±(4% + 4 counts)
Resolution0.01 mA*
PELV testAccuracy at 50 Hz±(2% + 3 counts)
Overload protection300 V rms
Warning threshold25 V rms
RCD test: trip currentOperational error±10%
Nominal30 mA
Accuracy±5%
RCD test: trip timeStandard requirement61557 Part 6; tolerance of rated test current 0% to +10%
Operational error±10%
RCD typeAC general-purpose 30 mA
Display range310 ms
Resolution0.1 ms
Accuracy3 ms
Trip time limit at 100% (30 mA)300 ms
Trip time limit at 500% (150 mA)40 ms
*The appliance under test is energized at mains potential.
 
Environmental specifications
Operating temperature0 to 40 °C
Relative humidityNon condensing <10 °C
95% from 10 to 30 °C
75% from 30 to 40 °C
 
Safety specifications
Safety ratingComplies with EN61010-1 3rd edition
CAT II, 300 V, pol 2
 
Mechanical and general specifications
Size (L x W x H)200 x 275 x 114 mm
Weight3.13 kg
Power supply230 V +10% -15%, 50 Hz ±2 Hz or (6500-2 only: 110V +10% -15%,50 Hz ±2 Hz)
Power consumption (tester)13 W typical (idle)
60 W max. during 25A Bond test
StorageTemperature-10 to 60 °C
Corrosion70 °C @ 95% RH for 5 days max.
Operating altitude0 up to 2000 m
SealingIP-40 (enclosure), IP-20 (connectors)
EMCComplies with EN61326-1, portable
EMI Immunity3 V/m

Modèles: Fluke 6500-2 Portable Appliance Testers

Fluke 6500-2
Fluke 6500-2 Portable Appliance Tester

Acheter
  • Fluke 6500-2 Portable Appliance Tester
  • Quick reference guide
  • Hard carrying case
  • Test lead
  • Test probe
  • Crocodile clip
  • Mains cord
  • USB stick
  • USB cable