PVA-1500 Series PV Analyzer, I-V Curve Tracer

  • PVA-1500 Series PV Analyzer
  • PVA-1500T2 Series PV Analyzer
  • PVA-1500HE Series PV Analyzer Image
  • PVA-1500 Series PV Analyzer
  • PVA-1500 Series PV Analyzer

Características principales

  • Measures and displays I-V curves up to 1500V and 30A, including on high efficiency modules (PVA-1500HE2)
  • Advanced built-in PV model provides immediate PV performance checking
  • Sweep-to-sweep delay of 9 seconds to measure 3.5MW in <1hr
  • Wireless interfaces for faster setup, safer work environment, and freedom of movement during PV troubleshooting
  • Automates data management, analysis, and reporting

Descripción general del producto: PVA-1500 Series PV Analyzer, I-V Curve Tracer

 

Measure your solar PV system performance

The PVA-1500 is a cutting-edge I-V curve tracer kit designed to measure PV system performance. With this high precision testing equipment, you can reliably assess the health and performance of solar modules and arrays, making informed decisions to enhance their output and longevity.

The PVA-1500 kit offers an array of advanced features, including high throughput I-V curve tracing, providing quick and detailed performance data. Its intuitive user interface enables easy navigation and real-time analysis, allowing for immediate identification of potential issues. By pinpointing problems early, you can maximize your solar energy production and minimize downtime.

Comprehensive measurements and efficient analysis

For commissioning, operations, maintenance, and troubleshooting of PV arrays, I-V curve testing is the most complete solar module performance measurement. Quick analysis of curve datasets aids in detecting outliers, and the stored data functions as a baseline for future performance inquiries.

Accurate I-V curve tracing

The PVA measures the I-V (current versus voltage) curve of a PV string or module using a capacitive load. The measurement is typically performed at the string level by connecting directly to the string or at a combiner box using the fuses to select the string under test. The number of I-V curve points can be selected at 100 or 500. Additionally, the PVA generates the P-V (power versus voltage) curve, Isc, Voc, Imp, Vmp, Pmax, fill factor, and performance factor (the ratio of measured to expected maximum power).

Time-saving interface

With a tablet or laptop (Windows only) as the user interface, perform more tests per hour and display the data in multiple, easy to read formats. Save your measurements by touching your customized array tree at the branch you are measuring. The software automatically calculates the expected I-V curve and displays the performance factor.

Advanced High Efficiency PV Testing Capabilities

Accurate measurement of high efficiency modules up to 30A: Highly efficient modules (>19% module efficiency) possess high capacitance, posing a challenge for some I-V curve tracers that may not be able to measure them. The PVA-1500HE2 is uniquely designed to measure all string types, even those with high efficiency modules, up to 30A. Rapid performance in high temperature environments: The PVA-1500HE2 operates with a swift sweep-to-sweep delay of 9 seconds (at Voc < 1350V). This results in the ability to measure 3.5 MW within an hour, even in high-temperature settings where standard curve tracers often fail due to overheating.

SolSensor™ Wireless PV Reference Sensor

The SolSensor™ provides irradiance, module temperature, and array tilt data to the PV model. The model uses this information to predict the I-V curve shape at these operating conditions and to translate the measured curve to standard test conditions. The SolSensor™ clamps to the module frame, automatically orienting the irradiance sensor to the plane-of-array.

The spectral response of the silicon photodiode sensor in the SolSensor™ is corrected for the PV technology under test. Special factors are provided for multi- and mono-crystalline cells as well as cadmium telluride (CdTe) and other thin film technologies. The sensor is temperature compensated and the angular response of each unit is calibrated for rotation and elevation. As a result, the SolSensor™ is accurate over a broad range of technologies, sky conditions, and sun angles, allowing I-V curve measurements earlier and later in the day.

The SolSensor™ provides two external thermocouple inputs for measuring module backside temperatures. Effective cell temperature can also be calculated directly from the measured I-V curve per IEC 60904-5. The PVA’s SmartTemp™ feature, optionally, blends these two methods for best accuracy.

The PVA and SolSensor™ communicate wirelessly with your PC via WiFi with a line-of-sight wireless range of 100m. That means no wires underfoot, quick setup, the ability to move around while troubleshooting strings, and flexibility to measure multiple combiner boxes with a single SolSensor™ setup.

Turn PVA data into key insights, visualizations, and customizable reports

Capture data in the field with the PVA Application and validate the results with the Data Analysis Tool (DAT), a Microsoft Excel™-based solution streamlining the analysis of PVA I-V curve data. It presents analysis results in multiple formats. It compiles key PV parameters in a string table, flags non-conforming strings, and delivers a statistical overview of the entire array. Additionally, it visually combines string I-V curves at the combiner box level, offering a clear depiction of consistency and identifying atypical strings. The tool also generates histograms for PV parameters across the string population, and this data can be added to a customizable report exported as a PDF. The Data Analysis Tool (DAT) can be downloaded for free use with any PVA. Supported languages: English, French, Spanish, German, Italian, Traditional Chinese, Simplified Chinese, and Brazilian Portuguese.

Download the PVA Application and Data Analysis Tool

Training

Fluke offers a variety of training related to PV test and measurement. Training can either be delivered as a virtual on-demand course or as a live online presentation/discussion format with a product expert (may differ regionally).

Discover PVA-1500 Training

Especificaciones: PVA-1500 Series PV Analyzer, I-V Curve Tracer

PVA-1500 Specifications  
 PVA-1500T2PVA-1500HE2
Voltage Range (Voc)20 to 1500V DC
Maximum Current Range (Isc)
Module Efficiency <19%0 to 30A DC
Module Efficiency ≥19%0 to 10A DC0 to 30A DC
Voltage Accuracy (0 °C to 45 °C)±(0.5% ±0.25V)
Current Accuracy (0 °C to 45 °C)±(0.5% ±0.04A)
Power Accuracy (0 °C to 45 °C)±(1.7 % + 1.0 W) (current ≥3 A, module efficiency <19 %)
Voltage Resolution25 mV
Current Resolution2 mA
Measurement Throughput
Sweep-to-sweep delay (@VOC ≤ 1350V)<9 seconds
Max number of I-V sweeps per hour (@VOC ≤ 1350V)400 sweeps/hr
Max megawatts measured per hour3.5 MW/hr
Thermal Capacity
# sweeps at 18 s sweep-to-sweep delayunlimited (25 °C, 77 °F ambient)
550 (45 °C, 113 °F ambient)
# sweeps at 9s sweep-to-sweep delayunlimited (25 °C, 77 °F ambient)
330 (45 °C, 113 °F ambient)
I-V Trace Points100 or 500 (selectable)
I-V Sweep Duration0.05 to 2 seconds (typically 0.2 seconds for PV strings)
Operating Temperature Range0 °C to 45 °C, 32 °F to 113 °F
Storage Temperature Range-20 °C to 65 °C, -4 °F to 149 °F
Operating Humidity<90 % RH, non-condensing. Avoid exposing a cold instrument to warm and humid air as condensation will result. Store the instrument in the same conditions in which the instrument will be used.
Altitude2000 m max
Battery Charging Time6 hr
Battery Run TimeApprox. 8 hrApprox. 7 hr
Safety and RegulatoryCAT III 1500V
IEC 61010-1: Pollution Degree 2
Warning FeaturesOver-voltage, over-current, over-temperature, reverse
polarity
PV ConnectorStaubli MC4-EVO2Banana Jacks
Charging/Charged LEDYes
In-the-field firmware update-readyYes
Interface to Tablet/LaptopWi-Fi interface between user tablet or laptop, I-V unit and
SolSensor™
Weight6.6 kg, 14.55 lb7.3 kg, 16.09 lb
Height43.2 cm, 1.41 ft (including test lead and strain reliefs)53.3 cm, 1.74 ft
Width21.6 cm, 8.50 in
Depth15.2 cm, 5.98 in
PVA-1500 Test Lead and Clip Specifications
Voltage Range0 to 1500V DC
Current Range0 to 30A DC
Temperature0 °C to 45 °C, 32 °F to 113 °F
HumidityMaximum relative humidity of 80% for temperatures up to 31 °C (87.8 °F) decreasing linearly to 50% relative humidity at 40 °C (104 °F)
Pollution Degree2
Altitude2000 m, 6561 ft maximum
Lead Length152 cm, 59.84 in
Lead ColorsPositive=red, negative=black
Manufacturer (Test Leads and Alligator Clips)Staubli
Note: Use only test leads and clips provided by Fluke for the PVA-1500.
  
SolSensor™ Specifications 
Irradiance 
Sensor TypeSilicon photodiode with corrections for temperature, spectral, and angular effects
Measurement Range100 W/m² to 1500 W/m²
Accuracy±2 % when used to predict the performance of well characterized poly- and monocrystalline PV modules with direct irradiance >600W/m²
Resolution1 W/m²
Measurement IntervalTypically, 3.5 s
Temperature
Sensor TypeType K thermocouple, two inputs
Measurement Range0 °C to 100 °C, 32 °F to 212 °F
Accuracy±2 °C, 35.6 °F (not including limits of error of thermocouple)
Resolution0.1 °C, 32.18 °F
Measurement IntervalTypically, 3.5 s
Tilt
Sensor TypeElectronic
Measurement Range0 to 90° from horizontal
Accuracy±2° typical (0 to 45°)
General
Measurement Cynchronization with I-V CurveTypically, <1 s
Wireless Range (open line of sight)100 m, 328 ft 
Operating Temperature Range0 ºC to 45 ºC, 32 ºF to 113 ºF
Storage Temperature Range-20 ºC to 65 ºC, -4 ºF to 149 ºF
Operating Humidity<90% RH, non-condensing. Avoid exposing a cold instrument to warm and humid air as condensation will result. Store the instrument in the same conditions in which the instrument will be used.
Battery Charging Time6 hr
Battery Run Time>16 hr typical use